• 제목/요약/키워드: Irradiation test

검색결과 680건 처리시간 0.027초

감마선을 이용한 Metronidazole이 함유된 Poly(vinyl alcohol) 하이드로겔 제조 및 특성 (Preparation and Characterization of Poly(vinyl alcohol) Hydrogel Contain Metronidazole by Irradiation)

  • 백재;박종석;정진오;정성인;권희정;안성준;임윤묵
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.21-27
    • /
    • 2016
  • Periodontitis is disease of damaged gum tissue that is not removed the plaque onto teeth. In case that the symptoms of disease get pain worse, it will have to extract tooth because of tumefy or bleeding at gums so treatment of drug was required to periodontitis. In this study, the hydrogel was prepared by including superior viscous, excellent elastic, and biocompatibility of Poly(vinyl alcohol, PVA) and antimicrobial drug of Metronidazole (MD). The 15 wt% PVA was dissolved in deionized water and then prepared PVA solution was irradiated using gamma-ray at 25 kGy ($10kGy\;hr^{-1}$). In addition, PVA hydrogel was immersed in each 0.1, 0.25 and 0.5 wt% MD solution using stirrer for 24 hr. The result of the gelation, 0.5 wt% MD loaded PVA hydrogel(76%) was lower than PVA hydrogel (88.2%). The swelling ration of 0.5 wt% MD loaded PVA hydrogel (294.8%) was higher than PVA hydrogel (105.2%). The compressive strength and thermal properties of MD loaded PVA hydrogel was gradually lower. The drug release test of 0.5 wt% MD loaded PVA hydrogel (61%) was higher than 0.1 wt% MD loaded PVA hydrogel (12%). Therefore, MD loaded PVA hygrogel may be a promising tool for periodontitis medicine by gamma-ray.

UV경화에 의한 폴리우레탄/유기화클레이 나노복합재료 제조와 물성 연구 (Preparation and Characterization of Polyurethane/Organoclay Nanocomposites by UV Curing)

  • 신금식;장영욱;김성우
    • 접착 및 계면
    • /
    • 제13권4호
    • /
    • pp.156-162
    • /
    • 2012
  • UV 경화형 우레탄아크릴레이트 수지와 유기화클레이를 혼합한 후 UV를 조사하여 경화시킴으로써 폴리우레탄-클레이 나노복합체를 제조하였다. 유기화클레이로서는 Closite20A (C20A) 및 이를 실란처리하여 표면에 아크릴기를 도입한 아크릴변성 C20A를 사용하였다. XRD와 TEM 분석으로부터 제조된 나노복합체는 삽입형 나노복합체이며, 아크릴 변성시킨 C20A가 변성시키지 않은 C20A에 비해 더 잘 분산되는 것을 알 수 있었다. DMTA, 연필경도분석, PET 필름에의 부착성 시험으로부터 클레이 첨가에 의해 유리전이온도와 저장탄성률 및 연필경도가 증가하고 PET 필름에의 부착성이 향상되며, 이러한 물리적 특성의 증가는 아크릴 변성시킨 C20A를 함유한 나노복합체에서 더 크게 발현됨을 알 수 있었다. 또한, 클레이 첨가에 의해 UV경화 시 수반되는 수축을 저하시킬 수 있음을 알았다. 한편, 제조된 나노복합체는 우수한 광투과도를 나타내었으나, 광택도는 나노입자를 함유하지 않은 경우에 비해 다소 저하되었다.

Solidification of high level waste using magnesium potassium phosphate compound

  • Vinokurov, Sergey E.;Kulikova, Svetlana A.;Myasoedov, Boris F.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.755-760
    • /
    • 2019
  • Compound samples based on the mineral-like magnesium potassium phosphate matrix $MgKPO_4{\times}6H_2O$ were synthesized by solidification of high level waste surrogate. Phase composition and structure of synthesized samples were studied by XRD and SEM methods. Compressive strength of the compounds is $12{\pm}3MPa$. Coefficient of thermal expansion of the samples in the range $250-550^{\circ}C$ is $(11.6{\pm}0.3){\times}10^{-6}1/^{\circ}C$, and coefficient of thermal conductivity in the range $20-500^{\circ}C$ is $0.5W/(m{\times}K)$. Differential leaching rate of elements from the compound, $g/(cm^2{\times}day)$: $Mg-6.7{\times}10^{-6}$, $K-3.0{\times}10^{-4}$, $P-1.2{\times}10^{-4}$, $^{137}Cs-4.6{\times}10^{-7}$; $^{90}Sr-9.6{\times}10^{-7}$; $^{239}Pu-3.7{\times}10^{-9}$, $^{241}Am-9.6{\times}10^{-10}$. Leaching mechanism of radionuclides from the samples at the first 1-2 weeks of the leaching test is determined by dissolution ($^{137}Cs$), wash off ($^{90}Sr$) or diffusion ($^{239}Pu$ and $^{241}Am$) from the compound surface, and when the tests continue to 90-91 days - by surface layer depletion of compound. Since the composition and physico-chemical properties of the compound after irradiation with an electron beam (absorbed dose of 1 MGy) are constant the radiation resistance of compound was established.

감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발 (The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system)

  • 송근영;황영관;이남호;육영호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.942-943
    • /
    • 2016
  • 스테레오 감마선 탐지장치는 감마선을 신호를 측정하여 위치값을 통한 2차원의 감마선 영상을 생성 한후, 가시광영상과 중첩하여 실제 공간상의 감마선 분포를 나타낸다. 스테레오 감마선 탐지장치는 감마선 탐지센서를 포함하는 탐지부와 감마선 신호를 검출하는 신호측정부 그리고 탐지부의 위치를 제어하기 위한 모션제어부로 구성된다. 본 논문에서는 개별적으로 구성된 각각의 모듈을 효율적으로 운용하기 위한 시스템 운용 알고리즘을 개발하였고, 이를 통해 감마선 조사시험장에서 감마선에 대한 영상화 및 분포정보 출력을 확인하였다.

  • PDF

감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구 (The study of collimator and radiation shield for the detection of the gamma-ray distribution)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.944-945
    • /
    • 2016
  • 감마선 영상화 장치에서 감마선을 탐지하는 검출부는 선원을 바라보는 Collimator와 Collimator 이외의 방향에서 입사되는 감마선을 차폐하기 위한 차폐체로 구성되며 검출센서는 해당 차폐체 내부에 위치하게 된다. 감마선에 대한 분포는 Collimator의 입사구를 통해 들어오는 신호와 검출부가 바라보는 방향에 대한 정보를 통해 분포를 나타낼 수 있다. 때문에 입사구에서 들어오는 신호 외에는 잡음으로 처리해야 하므로 차폐체의 역할이 중요하다. 본 논문에서는 상용 감마선 탐지장치의 보다 축소된 납 기반의 콜리메이터 및 차폐체에 대하여 구조와 물성을 변경하여 소형, 경량화 된 Collimator 및 차폐체를 제작하였다. 또한 감마선 조사시험시설을 이용하여 감마선 입사구의 측정된 신호값을 기준으로 차폐 효율을 분석하였다. 분석결과 제작된 Collimator 및 차폐체가 영상화 장치구현를 구현하는데 보다 효율적임을 확인하였다.

  • PDF

방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구 (Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging)

  • 송근영;황영관;이남호;나준희
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1535-1541
    • /
    • 2019
  • 방사선 사고 지역 및 제염이 필요한 지역에서의 안전하고 신속한 제염작업을 진행하기 위해서는 방사선 오염원에 대한 다양한 정보 획득이 필요하다. 특히 방사선원의 정확한 위치와 분포 정보의 파악은 신속한 후속 조치 및 오염원 제거를 위해 반드시 필요하며, 작업자의 방사선 피폭을 최소화할 수 있다. 방사선원의 위치와 분포 정보를 획득하기 위해서는 방사선 분포 탐지 장치를 사용한다. 방사선 분포 탐지 장치의 경우 일반적으로 탐지 센서 부가 단일 센서로 구성되며, 단일 센서의 물리적 한계로 인해 탐지 범위가 제한되는 문제점이 있다. 본 논문에서는 방사선 오염 분포 영상화 장치에 사용되는 단일 센서의 탐지 감도 제어를 위하여 보정 검출기를 적용하였으며, 이를 통해 제한적이었던 선량률 탐지 범위를 향상하였다. 또한 감마선 조사 시험을 통해 방사선 분포 탐지 범위의 개선을 확인하였다.

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

"Beach Lifeguards' Sun Exposure and Sun Protection in Spain"

  • de Troya Martin, Magdalena;Sanchez, Nuria Blazquez;Garcia Harana, Cristina;Leiva, Ma Carmen Alarcon;Arjona, Jose Aguilera;Ruiz, Francisco Rivas;de Galvez Aranda, Ma Victoria
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.244-248
    • /
    • 2021
  • Background: Sunburn is the main avoidable cause of skin cancer. Beach lifeguards spend many hours exposed to the effects of solar radiation during their work day, precisely at times of the year when levels of solar irradiation are highest. The aim of this study is to quantify the risk to beach lifeguards of sun exposure. Methods: A descriptive cross-sectional study was carried out in the Western Costa del Sol, southern Spain, during the summer of 2018. The research subjects were recruited during a skin cancer prevention course for beach lifeguards. All participants were invited to complete a questionnaire on their habits, attitudes, and knowledge related to sun exposure. In addition, ten were specially monitored using personal dosimeters for three consecutive days, and the results were recorded in a photoprotection diary. A descriptive analysis (mean and standard deviation for the quantitative variables) was performed, and inter-group differences were evaluated using the Mann-Whitney U test. Results: Two hundred fifteen lifeguards completed the questionnaire, and 109 met the criteria for inclusion in this analysis. The mean age was 23.8 years (SD: 5.1), 78.0% were male, 71.5% were phototype III or IV (Fitzpatrick's phototype), and 77.1% had experienced at least one painful sunburn during the previous summer. The mean daily personal ultraviolet exposure per day, the minimal erythema dose, and the standard erythema dose, in J/m2, were 634.7 [standard deviation (SD): 356.2], 2.5 (SD: 1.4) and 6.35 (SD: 3.6), respectively. Conclusion: Beach lifeguards receive very high doses of solar radiation during the work day and experience correspondingly high rates of sunburn. Intervention strategies to modify their sun exposure behavior and working environment are necessary to reduce the risk of skin cancer for these workers and to promote early diagnosis of the disease.

Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir

  • Choi, Yoomi;Kim, Hyoungtaek;Kim, Min Chae;Yu, Hyungjoon;Lee, Hyunseok;Lee, Jeong Tae;Lee, Hanjin;Kim, Young-su;Kim, Han Sung;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2599-2605
    • /
    • 2022
  • The Korea Retrospective Dosimetry network (KREDOS) performed an inter-laboratory comparison to confirm the harmonization and reliability of the results of retrospective dosimetry using mobile phone. The mobile phones were exposed to 192Ir while attached to the human phantoms in the field experiment, and the exposure doses read by each laboratory were compared. This paper describes the reference dosimetry performed to present the reference values for inter-comparison and to obtain additional information about the dose distribution. Reference dosimetry included both measurement using LiF:Mg,Cu,Si and calculation via MCNP simulation to allow a comparison of doses obtained with the two different methodologies. When irradiating the phones, LiF elements were attached to the phones and phantoms and irradiated at the same time. The comparison results for the front of the phantoms were in good agreement, with an average relative difference of about 10%, while an average of about 16% relative difference occurred for the back and side of the phantom. The differences were attributed to the different characteristics of the physical and simulated phantoms, such as anatomical structure and constituent materials. Nevertheless, there was about 4% of under-estimation compared to measurements in the overall linear fitting, indicating the calculations were well matched to the measurements.

Development of underwater 3D shape measurement system with improved radiation tolerance

  • Kim, Taewon;Choi, Youngsoo;Ko, Yun-ho
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1189-1198
    • /
    • 2021
  • When performing remote tasks using robots in nuclear power plants, a 3D shape measurement system is advantageous in improving the efficiency of remote operations by easily identifying the current state of the target object for example, size, shape, and distance information. Nuclear power plants have high-radiation and underwater environments therefore the electronic parts that comprise 3D shape measurement systems are prone to degradation and thus cannot be used for a long period of time. Also, given the refraction caused by a medium change in the underwater environment, optical design constraints and calibration methods for them are required. The present study proposed a method for developing an underwater 3D shape measurement system with improved radiation tolerance, which is composed of commercial electric parts and a stereo camera while being capable of easily and readily correcting underwater refraction. In an effort to improve its radiation tolerance, the number of parts that are exposed to a radiation environment was minimized to include only necessary components, such as a line beam laser, a motor to rotate the line beam laser, and a stereo camera. Given that a signal processing circuit and control circuit of the camera is susceptible to radiation, an image sensor and lens of the camera were separated from its main body to improve radiation tolerance. The prototype developed in the present study was made of commercial electric parts, and thus it was possible to improve the overall radiation tolerance at a relatively low cost. Also, it was easy to manufacture because there are few constraints for optical design.