• Title/Summary/Keyword: Journal evaluation

Search Result 68,570, Processing Time 0.097 seconds

The Effects of Salt and NaNO2 on Fatty Acid Composition, Free Amino Acids, Microbial Counts and Sensory Characteristics of Dry-cured Ham Processed under Korean Environment (소금과 아질산염 처리수준이 자연숙성 건염햄의 지방산 조성, 유리아미노산, 미생물수 및 관능적 특성에 미치는 영향)

  • Seong, Pil-Nam;Kim, Jin-Hyoung;Cho, Soo-Hyun;Kang, Dong-Woo;Kang, Geun-Ho;Park, Beom-Young;Lee, Jong-Moon;Jung, Jae-Hong;Kim, Dong-Hoon
    • Food Science of Animal Resources
    • /
    • v.30 no.3
    • /
    • pp.435-442
    • /
    • 2010
  • The study analyzed the effects of salt concentration [high salt (HS) and low salt (LS)] and sodium nitrite ($NaNO_2$), which are typically utilized in Korean processing facilities, on fatty acid composition, free amino acids, microbial counts and sensory characteristics of processed dry-cured ham. Four different treatments were considered: three hams (11.30 kg) salted with 92 g/kg salt (w/w) (HS), three hams (10.65 kg) treated with HS and 100 ppm $NaNO_2$ (HS+$NaNO_2$), three hams (11.42 kg) salted with 62 g/kg salt (w/w) (LS), and three hams (10.62 kg) treated with LS and 100 ppm $NaNO_2$ (LS+$NaNO_2$). Fatty acid composition analysis revealed significantly (p<0.05) higher saturated fatty acid and lower (p<0.05) unsaturated fatty acid in the HS+$NaNO_2$ group compared with the other groups. Glutamate, alanine and lysine free amino acids were higher than the other free amino acids. The processing conditions did not significantly affect the free amino acids of biceps femoris muscles, except for the proline content (p>0.05). In sensory evaluation, the fermentation aroma of the LS group was higher than that of the HS group. The aerobic counts consistently ranged from from $2.3{\times}10^2$ to $1.11{\times}10^4$ CFU/g. Escherichia coli including strain O157:H7, Staphylococcus aureus, and Salmonella spp. were not detected.

Analysis of Chinese Consumer Preference of Country of Origin for Apples based on National Organic Certification (사과의 국가별 유기인증 결합에 대한 중국 소비자 선호분석)

  • Kwon, Jae-Hyun;Kim, Jeong-Nyeon;Hong, Na-Kyoung;Kim, Tae-Kyun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.4
    • /
    • pp.225-230
    • /
    • 2014
  • This study investigates the effect of organic certification of apples on consumer preference in China as a way to support the expanded export of Korean apples to China. A choice experiment was designed to analyze the apple consumption in China. A total of 298 Chinese consumers answered the survey, and multinomial logit models were used to analyze the results. Organic certification was identified as an important determinant of consumer preference for apples in China, affecting both the evaluation and choice of country of origin. The results also indicated that Korean organic certification significantly increased the probability of Chinese consumers choosing Korean apples. Thus, organic certification by the Korean government should be strengthened to promote apple exports to China, plus the results of this study may provide useful information to promote agricultural product exports and improve the organic certification system.

EVALUATION OF PERIODONTAL LIGAMENT CELL VIABILITY IN RAT TEETH AFTER FROZEN PRESERVATION USING IN-VIVO MTT ASSAY (급속냉동된 쥐 치아의 in vivo MTT 검색법을 이용한 치주인대세포 활성도 평가)

  • Kim, Jae-Wook;Kim, Eui-Sung;Kim, Jin;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.192-202
    • /
    • 2006
  • The purpose of this study was to examine the viability of PDL cells in rat molars by using in vivo MTT assay, which was used to compare fast cryopreservation group by liquid nitrogen $(-196^{\circ}C)\;with\;4^{\circ}C$ cold preservation group. A total of 74 Sprague-Dawley white female rats of 4 week-old with a body weight of 100 grams were used. The maxillary left and right, first and second molars were extracted as atraumatically as possible under ketamine anesthesia. Ten teeth of each group were divided as six experimental groups depending upon the preservation. Cryopreservation groups were Group 1 (5% DMSO 6% HES in F medium) Group 2 (10% DMSO in F medium), Group 3 (5% DMSO 6% HES in $Viaspan^(R)$). Group 4 (10% DMSO in $Viaspan^(R)$) which were cryopreserved for 1 week and cold preservation groups were Group 5 (F medium) , Group 6 ($Viaspan^(R)$) at $4^{\circ}C$ for 1 week. Immediate extraction group was used as a control. After preservation and thawing, the in vivo MTT assay was processed. Two way ANOVA and Duncan's Multiple Range Test was performed at the 95 % level of confidence, Another 2 teeth of each group were treated as the same manner and frozen sections $10{\mu}m$ thick for microscopic observation. The value of optical density obtained after in vivo MTT analysis was divided by the value of eosin staining for tissue volume standardization. Group 1, 2 had significantly higher optical density than Group 3 and 4 which had the lowest OD value. Group 6 had higher OD value than in Group 5 (P<0.05). Histological findings of periodontal ligament cell, after being stained with MTT solution were consistent with the in vivo MTT assay results. In this study, the groups which were frozen with DMSO as a cryoprotectant and the groups with F medium showed the best results.

MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS (3종 광중합개시제를 함유한 실험용 복합레진의 미세누출도)

  • Kim, Ji-Hoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 ${\mu}m$) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/$cm^2$. Teeth were thermocycled fivehundred times between $50^{\circ}C$and $550^{\circ}C$for 30s at each temperature. Electrical conductivity (${\mu}A$) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (${\mu}A$)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

The evaluation of color and color difference according to the layering placement of Incisal shade composites on the body composites of the indirect resin restoration (간접 수복용 복합레진의 Incisal 색상 적층 두께에 따른 표면 색상 및 색차의 평가)

  • Park, Su-Jung;Lee, Han-Young;Nah, Myong-Yun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the surface color of indirect resin restoration according to the layering placement of different shade of incisal composite. Materials and Methods: In this study, CIE $L^*a^*b^*$ value of 16 Body composite of Tescera ATL (Bisco, Schaumburg IL,USA) was measured by spectrophotometer (NF999, Nippon Denshuku, Japan), and compared to CIE $L^*a^*b^*$ value of Vitapan shade guide. Nine shade Incisal composite of Tescera ATL were buildup to 1 mm thickness on Body composites inlay block, and CIE $L^*a^*b^*$ value was measured. Incisal composite was ground to 0.5 mm thickness and CIE $L^*a^*b^*$ value was re-measured. Color difference between Body composite and Incisal composites layered on Body composite was calculated as a function of thickness. Results: Color difference between corresponding shade of Tescera Body composite and Vitapan shade guide was from 6.88 to 12.80. $L^*$ and $b^*$ value was decreased as layering thickness of Incisal composite on Body composite was increased. But, $a^*$ value did not show specific change tendency. Conclusions: Surface color difference between Body composites and Incisal composites layered on Body composite was increased as the layering thickness of Incisal composite increased (p < 0.05).

THE INFLUENCE OF pH AND LACTIC ACID CONCENTRATION ON THE FORMATION OF ARTIFICIAL ROOT CARIES IN ACID BUFFER SOLUTION (산 완충용액의 pH 및 유산의 농도가 인공치근우식의 형성에 미치는 영향)

  • Oh, Hyun-Suk;Roh, Byoung-Duck;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.47-60
    • /
    • 2007
  • The purpose of this study is to compare and to evaluate the effect of pH and lactic acid concentration on the progression of artificial root caries lesion using polarizing microscope, and to evaluate the morphological changes of hydroxyapatite crystals of the demineralized area and to investigate the process of demineralization using scanning electron microscope. Artificial root caries lesion was created by dividing specimens into 3 pH groups (pH 4.3, 5.0, 5.5), and each pH group was divided into 3 lactic acid concentration groups (25 mM, 50 mM, 100 mM). Each group was immersed in acid buffer solution for 5 days and examined. The results were as follows : 1. Under polarized microscope, the depth of lesion was more effected by the lactic acid concentration rather than the pH. 2. Under scanning electron microscope, dissolution of hydroxyapatite crystals were increased as the lactic acid concentration increased and the pH decreased. 3. Demineralized hydroxyapatite crystals showed peripheral dissolution and decreased size and number within cluster of hydroxyapatite crystals and widening of intercluster and intercrystal spaces as the pH decreased and the lactic acid concentration increased. 4. Under scanning electron microscope evaluation of the surface zone, clusters of hydroxyapatite crystals were dissolved, and dissolution and reattachment of crystals on the surface of collagen fibrils were observed as the lactic acid concentration increased. 5. Under scanning electron microscope, demineralizatlon of dentin occurred not only independently but also with remineralization simultaneously. In conclusion, the study showed that pH and lactic acid concentration influenced the rate of progression of the lesion in artificial root caries. Demineralization process was progressed from the surface of the cluster of hydroxyapatite crystals and the morphology of hydroxyapatite crystals changed from round or elliptical shape into irregular shape as time elapsed.

An Implementation of Dynamic Gesture Recognizer Based on WPS and Data Glove (WPS와 장갑 장치 기반의 동적 제스처 인식기의 구현)

  • Kim, Jung-Hyun;Roh, Yong-Wan;Hong, Kwang-Seok
    • The KIPS Transactions:PartB
    • /
    • v.13B no.5 s.108
    • /
    • pp.561-568
    • /
    • 2006
  • WPS(Wearable Personal Station) for next generation PC can define as a core terminal of 'Ubiquitous Computing' that include information processing and network function and overcome spatial limitation in acquisition of new information. As a way to acquire significant dynamic gesture data of user from haptic devices, traditional gesture recognizer based on desktop-PC using wire communication module has several restrictions such as conditionality on space, complexity between transmission mediums(cable elements), limitation of motion and incommodiousness on use. Accordingly, in this paper, in order to overcome these problems, we implement hand gesture recognition system using fuzzy algorithm and neural network for Post PC(the embedded-ubiquitous environment using blue-tooth module and WPS). Also, we propose most efficient and reasonable hand gesture recognition interface for Post PC through evaluation and analysis of performance about each gesture recognition system. The proposed gesture recognition system consists of three modules: 1) gesture input module that processes motion of dynamic hand to input data 2) Relational Database Management System(hereafter, RDBMS) module to segment significant gestures from input data and 3) 2 each different recognition modulo: fuzzy max-min and neural network recognition module to recognize significant gesture of continuous / dynamic gestures. Experimental result shows the average recognition rate of 98.8% in fuzzy min-nin module and 96.7% in neural network recognition module about significantly dynamic gestures.

Design and Implementation of Quality Broker Architecture to Web Service Selection based on Autonomic Feedback (자율적 피드백 기반 웹 서비스 선정을 위한 품질 브로커 아키텍처의 설계 및 구현)

  • Seo, Young-Jun;Song, Young-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.223-234
    • /
    • 2008
  • Recently the web service area provides the efficient integrated environment of the internal and external of corporation and enterprise that wants the introduction of it is increasing. Also the web service develops and the new business model appears, the domestic enterprise environment and e-business environment are changing caused by web service. The web service which provides the similar function increases, most the method which searches the suitable service in demand of the user is more considered seriously. When it needs to choose one among the similar web services, service consumer generally needs quality information of web service. The problem, however, is that the advertised QoS information of a web service is not always trustworthy. A service provider may publish inaccurate QoS information to attract more customers, or the published QoS information may be out of date. Allowing current customers to rate the QoS they receive from a web service, and making these ratings public, can provide new customers with valuable information on how to rank services. This paper suggests the agent-based quality broker architecture which helps to find a service providing the optimum quality that the consumer needs in a position of service consumer. It is able to solve problem which modify quality requirements of the consumer from providing the architecture it selects a web service to consumer dynamically. Namely, the consumer is able to search the service which provides the optimal quality criteria through UDDI browser which is connected in quality broker server. To quality criteria value decision of each service the user intervention is excluded the maximum. In the existing selection architecture, the objective evaluation was difficult in subjective class of service selecting of the consumer. But the proposal architecture is able to secure an objectivity with the quality criteria value decision where the agent monitors binding information in consumer location. Namely, it solves QoS information of service which provider does not provide with QoS information sharing which is caused by with feedback of consumer side agents.

The Validation Study of Beck Depression Scale 2 in Korean Version (한국판 벡 우울 척도 2판의 타당화 연구)

  • Lim, Sun-Young;Lee, Eun-Jeong;Jeong, Seong-Won;Kim, Hee-Chul;Jeong, Cheol-Ho;Jeon, Tae-Yeon;Yi, Min-Soo;Kim, Jae-Min;Jo, Hyeon-Ju;Kim, Jeong-Beom
    • Anxiety and mood
    • /
    • v.7 no.1
    • /
    • pp.48-53
    • /
    • 2011
  • Objective : Korean Version of Beck-II Depression Inventory to verify the reliability and validity of the proposed standards are practical and standardized, cut-off score by establishing a baseline indicating the presence of depression and depression On in the evaluation was to evaluate the clinical usefulness. Methods : 739 patients with major depression using the SCID and normal controls were 302 study subjects. Of patients with clinically significant medical condition, or psychotic disorders, organic mental disorder, epilepsy or seizure disorder, eating disorders are associated with patients taking anti-convulsants experienced in the past, patients were excluded from the study. Results : The main findings of this study were as follows. First, with respect to the KBDI-II items, the correlation between them ranged from 0.51 to 0.74, and was 0.60 over all questions. Further, the overall correlation of the KBDI-II plates showing confidence 'normal' than it was verified that. Second, the BDIII was used in each group to examine internal consistency and thus, whether Cronbach's alpha values were greater than 0.94. Third, the principal component analysis sought to extract factors in a way consistent with the results inspected last 3 factors were extracted and the total variance explained was 47.3%. Fourth, the Cutting calculated the score on the KBDI-II for ROC (Receiver operator characteristic) analysis yielding 18 dot, with the highest sensitivity and specificity was seen. Conclusion : Based on the results of this Study, the KBDI-II cut-off point should be valid as prescribed in 18 is considered.