• 제목/요약/키워드: Korean anterior teeth

검색결과 1,069건 처리시간 0.032초

Clinical factors affecting the longevity of fixed retainers and the influence of fixed retainers on periodontal health in periodontitis patients: a retrospective study

  • Han, Ji-Young;Park, Seo Hee;Kim, Joohyung;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Periodontal and Implant Science
    • /
    • 제51권3호
    • /
    • pp.163-178
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate clinical factors affecting the longevity of fixed retainers and the influence of fixed retainers on periodontal health in periodontitis patients. Methods: In total, 52 patients with at least 2 years of follow-up after periodontal and orthodontic treatment were included in this study. After scaling and root planing, orthodontic treatment with fixed appliances or clear aligners was performed. Fixed retainers with twist-flex stainless steel wires were bonded to the palatal or lingual sides of anterior teeth. Changes in clinical parameters, including the plaque index, gingival index, calculus index (CI), probing pocket depth, and radiographic bone levels, were evaluated before bonding of fixed retainers and at a 12-month follow-up. Cumulative survival rates (CSRs) for retainer failure were evaluated according to sex, site, CI, stage of periodontitis, and the severity of the irregularity with the log-rank test and hazard ratios (HRs). Results: Twelve months after bonding of fixed retainers, improvements were observed in all clinical parameters except CI and radiographic bone gain. The overall CSR of the retainers with a CI <1 at the 12-month follow-up after bonding of fixed retainers was significantly higher than that of the retainers with a CI ≥1 at the 12-month follow-up (log-rank test; P<0.001). Patients with stage III (grade B or C) periodontitis had a higher multivariate HR for retainer failure (5.4; 95% confidence interval, 1.22-23.91; P=0.026) than patients with stage I (grade A or B) periodontitis. Conclusions: Although fixed retainers were bonded in periodontitis patients, periodontal health was well maintained if supportive periodontal treatment with repeated oral hygiene education was provided. Nonetheless, fixed retainer failure occurred more frequently in patients who had stage III (grade B or C) periodontitis or a CI ≥1 at 12-month follow-up after bonding of fixed retainers.

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

  • Yousefi, Faezeh;Shokri, Abbas;Zahedi, Foozie;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.429-438
    • /
    • 2021
  • Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional(3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches' length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements(>0.830) and between observers(>0.801). Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • 치위생과학회지
    • /
    • 제21권4호
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.

Effects of a Prefabricated Functional Orthodontic Appliance on Children with Class II Division 1 Malocclusion

  • So-Youn An;Eun-Hee Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.112-122
    • /
    • 2023
  • Background: This study aimed to evaluate the effect of a prefabricated functional appliance (Myobrace®) on skeletal, dental, and soft tissue components in children with Class II, division 1 malocclusion. Methods: Thirteen patients with Class II, division 1 malocclusion (9 girls and 4 boys; mean age, 8.2±0.9 years at the start and 9.3±1.0 years at the end of the treatment) were treated with Myobrace® for a mean period of 12.9±4.0 months. Patients were instructed to use the appliance daily for 1 hour and overnight while sleeping. A control group of 10 patients with untreated Class II, division 1 malocclusion (3 girls and 7 boys; mean age, 9.0±1.6 years at the start and 10.4±2.1 years at the end of the observation) was included to eliminate possible growth effects. The mean observation period for this group was 17.7±11.2 months. Lateral cephalograms were taken at the start and end of the treatment, and findings from 41 measurements were analyzed using the V-CephTM program. The mean and standard deviation of cephalometric measurements were analyzed using paired and independent sample t-tests. Results: The treatment group showed significant changes in SNB, ANB, maxillary protrusion, ramus height, proclination of upper anterior teeth, interincisal angle, overjet, and upper lip protrusion compared with the control group. However, only decrease in ANB, maxillary protrusion, overjet, upper lip protrusion, and increase in interincisal angle were significantly higher in the treatment group than in the control group. Conclusion: The prefabricated functional appliance induced skeletal, dentoalveolar, and soft tissue changes, resulting in a significant reduction in anteroposterior discrepancy.

Effects of different topical anesthetics on pain from needle insertion and injection, and the influence of anxiety in patients awaiting endodontic treatment

  • Fatih Aksoy;Samet Tosun
    • Restorative Dentistry and Endodontics
    • /
    • 제47권3호
    • /
    • pp.25.1-25.11
    • /
    • 2022
  • Objectives: This study aimed to evaluate the effects of 5% lidocaine and 2.5% lidocaine/2.5% prilocaine topical anesthetic on pain during needle insertion and infiltration injection in the labial mucosa of anterior maxillary teeth, and to assess the relationship between patients' anxiety and pain scores. Materials and Methods: The Modified Dental Anxiety Scale questionnaire was applied and recorded. Patients were randomly divided into 4 groups (n = 30), as follows: G1 group: 5% lidocaine and placebo for 1 minute, G2 group: 2.5% lidocaine/2.5% prilocaine and placebo for 1 minute, G3 group: 5% lidocaine and placebo for 3 minutes, and G4 group: 2.5% lidocaine/2.5% prilocaine and placebo for 3 minutes. Before the application of topical anesthesia, one side was randomly selected as the topical anesthesia and the contralateral side as the placebo. The pain levels were measured with Visual Analog Scale (VAS) immediately after needle insertion and injection and were compared. The correlation between anxiety and pain scores was analyzed. Results: Administration of 5% lidocaine for 1 minute had significantly higher pain scores for both insertion and infiltration injection than the other groups (p < 0.05). There was a significant moderate positive correlation between dental anxiety and the injection-induced VAS pain score in the placebo side in all groups (p < 0.05). Conclusions: Topical anesthetics significantly reduced the pain caused by both needle insertion and injection pain in comparison to the placebo side. The pain scores of patients with dental anxiety were lower on the topical anesthesia compared to the placebo side.

다수의 치아 상실로 인해 교합수직고경의 감소와 부정확한 발음을 가진 환자의 발음평가를 동반한 전악 수복 증례 (Full mouth rehabilitation accompanied by phonetic analysis of a patient with reduction of vertical dimension of occlusion, and inaccurate pronunciation due to numerous tooth loss: a case report)

  • 박지영;김종진;백진;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제39권3호
    • /
    • pp.119-132
    • /
    • 2023
  • 치아 상실로 인한 구치부의 지지 상실은 전치부의 보상성 정출 및 순측경사 이동으로 이어질 가능성이 존재하고, 이에 따른 과개교합 및 교합수직고경의 감소를 동반할 수 있다. 환자는 저작효율의 감소와 더불어 부정확한 발음과 안모의 변화, 턱관절의 기능 장애를 겪을 가능성이 있으므로 구치부의 지지와 교합수직고경의 회복을 통해 안정적인 교합 형성의 필요성이 있다. 본 증례는 다수의 치아 상실로 인해 수직고경이 감소하여 부정확한 발음을 가진 환자를 대상으로 발음분석을 동반하여 수직고경을 증가시켜 완전 구강 회복술을 시행하였으며 기능적, 심미적으로 만족할 만한 결과를 얻었기에 보고하고자 한다.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

유전치 기성 크라운의 형태 및 치질 삭제량 비교 (Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns)

  • 김소영;임유진;이상호;이난영;지명관
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.64-75
    • /
    • 2019
  • 이 연구의 목적은 임상에서 많이 사용되고 있는 3종의 기성 크라운 즉, 레진관, 레진피복 금속관, 지르코니아 크라운의 크기와 형태를 3차원적으로 계측하여 자연치와 비교함으로써 기성 크라운의 크기 선택과 치질 삭제량에 대한 지침을 얻고자 하는데 있다. 300개의 유전치 석고모델과 3종의 기성 크라운을 대상으로 3D 스캐너와 컴퓨터 이미지 프로그램으로 3차원적 모델을 만들었다. 3차원 모델에서 치관의 근원심 너비, 치관 높이, 치관 ratio, 순면의 곡률반경 등 4가지 평가 척도에 의해 각 기성 크라운별로 한국인 자연치 표준모형과 가장 유사한 형태를 고르고 이를 기준으로 치질 삭제량을 비교, 평가하였다. 유중절치의 경우 기성 크라운별로 레진피복 금속관은 2번, 지르코니아 크라운은 1번, 레진관은 2번이, 유측절치의 경우 레진피복 금속관은 3번, 지르코니아 크라운은 2번, 레진관은 3번이 가장 유사한 형태를 보였다. 치아 삭제량은 상악 유중절치와 유측절치에서 같은 양상을 보였다. 절단연에서는 지르코니아 크라운의 삭제량이 가장 컸다. 인접면은 지르코니아 크라운과 레진관이 비슷한 삭제량을 보였으며 레진피복 금속관에 비해서 컸다. 순면 역시 지르코니아 크라운이 유중절치와 유측절치에서 삭제량이 가장 컸다. 설면의 경우 순면에 비해 전체적으로 삭제량이 적었으며 3종류의 기성 크라운 간에 삭제량 차이도 크지 않았다. 크라운의 형태를 비교하기 위한 4가지 평가 척도 중 치관의 근원심 너비가 기성 크라운의 크기를 선택하는데 가장 중요한 척도로 나타났다.

III급 부정교합자의 이부형태와 두개안면형태의 연관성 (The relationship between the morphology of mandibular symphysis and the craniofacial morphology in class III malocclusion)

  • 김상두;권오원;성재현
    • 대한치과교정학회지
    • /
    • 제26권5호
    • /
    • pp.509-522
    • /
    • 1996
  • 하악골 성장양상이 진단과 치료, 치료후 예후에 특히 중요한 III급 부정교합자에 있어 그 성장양상을 예측하는데 도움을 주고자 사춘기 전으로 생각되는 남자 10-12세군(G1군)과 악골성장이 거의 끝난 것으로 생각되는 성인으로 남자 20세 이상군(G2군)에 대하여 각각 이부비율에 따라 다시 3군으로 분류하고 이부형태와 두개안면형태의 연관성을 연구 한 결과 다음과 같은 결론을 얻었다. 1. 평균 이부비율에 있어 G2군이 G1군에 비해 통계학적으로 유의성 있게 크게 나타났다(p<0.05). 2. G1군과 G2군 모두 이부비율과 두개저 계측항목과는 상관성이 없었다(P>0.05). 3. 상하악골의 수평적 관계 계측항목에서 G1군과 G2군 모두 이부비율과 상악골 계측항목과는 상관성이 없었다(p>0.05). 또한 G1군과 G2군 모두 L, A, S군간 하악의 전후적 위치는 뚜렷한 차이가 없고, 단지 G1군의 Y-axis angle에서 L군이 S군에 비해 크고 G2군은 Pog to Na perp.에서 S군이 L군에 비해 통계학적으로 유의성 있게 크게 나타났다(p<0.05). 4. 하악골의 형태 계측항목에서 gonial angle은 G1군과 G2군 모두 이부비율이 클 수록 수치적으로 증가하나 통계학적인 유의성은 없었다(p>0.05). Lower genial angle과 chin angle은 G1군에서 L군과 A군이 S군보다 통계학적으로 유의성 있게 크게 나타났다(p<0.05). 5. 안면의 수직적 관계 계측항목에서 G1군은 L군이 S군에 비해 전안면고경, 전하안면고경이 통계학적으로 유의성 있게 크며(p<0.05) 하악골이 하방성장한 경향을 보여주었다. 6. 치아의 위치 및 경사도 계측항목에서 G1군은 하방성장을 많이 한 L군이 S군에 비해 상하악 치아들이 정출되어 있는 경향을 보여주었지만 G2군은 단지 하악치아 만이 그러한 경향이 있었다. 7. 이부비율과 다른 계측항목과의 상관분석에서 G1군은 chin angle, PP/MP angle, ANS-Me등 많은 계측항목에서 G2군은 단지 MP-LIT와 MP-LMMC에서 통계학적으로 유의성 있는 상관성을 보였다(p<0.05, p<0.01). 이상을 종합하면 어린 남자군인 G1군에서는 이부비율이 큰 군(L군)과 작은 군(S군)사이에 수평적 골격관계는 차이가 없으나 수직적 골격관계는 L군이 S군에 비해 하악골이 하방으로 많이 성장한 경향을 보여주었다. 하지만 성인 남자군인 G2군에서는 이부비율에 따른 안면골격의 뚜렷한 형태적 차이를 보여주지 않았다.

  • PDF

아동의 하악골에 발생한 복합 치아종의 외과적 처치에 관한 증례보고 (DIFFERENT WAYS OF SURGICAL MANAGEMENT FOR CHILDREN WITH CONFOUND ODONTOMA IN THE MANDIBLE)

  • 정우성;최영철;이긍호
    • 대한소아치과학회지
    • /
    • 제26권3호
    • /
    • pp.499-506
    • /
    • 1999
  • 악골에서 비교적 흔한 빈도로 발생하는 치아종은 치배조직의 과성장으로 인하여 발생한다. 세계보건기구에서는 치아종을 복잡 치아종과 복합 치아종으로 구분하고 있다. 치아종은 악골내 모든 부위에서 발생할 수 있지만 치아와 유사한 복합 치아종은 비교적 상악 전치부에 호발하고, 불규칙한 형태를 나타내는 복잡 치아종은 하악 구치부에 호발한다. 치아종의 원인은 정확히 알려져 있지 않으며 치배에 대한 국소적인 외상이나 감염이 주된 요인으로 추측되고 있고, 최근에는 유전적인 원인에 대해서도 연구되고 있으나 아직 확실히 입증되지는 않고 있다. 일반적인 증상이 없기 때문에 일상적인 방사선 검사에서 주로 발견되고 영구치의 맹출지연이나 유치의 만기잔존 등의 증상이 있을 수 있다. 치아종은 구강내의 어떤 부위에서도 발생이 가능하고 드물기는 하지만 상악동, 하악의 하연, 하악지 및 하악과두 하방에서 발견되기도 하며, 이공 부위에서 발생되는 경우도 있다. 치아종은 발육중인 치열과 악궁에 미치는 영향을 최소화하기 위하여 발견되는 즉시 낭포 및 주위 연조직을 함께 외과적으로 제거하는 것이 바람직하다. 환자의 연령과 치과치료에 대한 협조도, 영구치열의 발육상태, 치아종의 악골내 위치 및 동시적인 치과치료가 요구되는 가를 고려하여 외래 진료실에서 하는 경우도 있고 전신마취를 통하여 하는 경우도 있다. 본 증례는 치아종의 악골내 위치가 깊지 않고 치과치료에 대한 협조도가 양호하다고 판단되는 환아에서는 외래 진료실에서 국소마취하에 수술하여 치료하였고, 연령이 어리고 치아종의 악골내 위치가 깊어 장시간의 시술 시간이 요구되고 동시에 보존적인 치과치료가 필요한 환아에서는 전신마취하에 치료한 것을 보고한 것이다. 두 증례에서 수술 4개월 후 외과적 결손 부위에 골이 형성되었고, 매복된 영구치의 맹출이 정상적으로 이루어진 것으로 나타났다.

  • PDF