• Title/Summary/Keyword: K-file

Search Result 1,990, Processing Time 0.026 seconds

Building a Database of DQT Information to Identify a Source of the SmartPhone JPEG Image File (스마트폰 JPEG 파일의 출처 식별을 위한 DQT 정보 데이터베이스 구축)

  • Kim, MinSik;Jung, Doowon;Lee, Sang-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.359-367
    • /
    • 2016
  • As taking pictures by using smartphones has become more common in society, there are many incidents which are unexpected manipulation of images and leak of confidential information. Because of those incidents, demands that identify forgery/alteration of image file and proves of the original copy is constantly increasing. In general, smartphone saves image file as JPEG form and it has DQT which determines a compression rate of image in a header part of image. There is also DQT in Thumbnail image which inside of JPEG. In previous research, it identified a smartphone which take image by only using DQT, However, the research has low accuracy to identify the devices. There are two main purposes in this research. First, this research will analogize a smartphone and an application that takes a picture, edits and save an image file by testing not only about a DQT information but also a information of Thumbnail image. Second, the research will build a database of DQT and Thumbnail information in JPEG file to find more accurate image file's origin.

Program Execution Speed Improvement using Executable Compression Method on Embedded Systems (임베디드 시스템에서 실행 가능 압축 기법을 이용한 프로그램 초기 실행 속도 향상)

  • Jeon, Chang-Kyu;Lew, Kyeung-Seek;Kim, Yong-Deak
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The performance improvement of the secondary storage is very slow compared to the main memory and processor. The data is loaded from secondary storage to memory for the execution of an application. At this time, there is a bottleneck. In this paper, we propose an Executable Compression Method to speed up the initial loading time of application. and we examined the performance. So we implemented the two applications. The one is a compressor for Execution Binary File. and The other is a decoder of Executable Compressed application file on the Embedded System. Using the test binary files, we performed the speed test in the six files. At the result, one result showed that the performance was decreased. but others had a increased performance. the average increasing rate was almost 29% at the initial loading time. The level of compression had different characteristics of the file. And the performance level was dependent on the file compressed size and uncompress time. so the optimized compression algorithm will be needed to apply the execution binary file.

The Efficiency of the Ni-Ti Rotary Files in Curved Simulated Canals Shaped by Novice Operators (만곡모형근관에서 초심자가 근관형성시 Ni-Ti 전동파일의 효용성)

  • Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.146-155
    • /
    • 2003
  • 여러 가지 장점으로 인해 Ni-Ti 전동 파일을 근관성형에 사용하는 빈도가 점차 증가되는 추세이지만, 초심자를 대상으로 한 연구는 부족한 실정이다. 이에 본 연구에서는 초심자에서 Ni-Ti 전동 파일을 사용할 때 근관 형성의 효용성을 평가하고, 어떤 방법이 초심자에게 적절한지를 알아보고자 하였다. 근관형태가 재현된 레진 블록을 이용하여 12명의 초심자와 4명의 숙련자가 근관 형성을 시행하였다. 각 술자는 ProFile, ProTaper, Hybrid (ProFile+ProTaper)를 이용하여 각각의 레진 블록을 세 개씩 근관형성하고, 각 파일 별의 근관 형성 시간을 기록하였다. 근관 형성 전과 후의 digital 이미지를 중첩하여 치근단으로부터 1, 2, 3, 4, 5, 6, 7mm level에서 근관단면의 총길이 변화량, 만곡 외측의 길이 변화량, 만곡 내측의 길이 변화량, 중심이동량, 중심이동율과 치근단에서의 apical transportation을 구하고, 초심자와 숙련자 사이의 차이를 비교 평가하였다. 실험결과 ProFile군의 1, 3, 5, 6, 7mm level과 ProTaper군의 6mm level, Hybrid군의 3mm level에서 초심자의 근관단면의 총길이 변화량이 숙련자보다 많았다. 모든 군에서 치근단으로부터 4, 5, 6, 7mm level에서는 근관 중심이 만곡내측으로 이동하였고, 1 2, 3mm level 에서는 만곡외측으로 이동하였으나, 숙련자가 시행한 Hybrid군의 3mm level과 비숙련자가 시행한 ProTaper 군의 3mm level에서는 만곡내측으로 이동하였다. 모든 군의 3mm level과 ProFile 군의 5mm level에서 초심자의 중심이동율이 숙련자에 비해 컸으며, 초심자가 ProTaper를 사용시 더 큰 apical trans portation을 보였고, 모든 군에서 초심자가 근관형성시 더 많은 시간이 걸렸다. ProFile과 ProTaper를 이용한 Hybrid technique이 초심자에게 추천되며, 초심자들도 충분히 교육받는다면 만곡된 근관의 근관형성에 있어서 Ni-Ti rotary file의 이용이 가능하리라고 사료된다.

A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION (기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구)

  • Kim, Byung-Hyun;Lee, Young-Kyoo;Kim, Young-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

A Measurement Study of User Behavior and File Pollution in DHT-based P2P Networks (DHT 기반의 P2P 네트워크에서 사용자 행동양식 및 파일 오염에 관한 측정 연구)

  • Shin, Kyu-Yong;Yoo, Jin-Cheol;Lee, Jong-Deog
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.3
    • /
    • pp.131-140
    • /
    • 2011
  • File pollution (i.e., sharing of corrupted files, or contaminating index information with bogus index records) is a de facto problem in many file sharing Peer-to-Peer (P2P) systems in use today. Since pollution squanders network resources and frustrates users with unprofitable downloads (due to corrupted files) and unproductive download trials (due to bogus index records), the viability of P2P systems (and similar distributed information-sharing applications) is questionable unless properly addressed. Thus, developing effective anti-pollution mechanisms is an immediate problem in this literature. This paper provides useful information and deep insight with future researchers who want to design an effective anti-pollution mechanism throughout an extensive measurement study of user behavior and file pollution in a representative DHT-based P2P system, the Kad network.

A Study of Method to Restore Deduplicated Files in Windows Server 2012 (윈도우 서버 2012에서 데이터 중복 제거 기능이 적용된 파일의 복원 방법에 관한 연구)

  • Son, Gwancheol;Han, Jaehyeok;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1373-1383
    • /
    • 2017
  • Deduplication is a function to effectively manage data and improve the efficiency of storage space. When the deduplication is applied to the system, it makes it possible to efficiently use the storage space by dividing the stored file into chunks and storing only unique chunk. However, the commercial digital forensic tool do not support the file system analysis, and the original file extracted by the tool can not be executed or opened. Therefore, in this paper, we analyze the process of generating chunks of data for a Windows Server 2012 system that can apply deduplication, and the structure of the resulting file(Chunk Storage). We also analyzed the case where chunks that are not covered in the previous study are compressed. Based on these results, we propose the method to collect deduplicated data and reconstruct the original file for digital forensic investigation.

A COMPARATIVE STUDY OF THE EFFECT K - FILE AND ULTRASONIC INSTRUMENT IN CLEANING AND SHAPING ROOT CANAL (K-File과 초음파기구의 근관확대 및 세척효과에 대한 비교연구)

  • Kim, Sang-Seop;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.413-420
    • /
    • 1992
  • The purpose of this study was to compare the effectiveness of hand instrumentation with K - file and ultrasonic instrumentation and irrigation system in removing pulpal debris and canal wall planing. 20 mandibular molar teeth were instrumented to size 30 K - file and 20 teeth were instrumented with ultrasonic Suprasson. And Normal Saline and 2.5% NaOCl were used as irrigation solution. All specimens were viewed at the coronal, middle, and apical third of the root canals for the evaluation of the cleaning effect under the multiview microscope. The result were as follows : 1. All of the technique and irrigation solution was effecient in the debris removal and canal wall planing at the cervical and middle thirds of the root canal. 2. All of the techniques and irrigation solutions was less efficient in the debris removal and canal planing at the apical third of the root canal. 3. The debris removal and canal wall planing was depended more on the anatomical variations of the root canal than on the techniques and irrigation solutions.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE REMOVING EFFICIENCY OF SMEAR LAYER BY K-FILE AND ULTRASONIC INSTRUMENT (K-FILE과 초음파 기구의 도말층제거효과에 대한 주사전자 현미경적 연구)

  • Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.97-105
    • /
    • 1994
  • The purpose of this study was to evaluate the smear layer removing efficiency of two root canal preparation techniques. Twelve single-rooted teeth were used in two groups of six each. Group 1 was biomechanically prepared by hand using a K-file with a high volume of normal saline irrigation. Group 2 was. prepared by using ultrasonically activated K-file with a constant high volume of normal saline irrigation. After the experimental procedures, each root was split saggitally. The removing efficiency of the preparation methods were assessed in terms of surface condition of the canal walls at three levels, those coronal, middle, and apical thirds. On the basis of remaining debris, presence of smear layer, and patency of dentinal tubules, each canal was evaluated according to a scale form 0 to 2. A statistical analysis was used to indicated any significant differences in surface condition between the two methods. There was no statistical significance between hand instrumentation and ultrasonic instrumentation at the cervical third but removing efficiency of ultrasonic instrumentation was superior. No statistically significant differences were obhserved for middle or apical third.

  • PDF

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.