• Title/Summary/Keyword: Iron oxide

Search Result 741, Processing Time 0.037 seconds

Effect of Carbon Dioxide in Dehydrogenation of Ethylbenzene to Styrene over Zeolite-Supported Iron Oxide Catalyst

  • 장종산;노제민;박상언;김우영;이철위
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.12
    • /
    • pp.1342-1346
    • /
    • 1998
  • The dehydrogenation of ethylbenzene with carbon dioxide has been carried out over ZSM-5 zeolite-supported iron oxide catalyst as well as commercial catalyst (K-Fe2O3) and unsupported iron oxide (Fe3O4) for comparison. In the dehydrogenation over the ZSM-5 zeolite-supported iron oxide catalyst, ethylbenzene is predominantly converted to styrene by an oxidative pathway in the presence of excess carbon dioxide. Carbon dioxide in this reaction is found to play a role as an oxidant for promoting catalytic activity as well as coke resistance of catalyst. On the other hand, both of commercial catalyst and unsupported Fe2O4 exhibit considerable decrease in catalytic activity under the same condition. It is suggested that an active phase for the dehydrogenation with carbon dioxide over ZSM-5 zeolite-supported iron oxide catalyst would be rather a reduced and isolated magnetite (Fe3O4)-like phase having oxygen deficiency in the zeolite matrix.

Microbial Reduction of Iron(III) Oxides: Implication for Permeable Reactive Barriers. (철환원 미생물을 이용한 3가 철의 환원에 관한 연구)

  • 임현정;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.250-253
    • /
    • 2002
  • Remediation of groundwater using zero valent iron filings has received considerable attention in recent years. However, zero valent iron is gradually transformed to iron(III) oxides at permeable reactive barriers, so the reduction of iron(III) oxides can enhance the longevity of the reactive barriers. In this study, microbial reduction of Fe(III) was performed in anaerobic condition. A medium contained nutrients similar to soil solution. The medium was autoclaved and deoxygenated by purging with 99.99% $N_2$ and pH was buffered to 6, while the temperature was regulated as 2$0^{\circ}C$. Activity of iron reducing bacteria were not affected by chlorinated organics but affected by iron(III) oxide. Although perchloroethylene(PCE) was not degraded with only ferric oxide, PCE was reduced to around 50% with ferric oxide and microorganism. It shows that reduced iron can dechlorinate PCE.

  • PDF

On the Crystalline Structures of Iron Oxides formed During Removal Process of Iron in Water (수중의 철 제거 시 생기는 산화철의 결정구조에 관한 연구)

  • Cho, Bong-Yeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1B
    • /
    • pp.107-111
    • /
    • 2006
  • The samples collected from two reactors are analyzed by X-ray diffraction and M$\ddot{o}$ssbauer spectroscopy in this study. It is concluded that the iron oxide crystal attached on anthracite media which possesses catalytic ability is identified to be Ferrihydrite, regardless of the value of pH from the analysis of the iron oxide. Iron oxide in Batch reactor is identified to be Microcrystalline goethite.

Preparation of iron oxide nanoparticle combined with radioisotope for molecular imaging

  • Park, Ji Yong;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.1
    • /
    • pp.36-42
    • /
    • 2018
  • Molecular imaging refers to detect the biochemical process in living organisms at the cellular and molecular levels and to quantify them. Due to several advantages of nanomaterials, various molecular images using nanomaterials are being tried. Attempts have been made to combine nanoparticles, known as micro- or nanosized nanomaterials, with radioactive isotopes for molecular imaging probe. The radiolabeled nanoparticles will expend the molecular imaging due to nanoparticle's size-dependent nature. In particular, iron oxide nanoparticles can be used for magnetic resonance imaging, can be adjusted in size, easily functionalized, and biocompatible, making it a very good platform for molecular imaging. In addition, iron oxide nanoparticles may be the best example for a new approach to molecular imaging techniques. In this paper, we introduce various methods for preparation of iron oxide nanoparticle combined with radioisotope starting from various synthesis methods of iron oxide nanoparticles to utilize iron oxide nanoparticles as a platform for molecular imaging through radioactive labeling.

Development of DNA Sensor Using Magnetic Iron Oxide Nanoparticle (자성 산화철(iron oxide) 나노입자를 이용한 DNA 센서 개발)

  • Nam, Ki-Chang;Song, Kwang-Soup
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.51-56
    • /
    • 2011
  • The surface of magnetic iron oxide nanoparticles (${\gamma}-Fe_2O_3$) is functionalized ($-NH_2$, -COOH) with bifunctional organic molecules and evaluated using FT-IR (Fourier transform infrared spectroscopy). We immobilize 21-base pair probe DNA and hybridize fluorescence-labeled (Cy5) target DNA onto the functionalized iron oxide nanoparticles. The fluorescence images obtained from a confocal microscopy show that the functionalized iron oxide nanoparticles should detect the hybridization of complementary and noncomplementary DNA.

Large-scale Synthesis of Uniform-sized Nanoparticles for Multifunctional Medical Applications

  • Hyeon, Taeg-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.1-1
    • /
    • 2011
  • We developed a new generalized synthetic procedure, called as "heat-up process," to produce uniform-sized nanocrystals of many transition metals and oxides without a size selection process. We were able to synthesize uniform magnetite nanocrystals as much as 1 kilogram-scale from the thermolysis of Fe-oleate complex. Clever combination of different nanoscale materials will lead to the development of multifunctional nano-biomedical platforms for simultaneous targeted delivery, fast diagnosis, and efficient therapy. In this presentation, I would like to present some of our group's recent results on the designed fabrication of multifunctional nanostructured materials based on uniform-sized magnetite nanoparticles and their medical applications. Uniform ultrasmall iron oxide nanoparticles of <3 nm were synthesized by thermal decomposition of iron-oleate complex in the presence of oleyl alcohol. These ultrasmall iron oxide nanoparticles exhibited good T1 contrast effect. In in vivo T1 weighted blood pool magnetic resonance imaging (MRI), iron oxide nanoparticles showed longer circulation time than commercial gadolinium complex, enabling high resolution imaging. We used 80 nm-sized ferrimagnetic iron oxide nanocrystals for T2 MRI contrast agent for tracking transplanted pancreatic islet cells and single-cell MR imaging. We reported on the fabrication of monodisperse magnetite nanoparticles immobilized with uniform pore-sized mesoporous silica spheres for simultaneous MRI, fluorescence imaging, and drug delivery. We synthesized hollow magnetite nanocapsules and used them for both the MRI contrast agent and magnetic guided drug delivery vehicle.

  • PDF

Experimental Simulation of Iron Oxide Formation on Low Alloy Steel Evaporator Tubes for Power Plant in the Presence of Iron Ions

  • Choi, Mi-Hwa;Rhee, Choong-Kyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2577-2583
    • /
    • 2009
  • Presented are the formation of iron oxide layers on evaporator tubes in an actual fossil power plant operated under all volatile treatment (AVT) condition and an experimental simulation of iron oxide formation in the presence of ferrous and ferric ions. After actual operations for 12781 and 36326 hr in the power plant, two iron oxide layers of magnetite on the evaporator tubes were found: a continuous inner layer and a porous outer layer. The experimental simulation (i.e., artificial corrosion in the presence of ferrous and ferric ions at 100 ppm level for 100 hr) reveals that ferrous ions turn the continuous inner oxide layer on tube metal to cracks and pores, while ferric ions facilitate the production of porous outer oxide layer consisting of large crystallites. Based on a comparison of the oxide layers produced in the experimental simulation with those observed on the actually used tubes, we propose possible routes for oxid layer formation schematically. In addition, the limits of the proposed corrosion routes are discussed in detail.

Effect of FeOOH on Burn Rate for AP Propellant (AP계 추진제에서 황색산화철의 연소촉매 효과)

  • Yim, Yoo-Jin;Kim, Jun-Hyung;Yoo, Ji-Chang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.390-393
    • /
    • 2010
  • The thermal decomposition rate of ammonium perchlorate with 3% of yellow iron oxide, FeOOH was found to be much faster than with red iron oxide, $Fe_2O_3$. By applying yellow and red iron oxide as a burning rate modifier to HTPB/AP propellant, burning rate of the HTPB/AP propellant with yellow iron oxide was shown to be 10 ~ 25% faster than with red iron oxide. There was no special difference in viscosity and hardness buildup of yellow and red oxide added HTPB/AP formulations.

  • PDF

Preparation of Anodic Iron Oxide Composite Incorporated with WO3 on the Stainless Steel Type-304 Substrate Through a Single-step Anodization (단일공정 양극산화를 이용한 WO3가 복합된 304 스테인레스 강 산화 피막 제조)

  • Kim, Moonsu;Lee, Jaewon;Lee, Kiyoung;Kim, Yong-Tae;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.5
    • /
    • pp.257-264
    • /
    • 2020
  • Anodization of Fe and Fe alloys is one of the most promising techniques to obtain iron oxide films applying to the various electrochemical devices due to their electrochemical catalytic properties. In this study, we investigate on the preparation of anodic iron oxide composite incorporated with WO3 through a single-step anodization of stainless steel type-304 (STS304) as a substrate. The effects of applied voltage and tungsten precursor on the structural characteristics of iron oxide composite with different amount of incorporated WO3 were observed. It is demonstrated that when the voltage of 60 V applied with 20 mM of Na2WO4 as a precursor, anodic iron oxide composite with a large pore diameter and a thick oxide length in which WO3 is uniformly incorporated is obtained.

Evaluation Method of Cosmetics for the Effect of Fine Dust Adhesion Prevention Using Floating Chamber (부유챔버를 이용한 화장품의 미세먼지 부착방지 효과 평가법)

  • Kim, Woncheol;Kim, Han Jo;Boo, Yong Chool;Koh, Jae Sook;Baek, Ji Hwoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.4
    • /
    • pp.319-327
    • /
    • 2020
  • Particulate matters (PM) are small particulate pollution that decrease the function of skin barrier, which causes inflammatory skin diseases and extrinsic aging. In this study, we evaluated the effect of preventing the adherence of PMs from several cosmetic products applied to human skin using iron oxide black. The PM floating chamber consists of skin exposure area, PM inlet, floating power device, and an outlet so that PM can be naturally attached to the skin while floating in the chamber. The change in skin brightness according to the floating concentration of alternative fine dust was checked to confirm the optimal floating concentration conditions. The intensity difference (before-after intensity, Δ) before and after adhesion of iron oxide black was proportional to the amount of PM adhered. The anti-adherence effect of iron oxide black on five cosmetic products were evaluated through 20 each subjects by comparing the amount of iron oxide black adhered on the control and treatment. The difference in brightness before and after the iron oxide black attached to the skin was calculated and compared with the control group(p < 0.05). When over 150 mg of iron oxide black was adhered on the skin, the interference of intensity was low and clearly showed the skin adhered pattern. According to the application of the five cosmetics, the intensity difference was significantly lower than the control group. This means that depending on the product, it prevented the attachment of iron oxide black. This study is a safe and useful method to confirm the prevention of PM skin adherence. In conclusion, cosmetics can prevent the adherence of PM on the skin according to the formulation or ingredients characteristics.