• Title/Summary/Keyword: James

Search Result 1,136, Processing Time 0.023 seconds

Infrared and Radio observations of a small group of protostellar objects in the molecular core, L1251-C

  • Kim, Jungha;Lee, Jeong-Eun;Choi, Minho;Bourke, Tyler L.;Evans II, Neal J.;Di Francesco, James;Cieza, Lucas A.;Dunham, Michael M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.67.4-68
    • /
    • 2015
  • We present a multi-wavelength observational study of a low-mass star-forming region, L1251-C, with observational results at wavelengths from the near-infrared to the millimeter. Spitzer Space Telescope observations confirmed that IRAS 22343+7501 is a small group of protostellar objects. The extended emission to east-west direction with its intensity peak at the center of L1251A has been detected at 350 and 850 mm with the CSO and JCMT telescopes, tracing dense envelope materials around L1251A. The single-dish data from the KVN and TRAO telescopes show inconsistencies between the intensity peaks of several molecular line emission and that of the continuum emission, suggesting complex distributions of molecular abundances around L1251A. The SMA interferometer data, however, show intensity peaks of CO 2-1 and $^{13}CO$ 2-1 located at the position of IRS 1, which is both the brightest source in IRAC image and the weakest source in the 1.3 mm dust continuum map. IRS 1 is the strongest candidate for being the driving source of a newly detected the compact CO 2-1 outflow. Over the whole region ($14^{\prime}{\times}14^{\prime}$) of L125l-C, 3 Class I and 16 Class II sources have been detected, including three YSOs in L1251A. A comparison with the average projected distance among 19 YSOs in L1251-C and that among 3 YSOs in L1251A suggests L1251-C is an example of low-mass cluster formation, where protostellar objects are forming in a small group.

  • PDF

DEEP-South: Round-the-clock Census of Small bodies in the Southern Sky

  • Moon, Hong-Kyu;Kim, Myung-Jin;Yim, Hong-Suh;Choi, Young-Jun;Bae, Young-Ho;Roh, Dong-Goo;Ishiguro, Masateru;Mainzer, Amy;Bauer, James;Byun, Yong-Ik;Larson, Steve;Alcock, Charles
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.56.3-57
    • /
    • 2015
  • As of early 2015, more than 12,000 Near-Earth Objects (NEOs) have been catalogued by the Minor Planet Center, however their observational properties such as broadband colors and rotational periods are known only for a small fraction of the population. Thanks to time series observations with the KMTNet, orbits, optical sizes (and albedo), spin states and three dimensional shapes of asteroids and comets including NEOs will be systematically investigated and archived for the first time. Based on SDSS and BVRI colors, their approximate surface mineralogy will also be characterized. This so-called DEEP-South (Deep Ecliptic Patrol of the Southern Sky) project will provide a prompt solution to the demand from the scientific community to bridge the gaps in global sky coverage with a coordinated use of the network of ground-based telescopes in the southern hemisphere. We will soon finish implementing dedicated software subsystem consisted of automated observation scheduler and data pipeline for the sake of increased discovery rate, rapid follow-up, timely phase coverage, and efficient data analysis. We will give a brief introduction to test runs conducted at CTIO with the first KMTNet telescope in February and March 2015 and experimental data processing. Preliminary scientific results will also be presented.

  • PDF

Surface Treatment of Ge Grown Epitaxially on Si by Ex-Situ Annealing for Optical Computing by Ge Technology

  • Chen, Xiaochi;Huo, Yijie;Cho, Seongjae;Park, Byung-Gook;Harris, James S. Jr.
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.5
    • /
    • pp.331-337
    • /
    • 2014
  • Ge is becoming an increasingly popular semiconductor material with high Si compatibility for on-chip optical interconnect technology. For a better manifestation of the meritorious material properties of Ge, its surface treatment should be performed satisfactorily before the electronic and photonic components are fabricated. Ex-situ rapid thermal annealing (RTA) processes with different gases were carried out to examine the effects of the annealing gases on the thin-film quality of Ge grown epitaxially on Si substrates. The Ge-on-Si samples were prepared in different structures using the same equipment, reduced-pressure chemical vapor deposition (RPCVD), and the samples annealed in $N_2$, forming gas (FG), and $O_2$ were compared with the unannealed (deposited and only cleaned) samples to confirm the improvements in Ge quality. To evaluate the thin-film quality, room-temperature photoluminescence (PL) measurements were performed. Among the compared samples, the $O_2$-annealed samples showed the strongest PL signals, regardless of the sample structures, which shows that ex-situ RTA in the $O_2$ environment would be an effective technique for the surface treatment of Ge in fabricating Ge devices for optical computing systems.

Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans

  • Hwang, Hyeon-Shik;Lee, Kyung-Min;Uhm, Gi-Soo;Cho, Jin-Hyoung;McNamara, James A. Jr.
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.54-61
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effectiveness of the use of Reference Ear Plug (REP) during cone-beam computed tomography (CBCT) scan for the generation of lateral cephalograms from CBCT scan data. Methods: Two CBCT scans were obtained from 33 adults. One CBCT scan was acquired using conventional methods, and the other scan was acquired with the use of REP. Virtual lateral cephalograms created from each CBCT image were traced and compared with tracings of the real cephalograms obtained from the same subject. Results: CBCT scan with REP resulted in a smaller discrepancy between real and virtual cephalograms. In comparing the real and virtual cephalograms, no measurements significantly differed from real cephalogram values in case of CBCT scan with REP, whereas many measurements significantly differed in the case of CBCT scan without REP. Conclusion: Measurements from CBCT-generated cephalograms are more similar to those from real cephalograms when REP are used during CBCT scan. Thus, the use of REP is suggested during CBCT scan to generate accurate virtual cephalograms from CBCT scan data.

Design Optimization of a Type-I Heterojunction Tunneling Field-Effect Transistor (I-HTFET) for High Performance Logic Technology

  • Cho, Seong-Jae;Sun, Min-Chul;Kim, Ga-Ram;Kamins, Theodore I.;Park, Byung-Gook;Harris, James S. Jr.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • In this work, a tunneling field-effect transistor (TFET) based on heterojunctions of compound and Group IV semiconductors is introduced and simulated. TFETs based on either silicon or compound semiconductors have been intensively researched due to their merits of robustness against short channel effects (SCEs) and excellent subthreshold swing (SS) characteristics. However, silicon TFETs have the drawback of low on-current and compound ones are difficult to integrate with silicon CMOS circuits. In order to combine the high tunneling efficiency of narrow bandgap material TFETs and the high mobility of III-V TFETs, a Type-I heterojunction tunneling field-effect transistor (I-HTFET) adopting $Ge-Al_xGa_{1-x}As-Ge$ system has been optimized by simulation in terms of aluminum (Al) composition. To maximize device performance, we considered a nanowire structure, and it was shown that high performance (HP) logic technology can be achieved by the proposed device. The optimum Al composition turned out to be around 20% (x=0.2).

Development of an Nursing Assessment Tool for Emergency Patients (응급환자 간호사정 도구개발)

  • Ahn, Mi-Hyun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.2
    • /
    • pp.419-437
    • /
    • 1998
  • Nurses use a nursing process. that is a scientific approach method. in order to understand the clients' condition and to solve their problems. Professional nurses have accepted the nursing process as a standard framework for nursing activities, and the first step of the nursing process is nursing assessment. The purpose of this study was to develop a nursing assessment tool for emergency patients. Assessment is a first step in the nursing process, and scientific assessment helps to better understand the patients. Thus the development of an assessment tool for emergency patients will improve of nursing quality and advance to efficacy of emergency room(ER) management. The study involved the development of a conceptual framework, preliminary tool, content validity verification process. and reliability verification process. The conceptual framework was developed through a review of the literature. and preliminary tool was developed from the conceptual framework that based on care flow sheet' developed James A. Haley. The preliminary tool was evaluated for validity and reliability by seven experts, one ER nurse manager, two ER head nurses, two emergency medicine doctors. and two ER charge nurses and by ten nurses with one to five year careers in ER nursing. The results of this study was as follows 1. The conceptual framework which was developed was composed of three parts. They were triage criteria, first assessment and secondary assessment. 2. The preliminary tool which was developed had 31 items based on the conceptual framework. 3. To test expert validity a 4-point scale was used. items which had gained 3-4 points from six persons of the seven experts were selected. All 31 items from the preliminary tool were selected. 4. The reliability test was done by ten nurses educated in the use of the assessment tool. Two pairs of nurses simultaneously assessed the same patients. A total agreement percentile was calculated and result was 87.3% agreement. 5. After the validity and reliability testing. the final emergency patient nursing assessment tool was finalized with 31 items. and a check-list for the responses. This study concludes that the tool which was developed is both valid and reliable will advance quality care for emergency patients. This emergency nursing assessment tool was also found to be an adequate tool for assessment of emergency patients.

  • PDF

Pharmacophore Models of Paclitaxel- and Epothilone-Based Microtubule Stabilizing Agents

  • Lee, Sangbae;Lee, Yuno;Briggs, James M.;Lee, Keun Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.1972-1984
    • /
    • 2013
  • Microtubules play an important role in intracellular transport, mobility, and particularly mitosis. Paclitaxel (Taxol$^{TM}$) and paclitaxel-like compounds have been shown to be anti-tumor agents useful for various human tumors. Paclitaxel-like compounds operate by stabilizing microtubules through interface binding at the interface between two ${\beta}$-tubulin monomers in adjacent protofilaments. In this paper we present the elucidation of the structural features of paclitaxel and paclitaxel-like compounds (e.g., epothilones) with microtubule stabilizing activities, and relate their activities to spatial and chemical features of the molecules. CATALYST program was used to generate three-dimensional quantitative structure activity relationships (3D-QSARs) resulting in 3D pharmacophore models of epothilone- and paclitaxel-derivatives. Pharmacophore models were generated from diverse conformers of these compounds resulting in a high correlation between experimental and predicted biological activities (r = 0.83 and 0.91 for epothilone and paclitaxel derivatives, respectively). On the basis of biological activities of the training sets, five- and four-feature pharmacophore hypotheses were generated in the epothilone and paclitaxel series. The validation of generated hypotheses was achieved by using twelve epothilones and ten paclitaxels, respectively, which are not in the training sets. The clustering (grouping) and merging techniques were used in order to supplement spatial restrictions of each of hypothesis and to develop more comprehensive models. This approach may be of use in developing novel inhibitor candidates as well as contributing a better understanding of structural characters of many compounds useful as anticancer agents targeting microtubules.

Evaluation of crude protein, crude oil, total flavonoid, total polyphenol content and DPPH activity in the sprouts from a high oleic acid soybean cultivar

  • Mugisha, James;Asekova, Sovetgul;Kulkarni, Krishnanand P.;Park, Cheol Woo;Lee, Jeong-Dong
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.5
    • /
    • pp.723-733
    • /
    • 2016
  • Soybeans [Glycine max (L.) Merill] are a rich source of antioxidants and other phytonutrients. Soybean sprouts contain many biologically active secondary metabolites and are rich in polyphenols, flavonoids, and phenolic compounds. In the present study, two soybean cultivars, Hosim, with high oleic acid (- 80% in total seed oil), and Pungsannamul, with normal oleic acid (- 23%) in seed, were examined for changes in the content of crude protein, crude oil, total flavonoids, total phenolics, and DPPH (1,1-diphenyl-2-picryl-hydrazyl) during the sprouting duration of 5 days. The protein content in both the varieties was found to increase by the days of sprouting. The crude oil content of Pungsannamul sprouts was found to be maximum on day 1 (16.9%, w/w) and decreased thereafter to reach to the level of 14.8% on day 5. No significant differences in the crude oil content of Hosim sprouts from day 1 to 5 were observed. Flavonoid content was found to increase up to day 4 and then dropped on day 5, in both the cultivars. Total polyphenol content showed a tendency to increase up to day 3 and started to decrease significantly from day 4. DPPH activity was found to increase up to day 5 in both the varieties. All the components studied in the high oleic acid soybean sprouts showed a change in content during the sprouting process similar to the change that would occur in normal oleic acid soybeans. The study showed that the contents of antioxidant, flavonoid, and polyphenol significantly increase during the sprouting.

Tobacco-Related Chronic Illnesses: A Public Health Concern for Jamaica

  • Crawford, Tazhmoye V.;McGrowder, Donovan A.;Barnett, Jasper D.;McGaw, Barbara A.;McKenzie, Irving F.;James, Leslie G.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4733-4738
    • /
    • 2012
  • Background: Tobacco use is a leading cause of preventable morbidity and mortality from non-communicable diseases. The objectives of the study were to determine the percentage of annual income used to purchase tobacco-related products and treat tobacco-related illnesses, and assess the characteristics of smokers and their awareness of the health-related risks of smoking. Method: Stratified and snowball sampling methods were used to obtain information (via a 17-item, close-ended questionnaire) from 85 adult respondents (49 males and 36 females). The instrument comprised of demographic characteristics, smoking behavioural/lifestyle, health, and micro socio-economics. Results: There were no significant differences between individuals who were affected by chronic obstructive pulmonary disorder (COPD) (14.1%) and cardiovascular disease (18.8%). It was found that respondents spend 30-39% of their annual income on tobacco-related products. Forty percent (40.0%) and 41.7% of respondents with lung cancer and COPD respectively spend more than 50% of their annual income to treat these diseases. The majority (80%) of those who continues to consume tobacco-related products were uncertain as to why they were doing it. Not all the smokers were aware of the dangers of tobacco consumption despite their level of education. Conclusion: The majority of the respondents who had tobacco-related illnesses such as lung cancer and COPD spend a significant amount of their income on their health care. Not all the smokers were aware of the dangers of tobacco consumption despite their level of education. This suggests the need for increase public awareness where both smokers and non smokers are being fully or adequately informed about the dangers or health risks of tobacco consumption.

Characterization of machining quality attributes based on spindle probe, coordinate measuring machine, and surface roughness data

  • Tseng, Tzu-Liang Bill;Kwon, Yongjin James
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.2
    • /
    • pp.128-139
    • /
    • 2014
  • This study investigates the effects of machining parameters as they relate to the quality characteristics of machined features. Two most important quality characteristics are set as the dimensional accuracy and the surface roughness. Before any newly acquired machine tool is put to use for production, it is important to test the machine in a systematic way to find out how different parameter settings affect machining quality. The empirical verification was made by conducting a Design of Experiment (DOE) with 3 levels and 3 factors on a state-of-the-art Cincinnati Hawk Arrow 750 Vertical Machining Center (VMC). Data analysis revealed that the significant factor was the Hardness of the material and the significant interaction effect was the Hardness + Feed for dimensional accuracy, while the significant factor was Speed for surface roughness. Since the equally important thing is the capability of the instruments from which the quality characteristics are being measured, a comparison was made between the VMC touch probe readings and the measurements from a Mi-tutoyo coordinate measuring machine (CMM) on bore diameters. A machine mounted touch probe has gained a wide acceptance in recent years, as it is more suitable for the modern manufacturing environment. The data vindicated that the VMC touch probe has the capability that is suitable for the production environment. The test results can be incorporated in the process plan to help maintain the machining quality in the subsequent runs.