• 제목/요약/키워드: Joule effect

검색결과 77건 처리시간 0.04초

An E-score Development Methodology for Life Cycle Impact Assessment

  • Young-Min Park;Jai-Rip Cho
    • 산업경영시스템학회지
    • /
    • 제24권68호
    • /
    • pp.51-65
    • /
    • 2001
  • This study is to make LCIA(Life Cycle Impact Assessment) easier as a methodology of environmental scores(called E-score) that integrated environmental load of each emission substance based on environmental damage such as in human health, ecosystem and resources category. The concept is to analyzes the LCI(Life Cycle Inventory) and defines the level of environment damages for human health, ecosystem and resources to objective impact assessment standard, and makes the base of marginal damage to calculate the damage factor, which can present the indication that can establish the standard value of environmental impact. First, damages to human health are calculated by fate analysis, effect analysis and damage analysis to get the damage factor of health effect as a DALY(Disability Adjusted Life Years) unit. Second, damages to ecosystem are calculated by fate analysis, effect analysis and damage analysis to get the damage factor of the effect as a PDF(Potentially Disappeared Fraction) unit through linking potentially increased disappeared fraction. Third, damages to resources are carried out by resource analysis and damage analysis for linking the lower fate to surplus energy conception to get damage factor as a MJ(Mega Joule) unit. For the ranking of relative environment load level each other, LCIA can be carried out effectively by applying this E-score methodology to the particular emission substances. A case study has been introduced for the emission substances coming out of a tire manufacturer in Korea. It is to show how to work the methodology. Based on such study result, product-designers or producers now can apply the E-scores presented in this study to the substances of emission list, and then calculate the environment load of the product or process in advance at any time and can see the environment performance comparatively and expected to contribute to the environmental improvement in view of environmental pollution prevention.

  • PDF

자유유동 전기이동법에 의한 대두단백질 분리 (Separation of Soybean Protein by Free-flow Electrophoresis)

  • 한재갑;류화원
    • KSBB Journal
    • /
    • 제10권1호
    • /
    • pp.63-70
    • /
    • 1995
  • 실험실에서 자체 제작한 자유유통 전기이동 장치 에서 등전집속법을 이용한 대두 단백질의 분리를 통 해 운전 조건들이 분리에 미치는 영향을 조사하였 다. 매 실험마다 pH, 전기전도도, uv 흉광도 (280nm) 등을 측정하였고 시료의 순도는 SDS­P PAGE 분석을 통해 점검하였다. Tris와 boric acid로 처리한 대두단백질 추출액에 g glutamic acid, histidine, argmme, glycine 등 아 미노산 각 ImM과 dipeptide로 glycyl-glycine 2mM, 배경 전해액으로서 KCI ImM로 구성된 시료 의 완충액을 혼합하여 시료로 사용하였다. 분리막을 셀룰로오스 아세테이트를 사용할 경우 pH는 양극쪽에서 3, 음극쪽에서 8 정도의 값을 보였으며 2개의 변곡점을 나타내었다. 가해준 전압은 3 300V에서 lOOOV의 범위였으며 전압이 높을수록 더 나은 분리도를 얻었으나 전압을 더 높일 경우 과도한 Joule열의 발생으로 인해 한계가 있었다. 시간이 지남에 따라 단백질들은 분리조 중앙 부근에서 집속이 일어났으며 pH와 전기전도도의 변화로부터 분리 조내의 이온들이 막을 통해 전극쪽으로 이통해 가고 있음을 알 수 있었다. 완충용액의 농도를 5배로 증 가시킬 경우 300V에서 좋은 집속을 얻었으냐 10배 이상으로 농도를 높일 경우에는 분리조 입구와 출구 의 유체 온도차가 $25^{\circ}C$ 이상이 되어 단백질의 변성 이 일어날 수 있어 더 높일 수 없었다. 이온교환막을 사용할 경우 이온의 분극화현상을 일으켜 U자 형태 의 전기전도도 분포를 나타내었다. 아미노산 혼합물 대신 상용의 ampholyte를 사용하더라도 분리도에 있어 큰 차이가 없었다.

  • PDF

히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석 (Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation)

  • 성태홍;김경훈;한상조;김경천
    • 한국가스학회지
    • /
    • 제18권4호
    • /
    • pp.13-20
    • /
    • 2014
  • 상업용 천연가스 배급 시스템에서 천연가스의 공급압력은 압력조절밸브를 사용하여 제어하며 이때 막대한 압력에너지가 낭비된다. 이러한 폐압에너지는 터보 팽창기와 같은 터보기계를 사용하여 회수할 수 있으나 팽창과정에서 발생하는 Joule-Thompson 효과에 따라서 큰 온도강하가 발생한다. 터보 팽창기 전단 또는 후단에 보일러를 설치하여 영하의 온도를 방지할 수 있으며 또한 보일러를 대체하여 연료전지나 가스엔진의 폐열을 이용하여 천연가스를 예열할 수도 있으나 하이브리드 시스템의 구동을 위해 운영규모에 따라 일정량을 소모해야 한다. 이 연구에서는 천연가스가 가지고 있는 압력에너지를 활용하여 천연가스의 소모 없이 터보 팽창기와 연결된 히트펌프를 구동하여 천연가스를 예열하는 시스템을 제안하고 증발온도, 응축온도 및 작동유체의 변화에 따른 시스템의 열역학적 특성을 분석하였다. R717 냉매가 예상 작동범위 내에서 가장 높은 COP와 가장 낮은 압축일을 나타내 제안된 하이브리드 시스템에 적합함을 확인하였다. 보일러시스템과의 경제성 분석을 통해 천연가스를 LNG 형태로 수입하고 있는 국내의 경우 히트펌프 하이브리드 시스템이 경쟁력 있음을 확인하였다.

카본블랙 첨가 PMC(Polyethylene Matrix Composites)의 문턱스며들기(Percolation Threshold)와 절연파괴 강도 임계지수 (Percolation Threshold and Critical Exponent of Dielectric Breakdown Strength of Polyethylene Matrix Composites added Carbon Black)

  • 신순기
    • 한국재료학회지
    • /
    • 제21권9호
    • /
    • pp.477-481
    • /
    • 2011
  • Composites of insulating polyethylene and carbon black are widely used in switching elements, conductive paint, and other applications due to the large gap of resistance value. This research addresses the critical exponent of dielectric breakdown strength of polymer matrix composites (PMC) made with carbon black and polyethylene below the percolation threshold (Pt) for the first time. Here, Pt means the volume fraction of carbon black of which the resistance of the PMC is transferred from its sharp decrease to gradual decrease in accordance with the increase of carbon-black-filled content. First, the Pt is determined based on the critical exponents of resistivity and relative permittivity. Although huge cohesive bodies of carbon black are formed in case of being less than the Pt, a percolation path connecting the conducting phases is not formed. The dielectric breakdown strength (Dbs) of the PMC below Pt is measured by using an impulse voltage in the range from 10 kV to 40 kV to avoid the effect of joule heating. Although the observed Dbs data seems to be well fitted to a straight line with a slope of 0.9 on a double logarithm of (Pt-$V_{CB}$) and Dbs, the least squares method gives a slope of 0.97 for the PMC. It has been found that finite carbon-black clusters play an important role in dielectric breakdown.

AC4A 합금의 충격특성 및 피로특성에 미치는 스크랩 함량의 영향 (Effect of Scrap Content on the Impact Property and Fatigue Property of AC4A Alloy)

  • 김헌주
    • 한국주조공학회지
    • /
    • 제36권6호
    • /
    • pp.187-194
    • /
    • 2016
  • The effects of scrap content on the impact and fatigue properties were investigated in AC4A alloy. The impact absorbed energy of as-cast specimens were 3.61, 3.56, 3.47, and 3.08 Joules, respectively, when scrap contents of the specimens were 0, 20, 35, and 50%. And, the corresponding energy levels of the T6 heat-treated condition were 3.66, 3.48, 3.25, and 2.96 Joule. In the same way, the fatigue strength values of the as-cast specimens were 53.2, 52.0, 48.4, and 43.8MPa, respectively, and the corresponding fatigue strengths of the T6 heat-treatment specimens were 85.4, 75.7, 60.6, and 51.2 MPa. Impact absorbed energy and fatigue strength decreased as scrap content of the specimen increased. It is assumed that impact absorbed energy decreased owing to the presence of oxide films, which act as branches of 2nd cracks; fatigue strength also decreased with decreased deflection of the fatigue crack path as the scrap content of the specimens increased.

축방향 자기장에 의한 대전류 아크 특성에 관한 연구 (A Study on the Characteristics of High-Current Arc Plasma Influenced by Axial Magnetic Field)

  • 조성훈;이종철;최명준;권중록;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2515-2518
    • /
    • 2008
  • The vacuum interrupter (VI) is widely used in medium-voltage switching circuits due to its abilities and advantages as an environmental friendly circuit breaker. An understanding of the vacuum arc flow phenomena is very important for improving the performance of vacuum interrupter. In order to closely examine the vacuum arc phenomena, it is necessary to predict the magnetohydrodynamic (MHD) characteristics by the multidisciplinary numerical modeling, which is coupled with the electromagnetic and the thermal flow fields, simultaneously. In this study, we have investigated arc plasma constriction phenomena and an effect of AMF on the arc plasma with the high-current vacuum arcs for the cup-type AMF electrode by using a commercial finite element analysis (FEA) package, ANSYS. The simulation results applied with various AMFs and constant Joule heat generation show that strong axial magnetic field (AMF) permits the arc to be maintained in a diffused mode to a high-current vacuum arc. However, further studies are required on the two-way coupling method and radiation model for arc plasma in order to accomplish the advanced analysis method.

  • PDF

Spectrum analysis of acoustic Barkhausen noise on neutron irradiated material

  • Sim Cheul-Muu;Park Seung-Sik;Park Duck-Gum;Lee Chang-Hee
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.231-234
    • /
    • 2000
  • In relation to a non-destructive evaluation of irradiation damage of micro-structure of interstitial, void and dislocation, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of reactor pressure vessel was irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$ $(E\ge1MeV)$ at $288^{\circ}C.$The saturation magnetization of neutron irradiated metal did not change. Neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by neutron irradiation. The spectrum of Barkhausen noise was analyzed with an applied frequency of 4Hz and 8Hz, and a sampling time of 50 $\mu$ sec and 20 $\mu$ sec. The harmonic frequency of Joule effect shows 4Hz, 8Hz, 12Hz and 16Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared for the irradiated specimen. Harmonic frequency of induced voltage of sinusoidal magnetic field And Spectrum of Barkhausen noise on material is determined.

  • PDF

모델링 및 시뮬레이션을 통한 수소충전 프로토콜 영향인자 평가 (Evaluation of Influential Factors of Hydrogen Fueling Protocol by Modeling and Simulation)

  • 채충근;강수연;김한나;채승빈;김용규
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.513-522
    • /
    • 2019
  • It is not easy to refuel quickly and safely with 70 MPa hydrogen. This is because the temperature in the vehicle tank rises sharply due to Joule-Thomson effect, etc. Thus protocols such as SAE J2601 in the United States and JPEC-S 0003 in Japan were established. However, they have the problem of over-complexity and lack of versatility by setting the preconditions for hot and cold cases and introducing a number of look-up tables. This study was conducted with the ultimate goal of developing new protocols based on complete real-time communication. Thermodynamic models were made and programs were developed for hydrogen refueling simulations. Simulation results confirmed that there are five parameters in the influencing factors of the hydrogen refueling protocol.

플립칩 Sn-3.5Ag 솔더범프의 Electromigration과 Thermomigration 특성 (Electromigration and Thermomigration Characteristics in Flip Chip Sn-3.5Ag Solder Bump)

  • 이장희;임기태;양승택;서민석;정관호;변광유;박영배
    • 대한금속재료학회지
    • /
    • 제46권5호
    • /
    • pp.310-314
    • /
    • 2008
  • Electromigration test of flip chip solder bump is performed at $140^{\circ}C$ C and $4.6{\times}10^4A/cm^2$ conditions in order to compare electromigration with thermomigration behaviors by using electroplated Sn-3.5Ag solder bump with Cu under-bump-metallurgy. As a result of measuring resistance with stressing time, failure mechanism of solder bump was evaluated to have four steps by the fail time. Discrete steps of resistance change during electromigration test are directly compared with microstructural evolution of cross-sectioned solder bump at each step. Thermal gradient in solder bump is very high and the contribution of thermomigration to atomic flux is comparable with pure electromigration effect.

Experimental Investigation of Output Current Variation in Biased Silicon-based Quadrant Photodetector

  • Liu, Hongxu;Wang, Di;Li, Chenang;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.273-276
    • /
    • 2020
  • We report on the relationship between output current for quadrant photodetector (QPD) and bias voltage in silicon-based p-i-n (positive-intrinsic-negative) QPD examined using millisecond pulse laser (ms pulse laser) irradiation. The mechanism governing the relationship was further studied experimentally. The output current curves were obtained by carrying out QPD under different bias voltages (0-40 V) irradiated by ms pulse laser. Compared to other photodetectors, the relaxation was created in the output current for QPD which is never present in other photodetectors, such as PIN and avalanche photodetector (APD), and the maximum value of relaxation was from 6.8 to 38.0 ㎂, the amplitude of relaxation increases with bias value. The mechanism behind this relaxation phenomenon can be ascribed to the bias voltage induced Joule heating effect. With bias voltage increasing, the temperature in a QPD device will increase accordingly, which makes carriers in a QPD move more dramatically, and thus leads to the formation of such relaxation.