• 제목/요약/키워드: Joule effect

검색결과 77건 처리시간 0.024초

Hall Effect on Unsteady Hartmann Flow with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권8호
    • /
    • pp.1302-1308
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.

다이내믹 스피커에서 폴피스 구멍에 의한 음향특성연구 (The acoustical effect due to the hole of pole piece for by dynamic speaker)

  • 오세진
    • 한국음향학회지
    • /
    • 제37권5호
    • /
    • pp.317-322
    • /
    • 2018
  • 다이내믹 스피커에서 보이스 코일에 전류가 입력되면 Joule 효과에 의해 많은 열이 발생하게 된다. 이 열을 자기회로의 밖으로 방출하기 위하여 폴피스의 중앙에 구멍을 뚫기도 한다. 이 구멍은 열의 방출뿐만 아니라, 다이내믹 스피커의 음향특성도 변화시킬 수 있는 원인이 되기도 한다. 특히 공명주파수가 구멍의 지름과 정비례하여 증가하는 반면에, 구멍의 길이에 반비례하는 것을 알 수 있었다. 이러한 결과들은 위상반전형 스피커시스템의 기계적 등가회로 해석에 따른 이론적 예측과 정확하게 일치하였다. 따라서 다이내믹 스피커의 폴피스에 존재하는 구멍은 위상반전형 스피커시스템에서의 덕트로 취급할 수 있다.

온도기울기 농축(TGF) 향상을 위한 미세채널 형상 최적화 연구 (Geometric Optimization of a Microchannel for the Improvement of Temperature Gradient Focusing)

  • 한태헌;김선민
    • 한국유체기계학회 논문집
    • /
    • 제14권2호
    • /
    • pp.17-24
    • /
    • 2011
  • Temperature gradient focusing (TGF) of analytes via Joule heating is achieved when electric field is applied along a microchannel of varying width. The effect of varying width of the microchannel for the focusing performance of the device was numerically studied. The governing equations were implemented into a quasi-1D numerical model along a microchannel. The validity of the numerical model was verified by a comparison between numerical and experimental results. The distributions of temperature, velocity, and concentration along a microchannel were predicted by the numerical results. The narrower middle width and wider outside width of the channel having the fixed length contribute to improve the focusing performance of the device. However, too narrow middle width of the channel generates a higher temperature which can cause the problems including sample denaturation and buffer solution boiling. Therefore, the channel geometry should be optimized to prevent these problems. The optimal widths of the microchannel for the improvement on TGF were proposed and this model can be easily applied to lab-on-a-chip (LOC) applications where focusing is required based on its simple design.

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

녹차추출물에 의한 쥐표피의 효소에 대한 항산화 효과 (Antioxidant Effect of Green Tea Extracts on Enzymatic Activities of Hairless Mice Skin Induced by Ultraviolet B Light)

  • 류병호;박춘옥
    • 한국식품과학회지
    • /
    • 제29권2호
    • /
    • pp.355-361
    • /
    • 1997
  • 털없는 쥐표피를 적출하여 ultraviolet B로서 조사한 후 녹차의 열수 추출물이 표피의 효소의 활성에 대한 항산화 효과를 조사하였다. 녹차의 열수추출물을 5, 25, 50 및 $100\;{\mu}g$으로 쥐표피에 첨가한 후 ultraviolet B을 $1.0\;joule/cm^{2}$로 조사한 후 효소활성을 조사한 결과 catalase와 glutathione reductase는 녹차의 열수 추출물의 첨가용량이 증가할수록 영향을 미치는 것으로 나타났으나 glutathione peroxidase와 superoxide dismutase는 영향을 받지 않았다. 한편 lipoxygenase의 활성을 알아보기 위하여 arachidonic acid에 $50\;{\mu}g$ 녹차의 열수 추출물을 첨가하여 대사를 검토한 결과 대사산물 12 또는 15-hydroxyeicosa- tetraenoic acid보다 5-HETE 및 8-HETE가 억제되었다. 녹차의 열수 추출물을 5, 25, 50 및 $100\;{\mu}g$ 첨가하였을 때 5-HETE는 각각 32, 52, 62 및 80% 억 제되었고 8-HETE는 각각 36, 47, 70 및 84%로 억제됨을 알 수 있었다.

  • PDF

UNSTEADY HARTMANN FLOW WITH HEAT TRANSFER IN THE PRESENCE OF UNIFORM SUCTION AND INJECTION

  • Attia Hazem A.
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to a constant pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the magnetic field and the uniform suction and injection on both the velocity and temperature distributions is examined.

  • PDF

만성 폐질환 환자에서의 호흡재활치료의 효과 (The Effect of Pulmonary Rehabilitation in Patients with Chronic Lung Disease)

  • 최강현;박영주;조원경;임채만;이상도;고윤석;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권5호
    • /
    • pp.736-745
    • /
    • 1996
  • 배경: 호흡재활치료는 만성 폐질환 환자들의 폐기능을 호전시키지는 못하나 운동허용능(exercise tolerance)을 호전시키는 것으로 알려져 있다. 그러나 이러한 운동허용능이 증가하는 것이 유산소운동 능력 (aerobic exercise capacity)이 중가하기 때문인지는 논란이 있으며, 아직 국내에서 는 호흡재활치료에 대한 보고가 없었다. 방법: 14명의 만성 폐질환 환자(만성폐쇄성폐질환 11명, 유육종증 1명, 기관지확장증 1명, 특발성 폐섬유화증 1명, 평균 연령 $57{\pm}4$세, 남자 12명, 여자 2명)를 대상으로 6 주간의 호흡재활치료를 시행하여 치료 전후의 폐기능과 운동허용능의 변화를 관찰하였다. 결과: 1) 대상 환자의 호흡재활치료 전 평균 노력성 폐활량(FVC), 1초간 노력성호기량($FEV_1$) 및 노력성 호기중간 기류량($FEF_{25-75%}$)은 각각 예측치의 $71.5{\pm}6.4%$, $40.6{\pm}3.4%$$19.3{\pm}3.8%$ 였으며, 총 폐용량(TLC), 기능적잔기용량(FRC) 및 잔기량(RV)은 각각 $130.3{\pm}9.3%$, $157.3{\pm}13.2%$$211.1{\pm}23.9%$이었고, 확산능(diffusing capacity) 및 최대 환기량(MVV)은 각각 $59.1{\pm}1.1%$$48.6{\pm}6.2%$이었다. 이들 각 폐기능의 지표들은 호흡재활치료 전후 유의한 변화는 없었다. 2) 자전거운동력측정계 (bicycle ergometer)를 이용한 운동부하 검사상 최대 운동량(maximum work rate)은 치료전 $57.7{\pm}4.9$ watts 에서 치료후 $64.8{\pm}6.0$ watts로(P=0.036), 최대산소섭취량($VO_2$ max)은 $0.81{\pm}0.07$ L/mm에서 $0.96{\mu}0.08$ L/mm로 (P=0.004), 무산소역치 (anaerobic threshold)는 $0.60{\pm}0.06$ L/mm 에서 $0.76{\mu}0.06$ L/min로(P=0.009) 호흡재활치료후 유의하게 증가하였다. 가스교환은 호흡재활치료 전후에 변화가 없었다. 3) 지구력시험 (endurance test)상 운동일(work)이 상지는 $4.5{\pm}0.7$ joule 에서 $14.8{\pm}2.4$ joule로 (P<0.001), 하지는 $25.4{\pm}5.7$ joule에서 $42.6{\pm}7.7$로 (P<0.001) 모두 재활치료 후 유의하게 증가하였다. 6분 보행거리는 $392{\pm}35$ 미터 에서 $459{\pm}33$ 미터로(P<0.001) 치료 후 연장되었고, 최대 흡기압도 $68.5{\pm}5.4$ $CmH_2O$에서 $80.4{\pm}6.4$ $CmH_2O$로 증가하였다(P<0.001). 결론: 만성 폐질환 환자에서 6주간의 호흡재활치료는 폐기능 및 가스교환을 호전시키지는 못하였지만 운동허용능(exercise tolerance)을 호전시키는 것으로 사료되었다.

  • PDF

Effects of Temperature Amplitude and Loading Frequency on Alternating Current - Induced Damage in Cu Thin Films

  • Park Yeung-Bae
    • 마이크로전자및패키징학회지
    • /
    • 제12권2호
    • /
    • pp.135-140
    • /
    • 2005
  • Although it was recently observed that severe fatigue damage was formed in Al or Cu interconnects due to the cyclic temperatures generated by Joule heating of the metal lines by the passage of alternating currents (AC), AC loading frequency effect on the damage evolution characteristics are not known so far. This work focused on the effect of AC loading frequency (100 Hz vs. 10 kHz) on the thermo-mechanical fatigue characteristics by using polycrystalline sputtered Cu lines with temperature cycles with amplitudes from 100 to $300^{\circ}C$. It was consistently observed that higher loading frequency accelerated damaged grain growth and led to earlier failure irrespective of Cu grain sizes. The frequency effect is believed to result from differences in the concentration of defects created by the deformation-induced motion of dislocations to the grain boundaries.

  • PDF

턴널링 전류효과를 이용한 마이크로가속도 센서의 축전기부 해석 (Analysis in Capacitor of Microaccelerometer Sensor Using Tunnelling Current Effect)

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제3권4호
    • /
    • pp.57-62
    • /
    • 1999
  • The microaccelerometer using a tunnelling current effect concept has the potential of high performance, although it requires slightly complex signal-processing circuit for servo-system. The paddle of micro accelerometer is pulled to have the gap width of about 2nm which almost allows the flow tunnelling current. This paper demonstrates at capacitor of microaccelerometer the use of the coupled thermo-electric analysis for voltage, current, heat flux and Joule heating then tunnelling current flows. Two electrodes are applied to the microaccelerometer producing a unform difference of temperature gradient and electric potential between the paddle and the substrate.

  • PDF

Hall Effect on Unsteady Couette Flow. with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia HazemAIi
    • Journal of Mechanical Science and Technology
    • /
    • 제19권11호
    • /
    • pp.2053-2060
    • /
    • 2005
  • The unsteady Couette flow of an electrically conducting, V1SCOUS, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.