• 제목/요약/키워드: Ionization energy

검색결과 394건 처리시간 0.026초

Examination of the Fragmentation Behavior of Hemin and Bilin Tetrapyrroles by Electrospray Ionization and Collision-induced Dissociation

  • Sekera, Emily R.;Wood, Troy D.
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.91-94
    • /
    • 2018
  • Bilin tetrapyrroles are metabolic products of the breakdown of porphyrins within a species. In the case of mammals, these bilins are formed by the catabolism of heme and can be utilized as either biomarkers in disease or as an indicator of human waste contamination. Although a small subset of bilin tandem mass spectrometry reports exist, limited data is available in online databases for their fragmentation. The use of fragmentation data is important for metabolomics analyses to determine the identity of compounds detected within a sample. Therefore, in this study, the fragmentation of bilins generated by positive ion mode electrospray ionization is examined by collision-induced dissociation (CID) as a function of collision energy on an FT-ICR MS. The use of the FT-ICR MS allows for high mass accuracy measurements, and thus the formulas of resultant product ions can be ascertained. Based on our observations, fragmentation behavior for hemin, biliverdin and its dimethyl ester, phycocyanobilin, bilirubin, bilirubin conjugate, mesobilirubin, urobilin, and stercobilin are discussed in the context of the molecular structure and collision energy. This report provides insight into the identification of structures within this class of molecules for untargeted analyses.

A Correction Method for the Peak Tailing Backgrounds for Accurate Isotope Ratio Measurements of Uranium in Ultra Trace Levels using Thermal Ionization Mass Spectrometry

  • Park, Jong-Ho;Choi, In-Hee;Park, Su-Jin;Lee, Myung-Ho;Song, Kyu-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4327-4331
    • /
    • 2011
  • A new method in thermal ionization mass spectrometry (TIMS) was developed to correct peak tailing backgrounds in the isotope ratio measurements of uranium in ultra trace levels for higher accuracy. Two different uranium standard reference materials (U005 and U030) were used to construct databases of signal intensities at mass 234 u and mass 236 u, which correspond to the two uranium minor isotopes, and signal intensity of $^{238}U$. Correlations between peak tailing backgrounds and $^{238}U$ were obtained by least-squares regression on calculated backgrounds at mass 234 u and mass 236 u with respect to the signal intensity of $^{238}U$ followed by separation of the peak tails of the two major isotopes of uranium ($^{235}U$ and $^{238}U$), which enables us to obtain a master equation for peak tailing background correction on all kinds of samples. Verification of the correction method was carried out using U010 and IRMM-040a.

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

표준 감마선 전리함 장치에 의한 방사능 비교 측정 (Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System)

  • 박태순;우동호;오필제;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.11-18
    • /
    • 1984
  • Well type 전리함과 미세전류 측정희로를 사용하여 표준 감마선 전리함 장치를 개발하였다. 미세전류는 automatic Townsend balance with stepwise compensation방법을 사용하여 측정하였다. $^{226}Ra$을 기준 선원으로 택하여 감마 방출핵종인 $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs^{22}Na$에 대한 비교 교정인자를 산출하였으며, 감마에너지의 함수로서 검출 효율 곡선을 구하였다.

  • PDF

Visible Surface-Assisted Laser Desorption/Ionization Mass Spectrometry of Small Macromolecules Deposited on the Graphite Plate

  • Kim, Jung-Hwan;Paek, Kyung-Soo;Kang, Wee-Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.315-319
    • /
    • 2002
  • Visible surface-assisted desorption/ionization mass spectrometry (SALDI-MS) has been investigated for several small macromolecules deposited on the graphite plate using laser radiation at 532 nm where most of the macromolecules are transparent. The graphite surface functioned well as a photon absorbing material and an energy transfer mediator for visible light. The results show that visible SALDI is a much softer ionization technique than UV-MALDI and FAB-MS in our results with synthetic macromolecules, PPG, PPGMBE and cavitand molecules. For the SALDI of biomolecules, glycerol as a proton source was essential with the graphite plate. As in visible SALDI, the role division of the photon absorbing material and the cationization agent can provide a generality in mass spectrometric analysis of macromolecules compared with MALDI using the dual functional matrix.

Application of Chemical Ionization Mass Spectrometry to Heterogeneous Reactions of OH with Aerosols of Tropospheric Interest

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2017
  • Studies performed on heterogeneous reactions of hydroxyl radicals (OH) in aerosol materials of tropospheric interest are presented, focusing on the chemical ionization mass spectrometric approach. Kinetic investigations of these reactions reduced deviation in the estimation of OH concentration in the troposphere by atmospheric modeling from field measurements. Recently, OH uptake was investigated under wet conditions to acquire kinetic information under more realistic conditions representative of the troposphere. The information on the mechanism and kinetics of OH uptake by tropospheric aerosol materials will contribute to the updating of atmospheric models, allowing a better understanding of the troposphere.

변형 힘을 받는 p형 $Si_{1-x}Ge_x$의 이동도 연구 (Study of the Mobility for Strained p-type $Si_{1-x}Ge_x$ Alloys)

  • 전상국
    • 한국전기전자재료학회논문지
    • /
    • 제11권3호
    • /
    • pp.181-187
    • /
    • 1998
  • The ionization energy and degree of ionization for p-type $Si_{1-x}Ge_x$ with boron doping are calculated taking into account the screening and broadening effects. The drift and Hall mobilities are then calculated using the relaxation time approximation and compared with the previously reported measurement data for relaxed and strained $Si_{1-x}Ge_x$ alloys to estimate the alloy scattering potential. From a fit, the alloy scattering potential is found to be 0.5 eV. The in-plane drift mobility for p-type strained $Si_{1-x}Ge_x$ grown on (001) Si substrate is approximately 1+$10x^2$ times higher than that for bulk Si in the high doping range.

  • PDF

Feasibility of Using Graphite Powder to Enhance Uranium Ion Intensity in Thermal Ionization Mass Spectrometry (TIMS)

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • 제7권4호
    • /
    • pp.102-105
    • /
    • 2016
  • This study explored the feasibility of using a carburization technique to enhance the ion intensity of isotopic analysis of ultra-trace levels of uranium using thermal ionization mass spectrometry (TIMS). Prior to fixing uranium samples on TIMS filaments, graphite powder suspended in nitric acid was deposited on rhenium filaments. We observed an enhancement of $^{238}U^+$ intensity by a factor of two when carburization was used, and were able to roughly optimize the amount of graphite powder necessary for carburization. The positive shift in heating current when evaporating filaments upon carburization implies that uranium was chemically altered by carburization, when compared to normal fixation processes. The good agreement between our method and known standards down to an ultra-trace level shows that the proposed technique can be applied to isotopic uranium analysis down to abundances of ~10 pg.

고온전자의 충돌 이온화 및 게이트 산화막 주입 모델링을 위한 Tail 전자 Hydrodynamic 모델 (Tail Electron Hydrodynamic Model for Consisten Modeling of Impact Ionization and Injection into Gate Oxide by Hot Electrons)

  • 안재경;박영준;민홍식
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.100-109
    • /
    • 1995
  • A new Hydrodynamic model for the high energy tail electrons(Tail Electron Hydrodynamic Model : TEHD) is developed using the moment method. The Monte Carlo method is applied to a $n^{+}-n^{-}-n^{+}$ device to calibrate the TEHD equations. the discretization method and numerical procedures are explained. New models for the impact ionization and injection into the gate oxide using the tail electron density are proposed. The simulated results of the impact ionization rate for a $n^{+}-n^{-}-n^{+}$ device and MOSFET devices, and the gate injection experiment are shown to give good agreement with the Monte Carlo simulation and the measurements.

  • PDF

The Propagation of Cosmic Ray in Protoplanetary Disks

  • Roh, Soonyoung;Fujii, Yuri I.;Inutsuka, Shu-ichiro;Suzuki, Takeru;Momose, Munetake
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.72.4-73
    • /
    • 2016
  • For the development of magneto rotational instability, which drives mass accretion in protoplanetary disks, sufficient ionization degree is needed. Cosmic rays are believed to be one of the dominant ionization sources for protoplanetary disk gas. In previous studies, ionization rates are computed by considering the effect of attenuation of the cosmic ray (CR) intensity as a function of column density in an unmagnetized cloud. However, in reality particles should sweep up larger column density to reach at the midplane of disk due to their gyromotion. In this study, we investigate the propagation of CR protons in a protoplanetary disk by solving transport and energy loss equations. We discuss the change in CR intensity due to magnetic field in a protoplanetary disk.

  • PDF