• Title/Summary/Keyword: K Bank

Search Result 2,691, Processing Time 0.034 seconds

Identity of Spirometra theileri from a Leopard (Panthera pardus) and Spotted Hyena (Crocuta crocuta) in Tanzania

  • Eom, Keeseon S.;Park, Hansol;Lee, Dongmin;Choe, Seongjun;Kang, Yeseul;Bia, Mohammed Mebarek;Ndosi, Barakaeli Abdieli;Nath, Tilak Chandra;Eamudomkarn, Chatanun;Keyyu, Julius;Fyumagwa, Robert;Mduma, Simon;Jeon, Hyeong-Kyu
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.6
    • /
    • pp.639-645
    • /
    • 2019
  • In the present study, a Spirometra species of Tanzania origin obtained from an African leopard (Panthera pardus) and spotted hyena (Crocuta crocuta) was identified based on molecular analysis of cytochrome c oxidase I (cox1) and NADH dehydrogenase subunit I (nad1) as well as by morphological observations of an adult tapeworm. One strobila and several segments of a Spirometra species were obtained from the intestine of an African male leopard (Panthera pardus) and spotted hyena (Crocuta crocuta) in the Maswa Game Reserve of Tanzania. The morphological characteristics of S. theileri observed comprised 3 uterine loops on one side and 4 on the other side of the mid-line, a uterine pore situated posterior to the vagina and alternating irregularly either to the right or left of the latter, and vesicular seminis that were much smaller than other Spirometra species. Sequence differences in the cox1 and nad1 genes between S. theileri (Tanzania origin) and S. erinaceieuropaei were 10.1% (cox1) and 12.0% (nad1), while those of S. decipiens and S. ranarum were 9.6%, 9.8% (cox1) and 13.0%, 12.6% (nad1), respectively. The morphological features of the Tanzania-origin Spirometra specimens coincided with those of S. theileri, and the molecular data was also consistent with that of S. theileri, thereby demonstrating the distribution of S. theileri in Tanzania. This places the leopard (Panthera pardus) and spotted hyena (Crocuta crocuta) as new definitive hosts of this spirometrid tapeworm.

Reference Trajectory Analysis and Trajectory Control by Bank Angle for Re-Entry Vehicle

  • Cho, Kyeum-Rae;Lee, Dae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.745-756
    • /
    • 2002
  • The re-entry problem consists of guidance design and trajectory control. This paper summarizes the detailed relationships between the velocity, drag acceleration and altitude in determining reference trajectories. The computational issues are also addressed, and the performance of the proposed simple nonlinear control of a bank angle for the longitudinal/ lateral trajectory is demonstrated. In particular, the fixed bank angle methods that can reduce the drag acceleration errors at low-speeds are proposed. The importance of bank reversals with respect to the azimuth errors Is also elucidated.

A Case Study on the Farm Revival Program Conducted by Farmland Bank in Gangwon Province (경영회생지원 농지매입사업 이용실태에 관한 사례연구: 강원지역 농가를 중심으로)

  • Yi, Hyangmi;Kim, Mi Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.3
    • /
    • pp.201-212
    • /
    • 2014
  • The Farm Revival Program of the Farm Land Bank, implemented in 2006, initiated as the Agricultural Land Bank's business proposal to achieve efficient usage of farm land. Also, expansion of Farm Revival Program will bring positive effects when considering the fact that Farm Revival Program contributes to farm liability issues and management improvements. However, despite the importance of Farm Revival Program, searching for improvement methods through a rural demand survey is very insufficient. The following research limits the target to farms that applied for the management redemption project within Gangwon Province and examined the application motivation, project satisfaction, and demands of the farms. This research holds value as a fundamental data which reflects the demands of farms to better manage Farm Land Purchasing of the Farm Land Bank.

Morphology control of inkjet-printed small-molecule organic thin-film transistors with bank structures

  • Kim, Yong-Hoon;Park, Sung-Kyu
    • Journal of Information Display
    • /
    • v.12 no.4
    • /
    • pp.199-203
    • /
    • 2011
  • Reported herein is the film morphology control of inkjet-printed 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-pentacene) organic thin-film transistors for the improvement of their performance and of the device-to-device uniformity. The morphology of the inkjetted TIPS-pentacene films was significantly influenced by the bank geometry such as the bank shapes and confinement area for the channel region. A specific confinement size led to the formation of uniform TIPS-pentacene channel layers and better electrical properties, which suggests that the ink volume and the solid concentration of the organic-semiconductor solutions should be considered in designing the bank geometry.

Bank's Market Power and Firm Access to Capital Markets in Asia

  • Lee, Sunglyong;Seol, Youn
    • Management Science and Financial Engineering
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • We investigate the effect of bank's market power on financing constraints of non-financial firms in 11 Asian countries between 1995 and 2009. Using firm-level data we analyze financial constraints with the Euler equation derived from the dynamic investment model. We find that with a highly concentrated banking sector firms which have high market power are less financially constrained. These results are consistent with an information-based hypothesis that more market power increases bank's advantage to produce information on potential borrowers.

Potential of River Bottom and Bank Erosion for River Restoration after Dam Slit in the Mountain Stream

  • Kang, Ji-Hyun;So, Kazama
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.46-46
    • /
    • 2011
  • Severe sediment erosion during floods occur disaster and economic losses, but general sediment erosion is basic mechanism to move sediment from upstream to downstream river. In addition, it is important process to change river form. Check dam, which is constructed in mountain stream, play a vital role such as control of sudden debris flow, but it has negative aspects to river ecosystem. Now a day, check dam of open type is an alternative plan to recover river biological diversity and ecosystem through sediment transport while maintaining the function of disaster control. The purpose of this paper is to verify sediment erosion progress of river bottom and bank as first step for river restoration after dam slit by cross-sectional shear stress and critical shear stress. Study area is upstream reach of slit check dam in mountain stream, named Wasada, in Japan. The check dam was slit with two passages in August, 2010. The transects were surveyed for four upstream cross-sections, 7.4 m, 34 m, 86 m, and 150 m distance from dam in October 2010. Sediment size was surveyed at river bottom and bank. Sediment of cobble size was found at the wetted bottom, and small size particles of sand to medium gravel composed river bank. Discharge was $2.5\;m^3/s$ and bottom slope was 0.027 m/m. Excess shear stress (${\tau}_{ex}$) was calculated for hydraulic erosion by subtracting the values of critical shear stress (${\tau}_{c}$) from the value of shear stress (${\tau}$) at river bottom and bank (${\tau}_{ex}=\tau-{\tau}_c$). Shear stress of river bottom (${\tau}_{bottom}$) was calculated using the cross-sectional shear stress, and bank shear stress (${\tau}_{bank}$) was calculated from the method of Flintham and Carling (1988). $${\tau}_{bank}={\tau}^*SF_{bank}((B+P_{bed})/(2^*P_{bank}))$$ where $SF_{bank}=1.77(P_{bed}/p_{bank}+1.5)^{-1.4}$, B is the water surface width, $P_{bed}$ and $P_{bank}$ are wetted parameter of the bed and bank. Estimated values for ${\tau}_{bottom}$ for a flow of $2.5\;m^3/s$ were lower as 25.0 (7.5 m cross-section), 25.7 (34 m), 21.3 (86 m) and 19.8 (150 m), in N/$m^2$, than critical shear stress (${\tau}_c=62.1\;N/m^2$) with cobble of 64 mm. The values were insufficient to erode cobble sediment. In contrast, even if the values of ${\tau}_{bank}$ were lower than the values for ${\tau}_{bottom}$ as 18.7 (7.5 m), 19.3 (34 m), 16.1 (86 m) and 14.7 (150 m), in N/$m^2$, excess shear stresses were calculated at the three cross-sections of 7.5 m, 34 m, and 86 m distances compare with ${\tau}_c$ is 15.5 N/$m^2$ of 16mm gravel. Bank shear stresses were sufficient for erosion of the medium gravel to sand. Therefore there is potential to erode lateral bank than downward erosion in a flow of $2.5\;m^3/s$. Undercutting of the wetted bank can causes bank scour or collapse, therefore this channel has potential to become wider at the same time. This research is about a potential of sediment erosion, and the result could not verify with real data. Therefore it need next step for verification. In addition an erosion mechanism for river restoration is not simple because discharge distribution is variable by snow-melting or rainy season, and a function for disaster control will recover by big precipitation event. Therefore it needs to consider the relationship between continuous discharge change and sediment erosion.

  • PDF

Analysis of a breakdown in 154 kV STATCON Bank condenser cell (154kV SC Bank 콘덴서 절연파괴 대책연구)

  • Ju H.J.;Khak J.S.;Woo J.W.;Kang Y.W.;shim E.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.537-540
    • /
    • 2004
  • 154 kV 변전소에 설치 운전 중인 SC Bank콘덴서 셀의 절연파괴 고장이 빈번하게 발생되어 전력계통의 운용 덴 변전소 운전에 지장을 주는 사례가 많이 발생하였다. 따라서 이의 고장원인 진단을 통하여 대책수립을 하고자 EMTP(Electro-Magnetic Transient Program)를 이용하여 50의 SC Bank의 정상상태시 과전압, 과전류에 의한 소손현상을 검토하고, 계통조건에 따른 공진점변화와 고조파에 따른 이상전압 및 콘덴서 셀 전압의 상승 현상을 검토 분석하고, 현장 실측을 통하여 고조파성분에 따른 과전압 및 과전류를 분석하여 대책을 제시한 사례 연구의 결과이다.

  • PDF

A study on the planning for construction and expanding of distribution substation considering contingency (상정사고를 고려한 배전용 변전소 신,증설 계획 수립에 관한 연구)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Han, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.552-554
    • /
    • 2000
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of bank system. In this paper, at first, proper sphere of supply area in each district which could be standardized with respect to its supply capacity is established under assumption which was made long term load forecasting in district respectively. Secondly, goal of utilization ratio according to configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents Finally, optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio could be anticipated.

  • PDF