Abstract
In this paper, developed isolator for gap filler is analyzed and designed using the simulation tool. Using the designed parameters, isolator is fabricated and tested in gap filler band. Temperature characteristics of isolator depend on magnet, YIG ferrite, and conductor etc. These require temperature stability and possible method of compensation for the temperature dependent effects. The temperature stabilization tries to use Ni-alloy. Developed isolator that compare with room temperature and high temperature characteristics has change fewer than 20 MHz. Implemented isolator shows more than 20 dB isolation characteristic at center frequency(2,650 MHz) and has 0.2 dB insertion loss in overall 100 MHz operating bandwidth. Return losses of input and output port are measured below -20 dB.