• Title/Summary/Keyword: Korea National Housing Corporation

Search Result 179, Processing Time 0.033 seconds

A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction (평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Young-Seok;Kim, Sun-Gu;Baek, Seung-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF

A Hydrologic Analysis for the Infiltration Storages Planned on Jeju-do (제주도에 계획된 침투저류지의 수문학적 분석 사례)

  • Lee, Sangho;Lee, Jungmin;Kang, Taeuk;Kang, Shinuk
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1040-1048
    • /
    • 2010
  • An infiltration storage can be installed as a method of reducing runoff from catchment and increasing stream flow during the dry period by recharging groundwater. However, there is no proper model and method that can be used to design storage capacity of an infiltration storage in Korea. The purpose of the study is to evaluate capacities of infiltration storages planned on Jeju-do in Korea by modifying Storm Water Management Model (SWMM). The basic equations for the infiltration storage are same as those of the infiltration trench used in MIDUSS. Infiltration rates of the infiltration storages were first measured by double ring infiltrometers, and then the modified model was applied to evaluate adequacy for the capacities of three infiltration storages planned on Jeju-do in Korea. The application results show that the two infiltration storages with higher infiltration rates have adequate capacities to infiltrate the total water inflow to the storages. However, the other infiltration storage with lower infiltration rates has not sufficient capacity to infiltrate the total water inflow to the storage and release occurs to the downstream region. The simulation model and method applied can be used for capacity evaluation of future infiltration storages on highly pervious areas in Jeju-do.

A Study on Accident Pattern of Distributing Cable Termination Considering PL Law Environment (PL법 환경을 고려한 배전 케이블 종단부의 사고 유형 연구)

  • Baek, Seung-Myeong;Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Young-Seok;Kim, Sun-Gu;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.319-322
    • /
    • 2008
  • This paper introduces experimental investigates of an accident pattern for the distributing XLPE cable terminations considering PL law environment. The influence of defects such as thickness and length decrease of XLPE, the impurity on XLPE and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness and length decrease of XLPE decrease ac breakdown strengths. Dielectric breakdown traces of XLPE that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of XLPE seriously.

  • PDF

A Study on the Merging Typology of Two Adjacent Dwelling Units for the Reuse of Stock Housing -focused on the 15 pyung Apartment Constructed by KNHC, Naju, Korea- (재고아파트 재활용을 위한 2戶1住宅 수평병합 유형연구 - 나주 주공아파트 15평형을 대상으로 -)

  • 손승광;조순철;이화숙
    • Journal of the Korean housing association
    • /
    • v.10 no.1
    • /
    • pp.51-61
    • /
    • 1999
  • Small apartment housings in Korea are dissatisfied due to the growing areas and changing lifestyle of the residents. Many of them currently confronted with slum areas and kinds of housing stock accumulated much more in Korean contexts. An extention of the existing small houses could be an adaptation model to the increasing requirement standards of the house residents. The new model could support diverse identification of the dwelling model in a settlement and many residents could be satisfied with the settlement. This paper deals with the unification typology of two dwelling units to one in order to remodel existing small apartment houses on the 15-pyung areas (N type) constructed by Korea National Housing Corporation in Naju. The proposed type of the merging of the dwellings remove concrete panel walls, make a path through balcony and attach a living areas to the front of the houses in order to make a circulation between the dwellings. A stair hall can be located in-between or inside the merged houses. It can also enhance privacy against conflictive activities in a house and possibly provide space appropriate for three-generation living. It can be devided for the multi-family use. Finally, the merging types of two dwelling units into one can be used as a device to get rid of the monotonous characteristics and gain diversity in the declining stock housing.

  • PDF

Strategies for Acceleration of Damaged Area Restoration Project in the Development Restriction Zone

  • Park, Seong Yong;Jung, Sung Ae;Lee, Sang Jo;Chung, Jae Woo
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.6
    • /
    • pp.641-651
    • /
    • 2019
  • The purpose of this study is to derive institutional improvement methods for promoting the Damaged Area Restoration Project in greenbelts. The current status of greenbelts in Gyeonggi-do, where greenbelts are extensively distributed was analyzed, and the relevant laws and regulations were reviewed to suggest measures to promote the restoration project. The area of damaged areas within greenbelts in Gyeonggi-do was 6,121,024 m2, accounting for about 0.52% of the total area of greenbelts, and more than 80% was found to be located in Namyangju (55.49%), Hanam (16.48%), and Siheung (8.68%). Various measures to improve the policy were examined as follows: reducing the minimum size of the restoration project area; adjusting baseline of recognizing range of damaged areas; introducing the right of claim for land sale; allowing long-term unexecuted urban parks to be replaced as alternative sites for parks and green spaces; simplifying administrative procedures; and allowing public participation. All of them are expected to promote the restoration project within greenbelts. In results, when the minimum size of area for the restoration project was reduced from 10,000 m2 into 5,000 m2, 3,000 m2 and 2,000 m2, the ratio of the number of combinable lots to the total number of lots increased from 4.4% to 18.8%, 38.8%, and 55.9% respectively in Namyangju. Morever, when the recognizable ranges of the restoration project were extended to the structures obtaining building permit as of March 30, 2016 and obtaining use approvals before December, 2017, the number of applicable lots increased by 5.1% and 9.2% respectively.

The Analysis of the Possibility for Using Converged Spatial Information(CSI) in National Territorial Planning - The Case Study of LH's Future Business about Land and Housing (융복합 공간정보의 국토계획 분야 활용가능성 분석 - LH 국토·주택관련 미래사업 예시를 중심으로)

  • Choi, Jun Young
    • Spatial Information Research
    • /
    • v.21 no.4
    • /
    • pp.71-81
    • /
    • 2013
  • Due to explosively increasing utilization in spatial information and a rapid development in geospatial technology related to national territorial and housing, there are increasing demands for converging spatial information on not only urban planning and real estate data but also newly generated data from smart phone, GPS to achieve comparative advantage of national territory. In this paper, we prospect the utilization of Converged Spatial Information(CSI) to future national territorial planning for the purpose of enhancing territorial competitiveness. For this purpose, considering the Korea Land and Housing corporation(LH) takes charge most of government's land and housing development projects, CSI usage of this company's 6 future business domains until 2029 were used as a case study. Also, 7 CSIs derived from literature review were surveyed to find the degree of CSI utilization in the national territorial future. In the analysis result, it was found that 3D data and mobile data among others have higher degree of utilization, and urban and regional development is the most highly utilizable domain for CSIs. After all, to revitalize the use of CSI in national territorial future, it is required to do a balanced construction of territorial use spatial information about marine use, coastal use, underground space besides land use.

Development of Working Platform for the Polymer Insulator String (송전선로 폴리머애자 공사용 장비 개발)

  • Min, Byeong-Wook;Wi, Shwa-Bok;Bang, Hang-Kwon;Choi, Han-Yeol;Baek, Soo-Gon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

Soil Pollution and Contaminated Soil Management of the Public Housing Agency in Residential Land Development (전국 토양오염실태 및 공공택지개발지구의 오염토양 관리)

  • Oh, Jeongik;Jin, Kyunam;Lee, Hyunjeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.377-386
    • /
    • 2016
  • The purposes of this research are to examine soil pollution in the nation and to explore the contaminated soil management of the public housing agency in public land for residential development. In so doing, the primary and secondary data were utilized, the former made use of the public data annually released by the Korea Ministry of Environment, and the latter relied on a self-administerd questionnaire survey conducted in the staff of the public housing agency, particularly those in charge of soil contamination in large-scale land, housing and urban development projects. The findings reveal that the national concentrations of 21 inorganic and organic soil contaminants (e.g., Cd, Cu, As, Hg, Pb, Cr, Zn, Ni, F, P, PCB, CN, Phenol, BTEX, TPH, TCE, PCE, Benzo(a)pyrene, and pH) in the land were extracted to be well below the risk level designated by the statutory guidance while industrial areas had them at a relatively modest level. In addition, the survey results indicate that the public housing agency didn't establish specific and clear guidelines for soil pollution and its remediation in the residential land development, so that contaminated sites have been primarily remediated by outsourcing companies. As the unexpected occurrence of contaminated sites causes the incurring expenses added to total project budget, the provision of both professional training and on-site manuals with the sufficient information on techniques and methods of soil contamination is critical to promptly and systematically deal with soil pollution.

An Enhanced Operating Scheme of Evaluation System for Construction Works -Focused on the KNHC System (시공평가제도의 효과적 운영방안 -대한주택공사 제도를 중심으로)

  • Choi Jin-Woo;Jung Sang-Bong;Park Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.279-284
    • /
    • 2001
  • The owner's evaluation system about the contractor's work performance is used to give the contractor some advantages or disadvantages. According to the result of evaluation of the contractor's performance in the given construction project, the owner identify the good contractors and give them some merits in the future project bidding. However, the system used in the Korean construction industry has caused many problems and has been operated improperly. As a case study, this paper investigates the current problems existed in the KNHC (Korean National Housing Corporation) evaluation system and suggests some directions for its efficient operation. In doing so, the study performed interviews with the KNHC officers and the related contractors, using a structured questionnaire

  • PDF

EFFICIENT SCREWING : last developments and Korean experience

  • Ines MEYUS;Maurice Bottiau;Myung-Whan Lee;Jong-Bae Park;Yong-Boo Park
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.405-414
    • /
    • 1999
  • The auger and screw piles have known an important evolution during the last decade. Besides the large success of augercast (CFA) piling systems, new systems have been developed combining, to a variable extent, the classical extraction auger with especially designed displacement tools in order to develop screw piles with partial or total lateral soil displacement. These last developments cover the whole range of lateral soil displacement and are more difficult than ever to compare. The authors present the latest evolutions in auger piling systems and compare them with respect to penetration performances, bearing capacities and amount of spoil generated. A special focus is given to a new efficient system: the OMEGA(H) pile in use in Korea since 1997. The results of the Hongcheon site are presented where this R system was applied for a new investment of the Korean National Housing Corporation (KNHC). This first important experience, with the execution of some 1,500 Omega piles with diameter 410 mm, is presented. The piles were installed through loose silty sands down to very dense sands and layers of gravel. The results of full-scale load tests are analysed and show the conformity with requirements of the clients.

  • PDF