• Title/Summary/Keyword: Kilovoltage

Search Result 42, Processing Time 0.022 seconds

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study

  • Shahmirzadi, Solaleh;Sharaf, Rana A.;Saadat, Sarang;Moore, William S.;Geha, Hassem;Tamimi, Dania;Kocasarac, Husniye Demirturk
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Purpose: The aim of this study was to assess artifacts generated in cone-beam computed tomography (CBCT) of 3 types of dental implants using 3 metal artifact reduction (MAR) algorithm conditions (pre-acquisition MAR, post-acquisition MAR, and no MAR), and 2 peak kilovoltage (kVp) settings. Materials and Methods: Titanium-zirconium, titanium, and zirconium alloy implants were placed in a dry mandible. CBCT images were acquired using 84 and 90 kVp and at normal resolution for all 3 MAR conditions. The images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the intensity of artifacts for each combination of material and settings. A 3-factor analysis of variance model with up to 3-way interactions was used to determine whether there was a statistically significant difference in the mean intensity of artifacts associated with each factor. Results: The analysis of all 3 MAR conditions showed that using no MAR resulted in substantially more severe artifacts than either of the 2 MAR algorithms for the 3 implant materials; however, there were no significant differences between pre- and post-acquisition MAR. The 90 kVp setting generated less intense artifacts on average than the 84 kVp setting. The titanium-zirconium alloy generated significantly less intense artifacts than zirconium. Titanium generated artifacts at an intermediate level relative to the other 2 implant materials, but was not statistically significantly different from either. Conclusion: This in vitro study suggests that artifacts can be minimized by using a titanium-zirconium alloy at the 90 kVp setting, with either MAR setting.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study

  • Larissa Pereira Lagos de Melo;Polyane Mazucatto Queiroz;Larissa Moreira-Souza;Mariana Rocha Nadaes;Gustavo Machado Santaella;Matheus Lima Oliveira;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.