• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.066 seconds

Stability Enhancement of Four-in-Wheel Motor-Driven Electric Vehicles Using an Electric Differential System

  • Hartani, Kada;Merah, Abdelkader;Draou, Azeddine
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1244-1255
    • /
    • 2015
  • This paper presents a new multi-machine robust control based on an electric differential system for electric vehicle (EV) applications which is composed of four in-wheel permanent magnet synchronous motors. It is based on a new master-slave direct torque control (DTC) algorithm, which is used for the control of bi-machine traction systems based on a speed model reference adaptive system observer. The use of an electric differential in the design of a new EV constitutes a technological breakthrough. A classical system with a multi-inverter and a multi-machine comprises a three-phase inverter for each machine to be controlled. Another approach consists of only one three-phase inverter for several permanent magnet synchronous machines. The control of multi-machine single-inverter systems is the subject of this study. Several methods have been proposed for the control of multi-machine single-inverter systems. In this study, a new master-slave based DTC strategy is developed to generate an electric differential system. The entire system is simulated by Matlab/Simulink. The simulation results show the effectiveness of the new multi-machine robust control based on an electric differential system for use in EV applications.

A Study on the Magnetically Suspended Spindle with 16-pole Radial Magnets (16 극의 반경방향 전자석을 갖는 자기부상 주축계 연구)

  • Park, Jong-Kweon;Ro, Seung-Kook;Kyung, Jin-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.2
    • /
    • pp.203-212
    • /
    • 2002
  • Active magnetic hearings allow much high surface speed than conventional ball bearings and therefore greatly suitable for high speed cutting. This paper describes a design and test of an active magnetic bearing system with 16-pole radial magnets. The spindle is originally designed for a CNC lathe and driven by outer motor with 5.5 kW power and maximum speed 10,000 rpm. Considering static load condition and geometric restrictions, radial magnet is designed 16-pole type for smaller outer diameter of the spindle system. Dynamic system characteristics such as natural frequency, critical speed, stiffness, damping and system stabilities are simulated with a rigid rotor model including direct feedback controller. The designed spindle system is realized with digital PIDD controller to compensate phase lag of PWM amplifier and magnet coils. With levitation and step response experiment the control system characteristics are tested, and the spindle is rotated up to 10,000 rpm stab1y.

Development of Uncertainty Evaluation Model for Vacuum Measurement Standards (진공측정표준의 불확도 평가모델 개발)

  • Hong, S.S.;Lim, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.313-321
    • /
    • 2011
  • The Korea Research Institute of Standards and Science (KRISS) has three major vacuum systems: an ultrasonic interferometer manometer (UIM), a static volume expansion system (SVES), and an orifice-type dynamic expansion system (ODES). For each system explict measurement model equations with multiple variables are respectively given. According to ISO standards, all these system variables errors were used to calculate the expanded uncertainty (U).

Microgrid Island Operation Based on Power Conditioning System with Distributed Energy Resources for Smart Grid (스마트 그리드를 위한 분산자원과 전력변환장치 기반 마이크로그리드 독립운전)

  • Heo, Sewan;Park, Wan-Ki;Lee, Ilwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.5
    • /
    • pp.1093-1101
    • /
    • 2017
  • Microgrid as a unit component consisting a smart grid is an isolated system, which has a decentralized power supply system. This paper proposes an electrical isolation of the microgrid from the utiliy grid based on a power conditioning system, and also proposes an operation method maintaining the isolated state efficiently using diverse distributed energy resources such as renewable energy sources and energy storage system. The proposed system minimizes the influence of the grid connection on the internal load though a phase detection and synchrnoization to the utiligy grid and the microgrid can be stable even if the grid is failed.

IEA ECBCS Annex 54 Economic Assessment Study of a Fuel Cell Integrated Ground Source Heat Pump Microgeneration System (연료전지 지열히트펌프 마이크로제너레이션 IEA ECBCS Annex 54 경제성 평가 연구)

  • Na, Sun-Ik;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.199-205
    • /
    • 2014
  • The integration of FC (Fuel Cell) and GSHP (Ground Source Heat Pump) hybrid system could produce a synergistic advantage in thermal and electric way. This study intends to analyse the economical aspect of a FC integrated GSHP hybrid system compared to the conventional system which is consisted with a boiler and a chiller. Based on the hourly simulation, the study indicated that GSHP system and FC+GSHP hybrid system could reduce the energy consumption on a building. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask C SPB(Simple Payback) method. The SPB was calculated using the economic balanced year of the alternative system over the conventional (reference) system. The SPB of the alternative systems (GSHP and FC+GSHP) with 50% initial incentive was 4.06 and 26.73 year respectively while the SPB without initial incentive of systems was 10.71 and 57.76 year.

Numerical Analysis on Freezing in the Ship Voyaging in Polar Regions

  • Kang, Ho-Keun;Kim, Ki-Pyoung;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.30-37
    • /
    • 2013
  • For vessels operating in the cold climate regions, the ballast water inside or hopper tanks above the waterline may be frozen, starting at the top of the tank and at the side walls. Therefore, countermeasures against freeze-up of the ballast tank such as air-bubbling system, hot steam injecting system, heating coil system and water circulating system are taken to prevent freeze-up phenomenon; however, there are no rigorous investigations of anti-freezing to examine the effectiveness and validity of systems against freeze-up of the ballast tank, in which the temperatures are about -$25^{\circ}C$ (ambient air temperature) and $0^{\circ}C$ (sea water), respectively. In this paper, to ensure reasonable specifications for cold regions if the measures from the above-mentioned systems against freeze-up are effective, the phenomenon of ballast tank freeze-up is simulated and discussed in low temperature conditions. With the results using the commercial CFD code, CFX 14, the most cost-effective solution is conducted to prevent being frozen along the outer surface.

Relation Research on Participation Valence and Learning Flow of Adult Learner in the Credit Bank System (성인학습자의 학점은행제 참여 유의가와 학습몰입 관계 연구)

  • SONG, Kyoung-Hwa;JUNG, Ju-Young;AHN, Young-Sik
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1209-1219
    • /
    • 2016
  • In knowledge based society, lifelong learning is increasing in order to meet educational needs of adult learners. Credit Bank system which is credited by individual experience, learning and qualifications are also emphasized for continuing learning participation. However, in spite of the importance of concern in the Credit Bank System, adult learners expectation and value are not high. The purpose of this study is to analyze participation valence and learning flow of adult learner in the Credit Bank System. The result of this study is summarized as follows: first, adult learners participated in the Credit Bank System to get new knowledge and skill based on internal and external motivation and requirement not involved with individual degree. Second, adult learners participating in the Credit Bank System are experiencing learning flow realizing that behavior of participation is compensated, adult learners are concentrating and feeling with satisfaction and pleasure to study. Third, participation in the Credit Bank System based on adult learner's own right learning requirement have been analyzed as it has a positive effect to the learning flow and have indicated that adult learners having high level of valence experience, recognition immersion, behavioral devotion, and egoistic immersion. Based on the conclusion, further studies are suggested.

Exergy Analysis and Optimization of Chiller System in Hydrogen Fueling Station Using R290 Refrigerant (R290 냉매를 이용한 수소 충전소 냉각시스템 엑서지 분석 및 공정 최적화)

  • HYEON, SOOBIN;CHOI, JUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.356-364
    • /
    • 2021
  • During the hydrogen fueling process, hydrogen temperature inside the compressed tank were limited below 85℃ due to the allowable pressure of tank material. The chiller system to cool compressed hydrogen used R407C, greenhouse gas with a high global warming potential (GWP), as a refrigerant. To reduce greehouse gas emission, it should be replaced by refrigerant with a low GWP. This study proposes a chiller system for fueling hydrogen with R290, consisted in propane, by applying the C3 pre-cooled system use d in the LNG liquefaction process. The proposed system consisted of hydrogen compression and cooling sections and optimized the operating pressure through exergy analysis. It was also compared to the exergy efficiency with the existing system at the optimal operating pressure. The result showed that the optimal operating pressure is 700 kPa in 2-stage, 840 kPa/490 kPa in 3-stage, and the exergy efficiency increased by 17%.

Development of Motor/Generator for 5kWh Superconductivity Flywheel Energy Storage System (5kWh급 초전도 플라이휠 에너지 저장장치용 전동발전기 개발)

  • Choi, T.S.;Kwon, H.N.;Song, J.H.;Koh, W.S.;Ryu, D.W.;Sung, T.H.;Han, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.24-26
    • /
    • 2003
  • 본 연구에서는 고효율, 반영구적인 수명 및 환경친화성으로 인해 효과적인 전력저장장치로 대두되고 있는 플라이휠 에너지 저장시스템 (FESS : Flywheel Energy Storage System)의 구동원으로 적용되는 전동발전기와 전력변환기에 대한 설계 및 제작을 수행하였다. 연구 대상 FESS의 저장용량은 5[kWh]이며 운전 속도는 30,000rpm이다. 전동발전기는 슬롯리플에 의한 와전류 손실이나 열손실을 고려하여 슬롯리스 Ring-wound형으로 선정하였으며, 전력변환기는 PWM Boost 컨버터를 통해 역률 및 DC 전압제어 그리고 Full Bridge 인버터를 통해 전동발전기 고속운전 제어를 실현할 수 있는 Topology를 채택하였다.

  • PDF

The Syntheses of charge transfer dyes and nanofiber formation for recognition and sensing (진단/감응용 전하 이동형 색소의 합성 및 나노 섬유의 제조)

  • Jung, Young-Sun;Park, Joon-Bae;Moon, Hee-Jung;Kim, Sung-Hoon;Bae, Jin-Seok
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.48-48
    • /
    • 2012
  • 화학센서는 분석물질과 감응물질간의 화학적 반응을 통해 분석물질을 선택적으로 인지하고 이를 통하여 특정물질을 실시간으로 분석할 수 있는 기술이다. 최근 화학센서로 색소를 이용하여 음이온을 진단/감응하는 기술이 각광 받고 있으며, 더불어 음이온을 선택적으로 인지함에 있어 검출하고자 하는 특정 음이온에 대한 민감도를 높이기 위한 노력이 계속되고 있다. 감응물질로 이용되는 색소는 주로 분자 내 전하 이동형 색소(intramolecular charge transfer dye)로 주위 환경 변화에 민감하게 반응하며, 자극에 따른 변화를 흡수와 발광, 굴절률의 변화 등으로 나타낸다. 또한 다양한 음이온 중 분석물질로써 연구 가치가 큰 음이온에는 플루오린화물(fluoride)이 있다. 이는 플루오린화물이 치아 보호와 골다공증에 중요한 역할을 하는 순기능을 가지는 반면 고농도 상태에서는 불소증(fluorosis)을 비롯한 악영향을 잠재적으로 가지기 때문에 그 양을 인지하는 것이 중요하게 여겨지기 때문이다. 따라서 본 연구에서는 2-(3,5,5-trimethylcyclohex-2-enylidene)-malononitirle과 indole-3-carboxaldehyde를 통하여 분자 내 전하 이동형 색소를 합성하고, $^1H$ NMR, GC-mas, EA로 합성된 색소의 물성을 분석하였다. 우선 반응물인 2-(3,5,5-trimethylcyclohex-2-enylidene)-malononitirle을 합성하기 위해 dimethylfor mamide(DMF) 용매 하에서 isophorone과 malononitrile을 12시간 반응시키고, 얻어진 결과물을 정제한다. 이후 indole-3-carboxaldehyde와 10시간 환류시켜 색소를 얻는다. 합성된 색소는 F 이온 검출에 이용되며, UV-vis 분광법을 이용하여 분석물질에 따른 흡수 정도와 강도 변화를 살펴본다. 연구의 최종적인 목적은 비단 진단/감응 색소의 합성이 아니라 나노 섬유 소재와 색소의 접합을 통해 진단/감응형 나노 섬유를 개발하는 것으로 이를 위해 전기방사법이 이용된다.

  • PDF