• 제목/요약/키워드: KINEMATICS ANALYSIS

검색결과 633건 처리시간 0.024초

6-3 스튜워트 플랫폼 운동장치의 새로운 기구학 해석방법 (A New Kinematic Analysis of 6-3 Stewart Platform Manipulator)

  • 김낙인;이종원
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1206-1212
    • /
    • 2001
  • The kinematic analysis of Stewart platform manipulator(SPM) is carried out in order to reduce the calculation time for its forward kinematic solution when the iterative numerical method is employed. The kinematic equations for three substructures of the 6-3 SPM are newly derived by introducing Denavit-Hartenberg link parameters and using kinematic constraints associated with the SPM and substructure kinematics. It is shown that the forward kinematics can be easily solved from three nonlinear equations with three unknown variables only, leading to a great reduction in calculation time.

상대좌표를 이용한 복합연쇄 로봇기구의 역기구학 (Inverse Kinematics of Complex Chain Robotic Mechanism Using Ralative Coordinates)

  • 김창부;김효식
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3398-3407
    • /
    • 1996
  • In this paper, we derive an algorithm and develope a computer program which analyze rapidly and precisely the inverse kinematics of robotic mechanism with spatial complex chain structure based on the relative coordinates. We represent the inverse kinematic problem as an optimization problem with the kinematic constraint equations. The inverse kinematic analysis algorithm, therefore, consists of two algorithms, the main, an optimization algorithm finding the motion of independent joints from that of an end-effector and the sub, a forward kinematic analysis algorithm computing the motion of dependent joints. We accomplish simulations for the investigation upon the accuracy and efficiency of the algorithm.

Hyper Redundant Manipulator Using Compound Three-Bar Linkages

  • Koganezawa Koichi
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.320-327
    • /
    • 2005
  • A new mechanism for hyper redundant manipulator (HRM) is presented, which comprises of serially assembled compound three-bar linkages (CTL). The CTL mechanism has some unique properties. This paper presents the forward and inverse kinematics of this mechanism and shows the simulation of the HRM havig 9 CTL units. The recursive algorithm of the inverse kinematics that the author originally developed is employed. It is fast and stable ; moreover, it enables us to obtain a solution in which the end-point of the HRM is controlled by a portion of joints. It also presents the method of the dynamical analysis. There exist kinematical constraints in the proposed closed linkage mechanism. In the dynamic analysis constraints are sufficiently sustained by the constraint stabilization method that the author developed. The mechanical structure of the HRM having some CTL units that is under construction is shown.

비전문가를 위한 로봇 팔 역기구학의 해석 (Analysis of the Inverse Kinematics Method for Robot Arm Controlled by Amateur Users)

  • 이경문;이강희
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2014년도 제50차 하계학술대회논문집 22권2호
    • /
    • pp.259-260
    • /
    • 2014
  • IT 기술의 발달로 인해 로봇공학은 전문가의 영역에서 비전문가의 영역까지 두루 사용되고 있다. 그러나 현재 존재하는 소프트웨어는 여전히 높은 진입 장벽을 가지고 있다. 비전문가가 실질적으로 참고자료가 많이 부족하기 때문에 로봇 제어가 쉽지 않다. 본 논문에서는 5 자유도를 가진 로봇 팔을 움직이게 할 때 사용하는 기존의 역기구학(Inverse Kinematics)을 활용하여 기존 방법의 난도보다 직관적인 방법을 제시하여 비전문가들에게 로봇에 대한 높은 접근성을 제시한다.

  • PDF

A Study for analysis of Inverse Kinematics system to Character Animations & Motion Graphics education

  • Cho, Hyung-ik;Shin, Seung-Jung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.149-156
    • /
    • 2021
  • Today, 3D softwares have become an essential tool in all areas of Video, including Movies, Animations, CFs, Motion Graphics and Games. One of the most commonly used fields is the 3D character video part. However, these 3D character animations and motion graphics softwares are difficult to learn and too much to learn, making it difficult to learn them all in a university education with a limited time of four years. In this paper, many Inverse kinematics tools, which are essential in the 3D character animations and motion graphics field, compare and analyze the strengths and weaknesses of each tool, focusing on Bone, Character Studio, and Character Animation Toolkit, which are most commonly used in work fields. And use Delphi techniques for 3D experts to secure objectivity. Therefore, for universities that require large amounts of teaching in a limited time, I propose an analysis of which of the above three Inverse Kinetics tools is advantageous for students to select and focus on for efficient education.

수정된 병렬형매니퓰레이터의 성능해석에 관한 연구 (A Study on Performance analysis of a modified parallel manipulator)

  • 김주영;배재만;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.557-560
    • /
    • 2000
  • The Purpose of this study is analysis of kinematic for a modified manipulator and experimental test to certify auto-balancing operation. The test is carried out as follows. First, we solve the inverse kinematics and then do a closed loop control. Second we confirm translation displacement and rotation angle of a manipulator.

  • PDF

주속식 감속기의 운동학 및 치형해석 (Analysis of Kinematics and Tooth Profile in Harmonic Drive)

  • 전완주
    • Tribology and Lubricants
    • /
    • 제4권2호
    • /
    • pp.60-67
    • /
    • 1988
  • Conventional theory of gear mechanism can't be applied to analyze the harmonic drive due to specific movement of the teeth. This paper deals with an analysis of kinematics and geometry of the tooth engagement of a harmonic drive comprising circular spline, flexspline and wave generator. A theoretical new tooth profile of the flexspline in meshing internal rigid gear with involute profile is obtained. Characteristics of harmonic drive reducer are shown according to parameters such as deviation coefficient, deviation distance, addendum modification coefficient. As an example, the design of harmonic drive with 1:80 reduction ratio is presented.

기구학적 분석을 이용한 로봇 매니퓰레이터 개발 (Development of the Robot Manipulator for Kinematies)

  • 민병로;이대원
    • 생물환경조절학회지
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구는 오이수확기의 매니퓰레이터 개발을 위한 기구학적 분석을 하는 것이다. 매니퓰레이터의 정방향 기구학 및 역방향 기구학 분석을 한 후 실제 장치의 반복오차 측정실험을 통해 이론 값을 검증하였다. 매니퓰레이터는 총 세 개의 링크로서 한 개의 수직링크와 두 개의 호전링크로 구성되어져 있으며, 세 개의 스테핑 모터가 각 관절에 장착되어 링크에 동력을 전달한다. 주요 연구결과를 요약하면 다음과 같다. D-H Parameter를 이용하여 정방향 기구학에 의한 매리퓰레이터의 변환 연산자를 얻었다. 역방향 기구학의 해는 두가지로 나타났으며 삼각함수를 이용하여 해를 구하였다. 매리퓰레이터의 반복오차를 측정한 검증 실험에서는 X, Y, Z축에 대하여 반복 오차가 최대 2.60mm, 2.05mm, 1.55mm로 나타났으며, 정방향 및 역방향 기구학에서 오차의 최대지점 및 최소지점의 실제 좌표는 일치하였다. 반복오차 측정 결과는 매리퓰레이터의 목표지점인 오이의 직경에 비해 비교적 작게 나타났다. 측정오차는 실험중 발생한 실험오차로 판단된다. 매니퓰레이터의 오차를 줄이고 작업능률의 향상을 위해서는 링크의 수를 줄이고 오이의 품종 및 재배환경을 고려하여야 하며, 경량이면서도 견고한 재료를 사용하여 하중을 줄여야 한다.

Mass models of the Large Magellanic Cloud: HI gas kinematics

  • Kim, Shinna;Oh, Se-Heon;For, Bi-Qing;Sheen, Yun-Kyeong
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.60.3-61
    • /
    • 2020
  • We perform disk-halo decomposition of the Large Magellanic Cloud (LMC) using a novel HI velocity field extraction method, aimed at better deriving its HI kinematics and thus the dark matter density profile. For this, we use two newly developed galaxy kinematic analysis tools, BAYGAUD and 2DBAT which have been used for the kinematic analysis of resolved galaxies from Australian Square Kilometre Array (ASKAP) observations like WALLABY which is an all-sky HI galaxy survey in southern sky. By applying BAYGAUD to the combined HI data cube of the LMC taken with the Australia Telescope Compact Array (ATCA) and Parkes radio telescopes, we decompose all the line-of-sight velocity profiles into an optimal number of Gaussian components based on Bayesian MCMC techniques. From this, we disentangle turbulent non-circular gas motions from the overall rotation of the galaxy. We then derive the rotation curve of the LMC by applying 2DBAT to the separated circular motions. The rotation curve reflecting the total kinematics of the LMC, dark and baryonic matters is then be combined with the mass models of baryons, mainly stellar and gaseous components in order to examine the dark matter distribution. Here, we present the analysis of the extracted HI gas maps, rotation curve, and J, H and K-band surface photometry of the LMC.

  • PDF

Effects of Taping the Lower Back on the Lumbopelvic Region and Hip Joint Kinematics During Sit-to-Stand

  • Kim, Si-Hyun;Park, Kyue-Nam;Kwon, Oh-Yun;Choi, Houng-Sik
    • 한국전문물리치료학회지
    • /
    • 제21권4호
    • /
    • pp.49-55
    • /
    • 2014
  • Excessive lumbar flexion during sit-to-stand (STS) is a risk factor for lower back pain. Postural taping can prevent unwanted flexion of the lumbar spine. This study aimed to demonstrate the effect of taping the lower back on the lumbopelvic region and hip joint kinematics during STS. Sixteen healthy subjects participated. All subjects performed the STS with and without taping of the lower back. A three-dimensional motion analysis system was used to measure the kinematics of the lumbar spine, pelvis, and hip joint during STS. The angle of the peak lumbar flexion, pelvic anterior tilting, and hip flexion and angular displacement of the lumbar spine between starting position and maximal lumbar flexion were collected. Paired t-tests, or Wilcoxon's rank-sum test for non-parametric distribution, were used to assess differences in the measurements with and without taping. A p-value <.05 was taken to indicate a significant difference. Significant differences were observed in the angle of the peak lumbar flexion, pelvic anterior tilting, hip flexion and angular displacement of the lumbar spine (p<.05). Taping was associated with a significant decrease in the angle of peak lumbar flexion and angular displacement of the lumbar spine between the starting position and maximal lumbar spine flexion. In addition, the peak angle of pelvic anterior tilting and hip flexion were significantly increased with taping. The findings of this study suggest that taping the lower back can decrease excessive lumbar flexion, and increase the pelvic anterior tilting and hip flexion motion during STS.