• Title/Summary/Keyword: K ion detection

Search Result 477, Processing Time 0.025 seconds

Distribution of Ion Channels in Trigeminal Ganglion Neurons of Rat.

  • Kim, A.K.;Choi, K.K.;Choi, H.Y.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.581.1-581
    • /
    • 2001
  • Trigeminal nerve functions movement and sensation on orofacial region. Therefore, it is very important in dental clinic. Neurons with their cell bodies in trigeminal ganglion of trigeminal nerve root are primary sensory neurons and playa role of tactile sense, pressure, vibration and pain of orofacial area. Transmission of these senses depends on ion channels, we know that trigeminal ganglion neuron exists many kind of ion channels. Methods of definition on ion channel are several, but in this study we use immunostaining for detection of ion channels.(omitted)

  • PDF

Development of Ion-Selective Electrodes for Agriculture

  • Yang-Rae Kim
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.153-153
    • /
    • 2022
  • There is a growing need to develop ion sensors for agriculture. As a result, several technologies have been developed, such as colorimetry, spectrophotometry, and ion-selective electrode (ISE). Among them, ISE has some advantages compared to others. First, it does not require pre-treatment processes and expensive equipment. Second, it is possible for the portable detection system by introducing small-sized electrodes. Finally, real-time and multiple detections of several ions are pursued. It is well-known that N, P, and K nutrients are critical for crop growth. With the development of agriculture techniques, the importance of soil nutrient analysis has attracted much attention for cost-effective and eco-friendly agriculture. Among several issues, minimizing the use of fertilizers is significant through quantitative analysis of soil nutrients. As a result, it is highly important to analyze certain nutrients, such as N (ammonium ion, nitrate ion, nitrite ion), P (dihydrogen phosphate ion, monohydrogen phosphate ion), and K (potassium ion). Therefore, developing sensors for accurate analysis of soil nutrients is highly desired. n this study, several ISEs have been fabricated to detect N, P, and K. Their performance has been intensively studied, such as sensitivity, selectivity coefficient, and concentration range, and compared with commercialized ISEs. In addition, preliminary tests on the in-situ N, P, and K monitoring have been conducted inside the soil.

  • PDF

Molecular Level Detection of Heavy Metal Ions Using Atomic Force Microscope (원자간인력현미경을 이용한 분자수준의 중금속 이온 검출)

  • Kim, Younghun;Kang, Sung Koo;Choi, Inhee;Lee, Jeongjin;Yi, Jongheop
    • Clean Technology
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • A metal ion detector with a submicron size electrode was fabricated by field-induced AFM oxidation. The square frame of the mesa pattern was functionalized by APTES for the metal ion detection, and the remaining portion was used as an electrode by the self-assembly of MPTMS for Au metal deposition. The conductance changed with the quantity of adsorbed copper ions, due to electron tunneling between the mobile and surface electrodes. The smaller electrode has a lower limit of detection due to the enhancement in electron tunneling through metal ions that are adsorbed between the conductive-tip (mobile) and the surface (fixed) electrode. This two-electrode system immobilized with different functional groups was successfully used in the selective adsorption and detection of target materials.

  • PDF

Determination of Trace Iodide in Sodium Bisulfite Aqueous Solution by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 Sodium bisulfite 수용액 중의 미량 요오드 정량)

  • Park, Yang-Soon;Kim, Do-Yang;Choi, Kwang-Soon;Park, Soon-Dal;Han, Sun-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.304-308
    • /
    • 2000
  • The iodide was recovered from a simulated spent fuel to the sodium bisulfite aqueous solution. It was discussed that the trace iodide (below 1 ppm) was determined without the matrix effect of 0.1 M sodium bisulfite and 1 mM $HNO_3$ in aqueous solution by ion chromatography with UV detection. AS4A-SC (DIONEX) column and UV-absorption spectrophotometer were used. The UV-absorption spectra of sodium bisulfite, nitric acid and iodide were obtained, and then 230 nm was selected as an absorption wavelength for iodide determination. 0.1 M NaCl eluent was optimum condition. In this condition the calibration curve of iodide was obtained on the range of about 0-1,000 ppb. The linear coefficient was 0.99993 and the detection limit was 5 ppb. The relative standard deviation was 1.26%.

  • PDF

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.

Simultaneous Determination of Anions and Cations in Natural Water by Ion-exclusion/Cation-exchange Chromatography with a Weakly Acidic Cation-exchange Resin Column

  • Lee, Kwang-Pill;Choi, Seong-Ho;Park, Yu-Chul;Bae, Zun-Ung;Lee, Mu-Sang;Lee, Sang-Hak;Chang, Hye-Yong;Kwon, Se-Mok;Kazuhiko Tanaka
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1324-1328
    • /
    • 2003
  • The simultaneous determination of anions ($SO_4 ^{2-},\;Cl^-,\;and\;NO_3^-$) and cations ($Na^+,\;NH^{4+},\;K^+,\;Mg^{2+},\;and\;Ca^{2+}$) in natural water obtained by Nakdong River waters system in Korea were performed by ion-exclusion/cationexchange chromatography with conductimetric detection. The stationary phase was a polymethacrylate-based weakly acidic cation-exchange resin column in the $H^+$-form and a weak-acid eluent. When using only a 1.4 mM sulfosalicylic acid/6 mM 18-crown-6 ether as an eluent, good resolution of both anions and cations, minimum time required for the separation, and satisfactory detection sensitivity were obtained in a reasonable time. The method was successfully applied to the simultaneous determination of anions and cations in natural waters.

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

Determination of Cyanide Ion in the Presence of Sulfide Ion by Differential Pulse Cathodic Stripping Voltammetry (시차펄스 음극벗김 전압전류법에 의한 황화이온의 존재하에서 시안화이온의 정량)

  • Park, Se Yeon;Kwon, Young Soon
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.47-55
    • /
    • 1993
  • The quantitative determination of trace cyanide ion in the presence of sulfide ion has been studied by addition of cupric ion using differential pulse Cathodic Stripping Voltammetry. The detection limit of cyanide ion in the presence of $5.0*10^{-5}M$ sulfide ion and $1.0*10^{-3}M$ cupric ion was $2.0*10^{-7}M$ in KCI-Phosphate buffer(pH=7.0) at accumulation potential -0.30V and accumulation time 3.0 min.

  • PDF

Acrylic Polymer Composition Suitable for Ion Delivery and Selective Detection of Proton, and Hydroxyl and Cu(II) Ions (이온 이동에 적합한 아크릴고분자 박막의 조성과 수소이온, 수산화이온, 구리이온의 선택적 검출)

  • Lee, Dahye;Woo, Heejung;Do, Jung Yun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.801-808
    • /
    • 2014
  • Ion diffusion and chemical binding to acrylic polymer were investigated in a solid film. The composition of acrylic monomers containing amino group and carboxylic acid was adjusted for rapid ion migration in the film. p-Methylred (PMR) and phenolphthalein derivatives were optically sensitive to the concentration of proton and hydroxyl anion, respectively and verified the ion migration through the film layers. A rapid proton migration was observed in the film of a high amino content. On the other hand, $OH^-$ migration occurred rapidly in a high content of carboxylic acid group. The proton migration occurred through the internal layer as well as surface layer of a film and was reversible during 50 repetition examination. Copper(II) ion migration was examined with a Rhodamine-containing polymer film. The light absorption and emission spectra of a Rhodamine-Cu complex showed the key contribution of carboxylic acid group to the Cu(II) migration in a film.

Ion chromatographic determination of chlorite and chlorate in chlorinated food using a hydroxide eluent

  • Kim, Dasom;Jung, Sungjin;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, Hekap
    • Analytical Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.57-67
    • /
    • 2017
  • This study was conducted to develop an analytical technique for determination of chlorite and chlorate concentrations in fresh-cut food and dried fish products by an ion chromatography/conductivity detection method using a hydroxide mobile phase. Deionized water was added to homogenized samples, which were then extracted by ultrasound extraction and centrifuged at high speed (8,500 rpm). Subsequently, a Sep-Pak tC18 cartridge was used to purify the supernatant. Chlorite and chlorate ions were separated using 20 mM KOH solution as the mobile phase and Dionex IonPac AS27 column as the stationary phase. Ethylenediamine was used as sample preservative and dibromoacetate was added to adjust for the disparity in extraction efficiencies between the food samples. The method detection limit) for chlorite and chlorate were estimated to be 0.2 mg/kg and 0.1 mg/kg, respectively, and the coefficient of determination ($r^2$) that denotes the linearity of their calibration curves were correspondingly measured to be 0.9973 and 0.9987. The recovery rate for each ion was 92.1 % and 96.3 %, with relative standard deviations of 7.47 % and 6.18 %, respectively. Although neither chlorite nor chlorate was detected in the food samples, the analytical technique developed in this study may potentially be used in the analysis of disinfected food products.