• 제목/요약/키워드: K&C test

검색결과 10,688건 처리시간 0.04초

일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석 (Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System)

  • 이준구;손광영;박희석;박희윤;구인수
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF

NoC-Based SoC Test Scheduling Using Ant Colony Optimization

  • Ahn, Jin-Ho;Kang, Sung-Ho
    • ETRI Journal
    • /
    • 제30권1호
    • /
    • pp.129-140
    • /
    • 2008
  • In this paper, we propose a novel ant colony optimization (ACO)-based test scheduling method for testing network-on-chip (NoC)-based systems-on-chip (SoCs), on the assumption that the test platform, including specific methods and configurations such as test packet routing, generation, and absorption, is installed. The ACO metaheuristic model, inspired by the ant's foraging behavior, can autonomously find better results by exploring more solution space. The proposed method efficiently combines the rectangle packing method with ACO and improves the scheduling results by dynamically choosing the test-access-mechanism widths for cores and changing the testing orders. The power dissipation and variable test clock mode are also considered. Experimental results using ITC'02 benchmark circuits show that the proposed algorithm can efficiently reduce overall test time. Moreover, the computation time of the algorithm is less than a few seconds in most cases.

  • PDF

IEEE 1149.7 표준 테스트 인터페이스를 사용한 핀 수 절감 테스트 기술 (Reduced Pin Count Test Techniques using IEEE Std. 1149.7)

  • 임명훈;김두영;문창민;박성주
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.60-67
    • /
    • 2013
  • 다양한 Intellectual Property(IP)로 이루어진 복잡한 SoC 테스트에 있어 테스트 비용 절감은 필수적이다. 본 논문에서는 IEEE Std. 1500과 IEEE Std. 1149.7 인터페이스를 사용하여 적은 수의 핀 수로 IP 기반의 System-on-a-Chip(SoC) 테스트를 가능케 하는 테스트 구조를 제안한다. IEEE Std. 1500은 IP 기반의 SoC 테스트에 있어 각 IP를 테스트할 수 있는 독립된 접근 경로를 제공한다. 본 논문에서는 이러한 독립된 테스트 경로를 IEEE Std. 1149.7로 제어 가능하도록 구성함으로서 SoC의 테스트 핀 수를 2 핀으로 줄일 수 있게 한다. 본 기술은 Wafer 및 Package 수준 테스트에 요구되는 테스트 핀 수를 줄임으로서 동시에 테스트 가능한 대상회로의 수를 늘릴 수 있고, 결과적으로 전체적인 양산 테스트 비용을 크게 절감할 수 있게 한다.

열충격 시험 후 태양전지 파괴 모드에 따른 전기적 특성변화 (Electric Degradation of Failure Mode of Solar Cell by Thermal Shock Test)

  • 강민수;전유재;신영의
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.327-332
    • /
    • 2013
  • 일본 연구에서는 열충격 시험을 통한 태양전지의 파괴모드에 따른 전기적 특성을 분석하였다. 시편은 Photovoltaic Module을 만들기 전 3 line Ribbon을 Tabbing한 단결정 Solar Cell을 제작하였다. 열충격 시험 Test 1의 온도조건은 저온 $-40^{\circ}C$, 고온 $85^{\circ}C$, Test 2는 저온 $-40^{\circ}C$, 고온 $120^{\circ}C$에서 Ramping Time을 포함하여 각각 15분씩, 총 30분을 1사이클로 500사이클을 각각의 조건으로 수행하였다. 열충격 시험 후 Test 1에서는 4.0%의 효율 감소율과 1.5%의 Fill Factor 감소율을 확인하였으며, Test 2에서는 24.5%의 효율 감소율과 11.8%의 Fill Factor 감소율을 확인하였다. EL(Electroluminescence)촬영 및 단면을 분석한 결과, Test 1과 Test 2 시편 모두 Cell 표면 및 내부에서의 Crack이 발견되었다. 하지만, Test 2의 시험이 Test 1보다 가혹한 온도조건의 시험으로 인해 Test 1에서 나타나지 않았던, Cell 파괴를 Test 2에서 확인하였다. 결국, Test 1에서 효율의 직접적인 감소 원인은 Cell 내부에서의 Crack이며, Test 2에서는 Cell 내부에서의 Crack 및 Cell 파괴로 인한 Cell 자체의 성능저하로 효율이 크게 감소한다는 것을 본 실험을 통하여 규명하였다.

Effect of Codonopsis lanceolata with Steamed and Fermented Process on Scopolamine-Induced Memory Impairment in Mice

  • Weon, Jin Bae;Yun, Bo-Ra;Lee, Jiwoo;Eom, Min Rye;Ko, Hyun-Jeong;Kim, Ji Seon;Lee, Hyeon Yong;Park, Dong-Sik;Chung, Hee-Chul;Chung, Jae Youn;Ma, Choong Je
    • Biomolecules & Therapeutics
    • /
    • 제21권5호
    • /
    • pp.405-410
    • /
    • 2013
  • Codonopsis lanceolata (Campanulaceae) traditionally have been used as a tonic and to treat patients with lung abscesses. Recently, it was proposed that the extract and some compounds isolated from C. lanceolata reversed scopolamine-induced memory and learning deficits. The purpose of this study was to evaluate the improvement of cognitive enhancing effect of C. lanceolata by steam and fermentation process in scopolamine-induced memory impairment mice models by passive avoidance test and Morris water maze test. The extract of C. lanceolata or the extract of steamed and fermented C. lanceolata (SFCE) was orally administered to male mice at the doses of 100 and 300 mg/kg body weight. As a result, mice treated with steamed and fermented C. lanceolata extract (SFCE) (300 mg/kg body weight, p.o.) showed shorter escape latencies than those with C. lanceolata extract or the scopolamine-administered group in Morris water maze test. Also, it exerted longer step-through latency time than scopolamine treated group in passive avoidance test. Furthermore, neuroprotective effect of SFCE on glutamate-induced cytotoxicity was assessed in HT22 cells. Only SFCE-treated cells showed significant protection at 500 ${\mu}g/ml$. Interestingly, steamed C. lanceolata with fermentation contained more phenolic acid including gallic acid and vanillic acid than original C. lanceolata. Collectively, these results suggest that steam and fermentation process of C. lanceolata increased cognitive enhancing activity related to the memory processes and neuroprotective effect than original C. lanceolata.

Changes in c-Fos Expression in the Forced Swimming Test: Common and Distinct Modulation in Rat Brain by Desipramine and Citalopram

  • Choi, Sun Hye;Chung, Sung;Cho, Jin Hee;Cho, Yun Ha;Kim, Jin Wook;Kim, Jeong Min;Kim, Hee Jeong;Kim, Hyun Ju;Shin, Kyung Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제17권4호
    • /
    • pp.321-329
    • /
    • 2013
  • Rodents exposed to a 15-min pretest swim in the forced swimming test (FST) exhibit prolonged immobility in a subsequent 5-min test swim, and antidepressant treatment before the test swim reduces immobility. At present, neuronal circuits recruited by antidepressant before the test swim remain unclear, and also less is known about whether antidepressants with different mechanisms of action could influence neural circuits differentially. To reveal the neural circuits associated with antidepressant effect in the FST, we injected desipramine or citalopram 0.5 h, 19 h, and 23 h after the pretest swim and observed changes in c-Fos expression in rats before the test swim, namely 24 h after the pretest swim. Desipramine treatment alone in the absence of pretest swim was without effect, whereas citalopram treatment alone significantly increased the number of c-Fos-like immunoreactive cells in the central nucleus of the amygdala and bed nucleus of the stria terminalis, where this pattern of increase appears to be maintained after the pretest swim. Both desipramine and citalopram treatment after the pretest swim significantly increased the number of c-Fos-like immunoreactive cells in the ventral lateral septum and ventrolateral periaqueductal gray before the test swim. These results suggest that citalopram may affect c-Fos expression in the central nucleus of the amygdala and bed nucleus of the stria terminalis distinctively and raise the possibility that upregulation of c-Fos in the ventral lateral septum and ventrolateral periaqueductal gray before the test swim may be one of the probable common mechanisms underlying antidepressant effect in the FST.

초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용 (Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables)

  • 김영;권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

Efficient Parallel Scan Test Technique for Cores on AMBA-based SoC

  • Song, Jaehoon;Jung, Jihun;Kim, Dooyoung;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권3호
    • /
    • pp.345-355
    • /
    • 2014
  • Today's System-on-a-Chip (SoC) is designed with reusable IP cores to meet short time-to-market requirements. However, the increasing cost of testing becomes a big burden in manufacturing a highly integrated SoC. In this paper, an efficient parallel scan test technique is introduced to minimize the test application time. Multiple scan enable signals are adopted to implement scan architecture to achieve optimal test application time for the test patterns scheduled for concurrent scan test. Experimental results show that testing times are considerably reduced with little area overhead.

박판 스프링용 탄소공구강대(SK5M)의 기계적 성질에 미치는 뜨임 온도의 영향 (The Effects of the Tempering Temperatures on the Mechanical Properties of the Carbon Tool Steel(SK5M) for Flat Spring)

  • 원시태;심경섭;임철록
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2006
  • This study examined the effects of the tempering temperatures($360-420^{\circ}C$) on the mechanical properties of the carbon tool steel (SK4M) for flat spring. Hardness test, tensile test and fatigue test were performed at room temperature($20^{\circ}C$). The tensile strength and yield strength of $390^{\circ}C\;and\;420^{\circ}C$ tempered SK5M were 0.93-0.97 times and 0.81-0.87 times those of $360^{\circ}C$ tempered SK5M, respectively. The fatigue limit of $360-420^{\circ}C$ tempered SK5M were 35-40% of tensile strength of $360-420^{\circ}C$ tempered SK5M, respectively.

  • PDF

노인에서 치매 조기선별을 위한 시각.금전계산 검사의 유용성 (Availability of the Time and Change Test in Screening for Dementia in the Elderly)

  • 정은경;신민호;이정애
    • Journal of Preventive Medicine and Public Health
    • /
    • 제36권2호
    • /
    • pp.101-107
    • /
    • 2003
  • Objectives : Dementia has emerged as a leading public health problem in elderly persons, and its early detection is important for the treatment of curable cases, and in the educational support for other family members. Although dementia screening tests are available, they have not gained widespread use in community or primary care settings. Our goal was to validate the Tine and Change (T&C) Test, -including its validity and reliability in patients, and to assess it as a simple, standardized method for the screening of dementia in the rural elderly. Methods : The participants in this study comprised of 59 patients from an urban hospital and 405 persons from a rural community aged 65 years or older. The time test evaluated the understanding of clock hands indicating 11:10, and the change test the ability to make 1,000 Won from a group of coins, consisting of one 500, seven 100, and seven 50 Won coins. The T&C ratings were validated against a reference standard based on the physician's diagnosis of the patients. The convergent validity in relation to other cognitive measure, test-retest agreement, and inter-observer reliability were assessed. To assess the relationship between the Korean Mini-Mental State Exam (K-MMSE) and the T&C Test, the mean K-MMSE scores were compared with the results of the T&C Test in the elderly from a rural community. Results The T&C Test had a sensitivity and specificity of 73.0, and 90.9%, and positive and negative predictive values of 93.1, and 66.7%, respectively. The test-retest and inter-observer agreement rates were both 95%. The K-MMSE scores and T&C Test were significantly related in the elderly from a rural community (p<0.01), The T&C Test was not influenced by the educational status. The Time and Change Tests took a mean of 6.3 and 12.7 seconds, respectively, to complete Conclusion : The T&C Test is a simple, accurate and reliable, performance-based tool in the screening for dementia. Because it is quick, and easy-to-use, it is hoped the T&C Test will be used for the widespread cognitive screening of aging populations.