• Title/Summary/Keyword: Ionization development

Search Result 187, Processing Time 0.028 seconds

Rationale and Definition of The Criteria of The Efficiency of The Biological Activity of Optical Radiation on Animal Organism.

  • Chervinsky, Leonid S.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2018
  • In today's technological development of human society more and more influence on the lives of biological organisms different electromagnetic radiation. Therefore, the study and analysis of the mechanisms of their effects is an urgent task. The purpose of research - the study of the primary mechanisms of interaction of photons of optical radiation with the structures of biological objects, using the laws of quantum mechanics and biophysics. Photobiological basis of the mechanism of action of EMR optical range is the energy absorption of light quanta (photons) by atoms and molecules of biological structures (law Grotgus-Draper), which resulted in the formation of electronically excited states of these molecules with the transfer of photon energy (internal photoeffect). This is accompanied by electrolytic dissociation and ionization of biological molecules. The degree of manifestation of photobiological effects in the body depends on the intensity of the optical radiation, which is inversely proportional to the square of the distance from the source to the irradiated surface. Accordingly, in practice, determine not the intensity and irradiation dose at a certain distance from the source of exposure by the exposure time.

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

  • Kang, Ji Hwan;Kim, Yong Doo;Lee, Jinhong;Lee, Sangil
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.202-211
    • /
    • 2021
  • Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

A Noise Reduction Technique for Enhancing Pituitary Adenoma Diagnostic on Magnetic Resonance Image (개선된 뇌하수체 선종 진단을 위한 자기공명영상 노이즈 제거 기법)

  • Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.285-290
    • /
    • 2019
  • Magnetic resonance imaging is a technique specialized in soft tissue imaging with high contrast resolution without in vivo ionization and has been widely used in various clinical settings. In particular, the recent increase in social stress factors has been used in the diagnosis of pituitary adenoma, the incidence increases rapidly. Recently, due to the development of magnetic resonance imaging, it is possible to diagnose micro pituitary adenoma, but despite the use of contrast medium, there has been a difficulty in diagnosing the pituitary adenoma due to its small size and noise. In order to solve this problem, a proposed method of separating signal components image and noise components image from a measured image is applied, and the improvement of diagnostic efficiency is attempted by removing noise. As a result, it was confirmed that the image quality was improved as a whole by applying SNR for 30 subjects data. It is expected that this study will be useful as a pre-processing method for improving the image quality and developing diagnostic indicators of pituitary adenoma.

Comparison of Matrices for Optimal Analysis of Synthetic Polymers Using MALDI-TOF Mass Spectrometry

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Choi, Yoon-Ji;Choi, Jung Hoon;Park, Moonhee;Shin, DongJin;Oh, YoonSeok;Kim, YangSun;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.77-81
    • /
    • 2020
  • Characterization of the various chemical aspects of composite polymers is important for quality control of manufactured polymers. In this study, we compared three suitable matrices (α cyano-4-hydroxycinnamic acid [CHCA], 2,5 dihydroxy benzoic acid [2,5-DHB], and dithranol), to characterize various synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Although the spectra obtained with the CHCA and 2,5-DHB matrices were generally good, in certain samples ghost peaks disappeared only when dithranol was used as the matrix. Furthermore, we examined the use of sodium trifluoroacetate (NaTFA) as an additive to reduce interference by metals and copolymers in the spectra. In conclusion, appropriate selection of a matrix, according to the characteristics of the polymer, and the use of additives to improve sensitivity are important considerations for polymer analysis and development.

Investigating the Potential of Lipids for Use as Biomarkers for Glioblastoma via an Untargeted Lipidomics Approach

  • Burcak Soylemez;Zekeriya Bulut;Serap Sahin-Bolukbasi
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.133-143
    • /
    • 2023
  • Objective : The types and functions of lipids involved in glioblastoma (GB) are not well known. Lipidomics is a new field that examines cellular lipids on a large scale and novel aplication of lipidomics in the biomedical sciences have emerged. This study aimed to investigate the potential of blood lipids for use as biomarkers for the diagnosis of GB via untargated lipidomic approach. Gaining a deeper understanding of lipid metabolism in patients with GB can contribute to the early diagnosis with GB patiens and also development of novel and better therapeutic options. Methods : This study was performed using blood samples collected from 14 patients (eight females and six males) and 14 controls (eight females and six males). Lipids were extracted from blood samples and quantified using phosphorus assay. Lipid profiles of between patients with GB and controls were compared via an untargeted lipidomics approach using 6530 Accurate-Mass Q-TOF LC/MS mass spectrometer. Results : According to the results obtained using the untargeted lipidomics approach, differentially regulated lipid species, including fatty acid (FA), glycerolipid (GL), glycerophospholipid (PG), saccharolipid (SL), sphingolipid (SP), and sterol lipid (ST) were identified between in patients with GB and controls. Conclusion : Differentially regulated lipids were identified in patients with GB, and these lipid species were predicted as potential biomarkers for diagnosis of GB.

A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development (II) - Double ionization of the K-shell in $^{125}I$- (다목적 동시측정 장치 개발에 의한 원자핵 구조 연구 (II) - $^{125}I$ 붕괴시 K 각 이중 이온화 현상 -)

  • Chung, Won-Mo;Chung, Kap-Soo;Joo, Koan-Sik;Nam, Kie-Yong;Choi, Hey-Jin;Jeon, Woo-Ju;Na, Sang-Kyun;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • Double ionization of the K- shell accompanying K- shell electron capture of the 0.035 MeV transition of $^{125}I$ has been studied by counting coincidences between $K_{\alpha}$ hypersatellite X-rays and Ka satellite X-rays emitted when double vacancies are filled. The $^{125}I\;and\;^{125}Te^m$ source materials were used in the measurement. We obtained the coincidence spectrum using two NaI(T1) detectors and a Ge(Li) detector and TAC(Time-to-Amplitude Converter), and then analysed the measured coincidence number $N(K_{\alpha}^{II},\;K_{\alpha}^s)$, the total number $N(K_{\alpha})$ of K X-ray. The probability per K-shell electron capture that a double vacancy is formed, $P_{KK}$ is formed, $P_{KK}$ is found to be $2.15{\times}10^{-4}$.

  • PDF

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.