• Title/Summary/Keyword: Isolation Characteristic

Search Result 259, Processing Time 0.029 seconds

A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation (거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구)

  • Jeong, Dawoon;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.

Canonical correlation analysis based fault diagnosis method for structural monitoring sensor networks

  • Huang, Hai-Bin;Yi, Ting-Hua;Li, Hong-Nan
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.1031-1053
    • /
    • 2016
  • The health conditions of in-service civil infrastructures can be evaluated by employing structural health monitoring technology. A reliable health evaluation result depends heavily on the quality of the data collected from the structural monitoring sensor network. Hence, the problem of sensor fault diagnosis has gained considerable attention in recent years. In this paper, an innovative sensor fault diagnosis method that focuses on fault detection and isolation stages has been proposed. The dynamic or auto-regressive characteristic is firstly utilized to build a multivariable statistical model that measures the correlations of the currently collected structural responses and the future possible ones in combination with the canonical correlation analysis. Two different fault detection statistics are then defined based on the above multivariable statistical model for deciding whether a fault or failure occurred in the sensor network. After that, two corresponding fault isolation indices are deduced through the contribution analysis methodology to identify the faulty sensor. Case studies, using a benchmark structure developed for bridge health monitoring, are considered in the research and demonstrate the superiority of the new proposed sensor fault diagnosis method over the traditional principal component analysis-based and the dynamic principal component analysis-based methods.

Design of WCDMA Indoor Repeater Antenna for High Isolation using the Absorber based on Metamaterial Structure (메타구조 기반의 흡수체를 이용한 높은 격리도 특성의 WCDMA 댁내형 중계기 안테나 설계)

  • Kim, Hyoung-Jun;Yoon, Na-Nae;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.6
    • /
    • pp.57-62
    • /
    • 2012
  • In this paper, WCDMA indoor repeater antenna using an absorber based on metamaterial structure for high isolation is proposed. The proposed antenna consist of the main patch with the absorber based on metamaterial structure and parasitic patch. The WCDMA bandwidth is obtained by utilizing the coupling between the main and parasitic patches. The size of the absorber based on metamaterial structure is $13mm{\times}13mm$, the absorption is about 94 % at 2.18 GHz. The isolation characteristic of proposed WCDMA indoor repeater antenna between the service and donor antennas is improved by using a absorber based on metamaterial. The proposed WCDMA indoor repeater antenna has a gain higher than 6 dBi with a VSWR less than 2, and an isolation between the service and donor antennas greater than 85 dB over the WCDMA band from 1.92 GHz to 2.17 GHz. And size of the proposed antenna is $75mm{\times}75mm$.

The first virus isolation and partial characterization of equine herpesvirus-4 in a horse, South Korea

  • Choi, Eun-Jin;Lee, Hyun-Kyoung;Lee, Kyoung-Hyun;So, Byoung-Jae;Song, Jae-Young;Do, Jae-Chul;Yang, Seon-Joo;Lee, Hyun-Chul;Yang, Young-Jin
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.141-144
    • /
    • 2015
  • An equine herpesvirus-4 (EHV-4) was isolated in nasal swabs collected in a horse showing respiratory clinical signs. Equine dermis cells inoculated with the sample were observed with characteristic viral cytopathic effects after 3 days of postinoculation and the infected cells exhibited bright intracelluar fluorescence by indirect immunofluorescence assay. At the nucleotide level, the partial glycoprotein B gene of the Korean EHV-4 isolate (K001) had 99.9% identity to 1942 strain (GenBank No. M26171). To author's knowledge, the report describes the first isolation and partial characterization of EHV-4 in Korea. The virus can be used for further study of EHV-4.

Mechanical Characteristic Analysis of Coil Spring & Viscous Damper (Coil Spring & Viscous Damper System의 동특성분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.19-26
    • /
    • 2007
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.

Nonlinear dynamic analysis of a RC bridge subjected to seismic loading

  • Nanclares, German;Ambrosini, Daniel;Curadelli, Oscar;Domizio, Martin
    • Smart Structures and Systems
    • /
    • v.26 no.6
    • /
    • pp.765-779
    • /
    • 2020
  • Collapse of bridges in recent earthquakes demonstrates the need to deepen the understanding of the behaviour of these structures against seismic actions. This paper presents a highly detailed numerical model of an actual bridge subjected to extreme seismic action which results in its collapse. Normally, nonlinear numerical models have high difficulties to achieve convergence when reinforced concrete is intended to be represented. The main objective of this work is to determine the efficiency of different passive control strategies to prevent the structural collapse of an existing bridge. Metallic dampers and seismic isolation by decoupling the mass were evaluated. The response is evaluated not only in terms of reduction of displacements, but also in increasing of shear force and axial force in key elements, which can be a negative characteristic of the systems studied. It can be concluded that the use of a metallic damper significantly reduces the horizontal displacements and ensures the integrity of the structure from extreme seismic actions. Moreover, the isolation of the deck, which in principle seems to be the most effective solution to protect existing bridges, proves inadequate for the case analysed due to its dynamic characteristics and its particular geometry and an unpredictable type of axial pounding in the columns. This unexpected effect on the isolation system would have been impossible to identify with simplified models.

A Study on the Development of Gap filler Isolator by using the YIG Ferrite (YIG Ferrite를 이용한 Gap Filter용 아이솔레이터 개발에 관한 연구)

  • Jung, Seung-Woo;Choi, U-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.759-765
    • /
    • 2005
  • In this paper, developed isolator for gap filler is analyzed and designed using the simulation tool. Using the designed parameters, isolator is fabricated and tested in gap filler band. Temperature characteristics of isolator depend on magnet, YIG ferrite, and conductor etc. These require temperature stability and possible method of compensation for the temperature dependent effects. The temperature stabilization tries to use Ni-alloy. Developed isolator that compare with room temperature and high temperature characteristics has change fewer than 20 MHz. Implemented isolator shows more than 20 dB isolation characteristic at center frequency(2,650 MHz) and has 0.2 dB insertion loss in overall 100 MHz operating bandwidth. Return losses of input and output port are measured below -20 dB.

Design of hybrid ring directional coupler using lambda/8 section (Lambda/8 선로를 이용한 하이브리드 방향성 결합기의 설계)

  • Paek, Hyun;Choi, Jin-Kyu;Kim, Koon-Tae;Choi, Hyuk-Jae;Kwon, So-Hyun;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1593_1594
    • /
    • 2009
  • RFID system had used same frequency for transmit and receive signal. RFID recognize range is restrict, because of receive and transmit signal coupled each other. That cause directional coupler is not ideal isolation characteristic and antenna missmatching. So we proposed lambda/8 section directional coupler and design high isolation to use RFID.

  • PDF

A Novel application of Coupled Microstrip Directional filter (결합마이크로스트립 방향성여파기의 새로운 응용)

  • 장익수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.4
    • /
    • pp.33-38
    • /
    • 1985
  • By the complemental frequency characteristics of directional filter in passband and stopband the method of isolation between microwave RF and low frequency If is derived. And when this characteristic of microstrip directional filter is applied to MIC balanced mixer from 3.7 to 4.2 GHz, the experimental results of isolation and return loss are more than 20 65 in this band. This balanced mixer with the microstrip coupled directional filter is suitable for the DBS microwave receiver system.

  • PDF

Small-Sized High-Power PIN Diode Switch with Defected Ground Structure for Wireless Broadband Internet

  • Kim, Dong-Wook
    • ETRI Journal
    • /
    • v.28 no.1
    • /
    • pp.84-86
    • /
    • 2006
  • This letter presents a small-sized, high-power single-pole double-throw (SPDT) switch with defected ground structure (DGS) for wireless broadband Internet application. To reduce the circuit size by using a slow-wave characteristic, the DGS is used for the quarter-wave (${\lambda}$/4) transmission line of the switch. To secure a high degree of isolation, the switch with DGS is composed of shunt-connected PIN diodes. It shows an insertion loss of 0.8 dB, an isolation of 50 dB or more, and power capability of at least 50 W at 2.3 GHz. The switch shows very similar performance to the conventional shunt-type switch, but the circuit size is reduced by about 50% simply with the use of DGS patterns.

  • PDF