• Title/Summary/Keyword: Ion selective membrane

Search Result 204, Processing Time 0.028 seconds

Silicone Rubber Membrane-Based Chloride Ion-Selective Electrode (실리콘러버-지지체 염화이온선택성 막전극)

  • Sakong, Dong-Sik;Kim, Jin-Mog;Cha, Jin-Mog
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.12
    • /
    • pp.653-660
    • /
    • 1997
  • Silicone rubber-matrix membranes doped with tetradecyltrimethylammonium chloride (TDTMACl) are used to enhance electrode performance for chloride measurements in physiological samples. The optimized membrane formulation incorporates 95.4 wt% silicone rubber and 4.6 wt% TDTMACl, and its pH response is negligible in the range of pH 6-10. The TDTMACl-doped silicone rubber membrane exhibits sub-Nernstian response to chloride from 10 to 300 mM (-37.5 mV/decade), but its selectivities for chloride over other anions are remarkably enhanced: KpotCl,NO3=1.3, KpotCl,I=2.0, KpotCl,Sal=0.8, KpotCl,SCN=2.0 and KpotCl,ClO4=0.8. Furthermore, since the silicone rubber-matrix membrane exhibits better adhesion to the solid surface than do PVC membranes, the lifetime of the coated-wire type membrane electrode is greatly improved. The response properties toward chloride and salicylate for solid-state sensor are not significantly changed after at least 35 days of use.

  • PDF

Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes (용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정)

  • Kang, Tae Young;Kim, Sung Bae;Oh, Hyon Joon;Han, Sang Hyun;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • The complex formation constants (${\beta}_{MLn}$) of potassium and various sodium-selective neutral carriers in solvent polymeric membranes have been determined using solvent polymeric membrane-based optodes and ion-selective electrodes (ISEs). Two different types of PVC-based membranes containing the H^+selective chromoionophore (ETH 5294) with and without a sodium ionophore (4-tert-bntylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecylmethylmalonate or monensin methyl ester) were prepared and their optical responses to either the changes in alkali metal cation (e.g., sodium and potassium) concentrations at a fixed pH (0.05 M Tris-HCl, pH 7.2) or varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The same type of membranes were also mounted in conventional electrode body and their potentiometric responses to varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The complex formation constants of the ligand could be calculated from the calibration plots of the relative absorbance vs. the activity ratios of cation and proton ($a_{M^+}/a_{H^+}$) and of the emf vs. pH. It was confirmed that the ratio values of the complex formation constants for the primary and interfering ions are closely related to the experimental selectivity coefficients of ISEs.

  • PDF

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

Effect of Ultrasonic Pretreatment on Analysis of Potassium Ion in Human Urine Using 15-Crown-5-Anthracene-based Membrane (15-Crown-5-Anthracene 막을 이용한 요 중의 칼륨이온 분석에 미치는 초음파 전처리의 효과)

  • Lee, Ji-Young;Chang, Hye-Young;Bae, Zun-Ung
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.1
    • /
    • pp.13-18
    • /
    • 2003
  • The effect of ultrasonic decomposition was introduced to develop a pretreatment method for the analysis of potassium ion in human urine by potentiometry. N-(4’-benzo-15-crown-5)-anthracene-9-imine, which has a good selectivity coefficient for potassium against ammonium, was used as an ion-selective material for the determination of potassium in urine with relatively high concentration of $NH_4{^+}$. Protenis in urine be removed by 85.1% when the sample acidified with 1.0 M $HNO_3$ was preteated for 100 s by sonication. Potential response of the membrane electrode in the pretreated urine had a slope of 54.6(${\pm}0.2,\;n=5$) mV/decade over the linear range of log $[K^+]$=-5~-1(r=0.9997). When an oxidant, $H_2O_2$, was addwd to the urine sonicated with $HNO_3$, the deproteinization increased 10% more than that in case if only $HNO_3$ and then the maximum ratio of ca. 95% was obtained. Moreover, the Nernstian slope for $K^+$ added to the urinary sample increased to 56.7(${\pm}0.1,\;n=3$) mV/decade. When the calibration curves were measured, the slopes did not vary even after the electrode was successively used 20 times with ultrasonic cleaning. The results showed that an ultrasonic pretreatment method provides simplicity in use, reduced treatment time and improved potentiometric characteristics of the membrane as the method effectively removes ca. 95% of proteins in urine.

Fabrication of Low-cost and Flexible Potassium Ion Sensors based on Screen Printing and Their Electrochemical Characteristics (스크린 프린팅 기반 저가형의 플렉서블 칼륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Son, Seon Gyu;Park, Hong Jun;Kim, Yeong Kyun;Cho, Hyeon-Sang;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.737-741
    • /
    • 2019
  • A low-cost and flexible potassium ion (K+) sensor was fabricated through a screen-printed process. Uniform and conformal coating of conductive inks was verified by scanning electron microscopy and optical microscopy measurements. The K+-sensors showed a high sensitivity, fast response time, and low detection limit. The sensitivity of K+-sensor was similar to that of both mechanically normal and bent states. The K+-sensor exhibited a good reproducibility with no hysteresis effect and excellent long term stability. In addition, the K+-sensor showed an excellent selectivity for K+ concentrations in the presence of other interfering cation ions. Successful measurements of K+ concentrations in sports drink samples were demonstrated by comparing K+ concentration values from K+-sensor to those of using a commercial K+-meter.

Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier (중성운반체를 이용한 리튬이온 선택 전극)

  • Kim, Jae Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.33-39
    • /
    • 1992
  • THF-based crown-4 of 16-membered rings having tetrahydrofuran unit was synthesized by an acid-catalyzed condensation of furan and acetone followed by hydrogenation in an effort to obtain highly elective ionophores for lithium ions. The new ionophore was compared with previously reported ionophores under similar measurement conditions with the same plasticizer, tris(2-ethylhexyl) phosphate in poly(vinyl chloride)(PVC) membrane electrodes. Separate solution method was used to determine relative selectivity coefficients for the electrode. The selectivity coefficients($K_{LiM}^{POT}$) of lithium over ammonium, alkali and alkaline earth metal ions go from about $2.4{\times}10^{-1}$ to $2.3{\times}10^{-4}$ to working range and pH dependence have also been studied.

  • PDF

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.

Binding Set Analysis for Interaction of Human Serum Albumin with Cethyl Trimethylammonium Bromide

  • Bordbar, Abdol-Khalegh;Sohrabi, Nasrin;Gharibi, Hossain
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.791-795
    • /
    • 2004
  • The binding of cethyl trimethylammonium bromide, (CTAB) with human serum albumin (HSA) has been investigated at 5 mM phosphate buffer pH 7.0, 27 $^{\circ}C$ and various ionic strength using ion selective membrane electrodes. This method is faster and much more accurate than equilibrium dialysis technique, so provides sufficient and accurate data for binding data analysis. A novel and simple method was introduced for resolution and characterization of binding sets on basis of binding capacity concept. The values of Hill binding parameters were estimated for each set and used for calculation of intrinsic binding affinity. The results interpreted on basis of nature of forces which interfered in the interaction and represent the existence of three and two binding sets for binding of CTAB at $10^{-4}$ and $10^{-3}$ M of NaBr, respectively.

The biofuel cell: development of new materials for composing electron mediator-free and electrochemical active bacteria-free biofuel cell

  • Park Doohyun;Park Yongkeun;Kim Sikyun;Lee Daesik;Shin Inho
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.92-99
    • /
    • 2000
  • In this study biofuel cell is classified into 5 generation fuel cell system based on structural and structural difference. I optionally named the biofuel cell with electron mediators prototype, that with electrochemical active bacterium 2nd generation, that with modified electrode with NR 3rd generation, that with catalytic active electrode 4th generation, and that using air as a catholyte instead of ion selective membrane and cathode, respectively. The electricity production was compared among 5 types biofuel cell and was confirmed to be $50-100\%$ higher in 4th and 5th generation than in 1st to 3rd generation.

  • PDF

Acyclic Vanilloid Receptor Antagonist Based on Capsazepine

  • Park, Hyeung-Geun;Park, Mi-Kyoung;Choi, Ji-Yeon;Choi, Se-Hoon;Lee, Ji-Hye;Suh, Young-Ger;Oh, Uh-Taek;Kim, Hee-Doo;Lee, Jee-Woo;Park, Young-Ho;Jeong, Yeon-Su;Choi, Jin-Kyu;Jew, Sang-Sup
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.349.1-349.1
    • /
    • 2002
  • Capsaicin. the pungent component of chili pepper. opens a novel cation selective ion channel in the plasma membrane of peripheral sensory neurons. Capsaicin channel agonists induce pain upon topical application in the early stage. which is followed by a period of desensitization. Although the agonists have been studied as a analgesics, their initial irritancy became sever side effect. So competive antagonists have been pursued as a novel pharmacological agent for analgesics, rather than agonists. (omitted)

  • PDF