Browse > Article
http://dx.doi.org/10.5395/JKACD.2009.34.4.333

MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS  

Kim, Ji-Hoon (Department of Conservative Dentistry, College of Dentistry, Dankook University)
Shin, Dong-Hoon (Department of Conservative Dentistry, College of Dentistry, Dankook University)
Publication Information
Restorative Dentistry and Endodontics / v.34, no.4, 2009 , pp. 333-339 More about this Journal
Abstract
This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 ${\mu}m$) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/$cm^2$. Teeth were thermocycled fivehundred times between $50^{\circ}C$and $550^{\circ}C$for 30s at each temperature. Electrical conductivity (${\mu}A$) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (${\mu}A$)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.
Keywords
Microleakage; Composite resin; Photoinitiation; Electrical conductivity; Thermocycling;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Stansbury JW. Curing dental resins and composites by photopolymerization. J Esthet Dent 12:300-308, 2000   DOI   PUBMED
2 Rueggeberg FA, Ergle JW, Lockwood PE. Effect of photinitiator level on properties of a light-cured and post-cured heated model resin system. Dent Mater 13:360-364, 1997   DOI   ScienceOn
3 Ferracane JL, Mitchem JC. Relationship between com-posite contraction stress and leakage in Class V cavities. Am J Dent 16(4):239-243, 2003
4 구봉주, 신동훈. 법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향. 대한치과보존학회지 31(6):452-459, 2006   DOI
5 Tantbirojn D, Versluis A, Pintado MR, DeLong R, Douglas WH. Tooth deformation patterns in molars after composite restoration. Dent Mater 20:535-542, 2004   DOI   ScienceOn
6 박정원. Nanofilled 복합레진의 잔류응력 비교. 대한치과보존학회지 33(5):457-462, 2008   DOI
7 Hannig M, Friedrichs C. Comparative in vivo and in vitro investigation of interfacial bond variability. Oper Dent 26(1):3-11, 2001   PUBMED
8 Jacobsen PH, Von Fraunhofer JA. Assessment of microleakage using a conductimetric technique. J Dent Res 54(1):41-48, 1976   PUBMED
9 Mattison GD, Von Fraunhofer JA. Electrochemical microleakage study of endodontic sealer/cements. Oral Surg Oral Med Oral Pathol 55:402-407, 1983   DOI   ScienceOn
10 Frankenberger R, Strobel WO, Lohbauer U, Kramer N, Petschelt A. The effect of six years of water storage on resin composite bonding to human dentin. J Biomed Mater Res B Appl Biomater 69:25-32, 2004   DOI
11 Cohen SG, Chao HM, Photoreduction of aromatic ketones by amine. Studies of quantum yields and mechanism. J Am Chem Soc 90:165-173, 1968   DOI
12 Inano H, Ohba H, Tamaoki B. Photochemical inactivation of human placental estradiol 17 beta-hydrogenase in the presence of 2,3-butandion. J Steroid Biochem 19:1617-1622, 1983   DOI   ScienceOn
13 Gladys S, Meerbeer VB, Lambrechts P, Vanherle G. Microleakage of adhesive restorative materials. Am J Dent 14(3):170-176, 1994   PUBMED
14 Crim GA, Chapman KW. Reducing microleakage in Class V restorations: an in vitro study. Quint Int 25(11):781-785, 1994   PUBMED
15 Ferracane JL, Mitchem JC, Condon JR, Todd R. Wear and marginal breakdown of composites with various degrees of cure. J Dent Res 76:1508-1516, 1997   DOI   ScienceOn
16 Wataha JC, Hanks CT, Strawn S, Fat GC. Cytotoxicity of components of resins and other dental restorative materials. J Oral Rehab 21:453-462, 1994   DOI   ScienceOn
17 Ferracane JL, Greener EH. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins. J Biomed Mater Res 20(1):121-131, 1986   DOI   ScienceOn
18 Antonucci JM, Venz S. Tertiary amine salts and complexes as chemical and photochemical accelerators. J Dent Res 66:128 Abstr. No. 170, 1987
19 Braga RR, Ferracane JL. Contraction stress related to degree of conversion and reaction kinetics. J Dent Res 81(2):114-118, 2002   DOI   ScienceOn
20 Shin DH, Rawls HR. Degree of conversion and color stability of the light curing resin with new photoinitiator systems. Dent Mater (in press), 2009   DOI   ScienceOn
21 Delivanis PD, Chapman KA. Comparison and reliability of techniques for measuring leakage and marginal penetration. Oral Surg Oral Med Oral Pathol 53:410-416, 1982   DOI   ScienceOn
22 Iwami Y, Yamamoto H, Ebisu S. A new electrical method for detecting marginal leakage of in vitro resin restorations. J Dent 28:241-247, 2000   DOI   ScienceOn
23 Mazato S, Tarumi H, Kobayashi K, Hiraguri H, Oda K, Tsuchitani Y, Relationship between the degree of conversion and internal discoloration of light-activated composite. Dent Mat J 14:23-30, 1995   DOI   PUBMED   ScienceOn
24 Labella R, Lambrechts P, Van Meerbeek B. Vanherle G. Polymerization shrinkage and elasticity of flowable composites and filled adhesives. Dent Mater 15: 128-137, 1999   DOI   ScienceOn
25 Brannstrom M. Communication between the oral cavity and the dental pulp associated with restorative treatment. Oper Dent 9:57- 68, 1984   PUBMED
26 Ferracane JL. Elution of leachable components from composites. J Oral Rehab 21:441-452, 1994   DOI   PUBMED   ScienceOn
27 Ridtschel RL. Contact allergens in ultraviolet-cured acrylic resin system. Occupational Med 1:301-306, 1986   PUBMED
28 Davidson CL, Feilzer AJ. Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives. J Dent 25:435-440, 1997   DOI   ScienceOn
29 Nakano Y. A new electrical testing method on marginal leakage of composite resin restorations. Japan J Cons Dent 8:1183-1198, 1985
30 Eick JD, Kostoryz EL, Rozzi SM, Jacobs DW, Oxman JD, Chappelow CC, Glaros AG, Yourtee DM. In vitro biocompatibility of oxirane/polyol dental composites with promising physical properties. Dent Mater 18:413-421, 2002   DOI   ScienceOn
31 Park YJ, Chae KH, Rawls HR. Development of a new photoinitiation system for dental light-cure composite resin. Dent Mater 15:120-127, 1999   DOI   ScienceOn
32 Peutzfeldt A, Asmussen E. In vitro wear, hardness, and conversion of diacetyl-containing resin materials. Dent Mater 12:103-108, 1996   DOI   ScienceOn
33 김창윤, 신동훈. 열순환 횟수에 따른 복합레진의 미세누출. 대한치과보존학회지 32(4):377-384, 2007   DOI
34 Gale MS, Darvell BW, Cheung GS. Three-dimensional reconstruction of microleakage pattern using a sequential grinding technique. J Dent 22(6):370-375, 1994   DOI   ScienceOn
35 Peutzfeldt A, Asmussen E. Influence of ketones on selected mechanical properties. J Dent Res 71:1847-1850, 1992   DOI   PUBMED   ScienceOn
36 Puppala R, A. Heged A, Munshi AK, Laser and light cured composite resin restoration : in-vitro comparison of isotope and dye penetration. J Clin Pediatric Dent 20:213-218, 1996