• 제목/요약/키워드: Ion impurity

검색결과 152건 처리시간 0.026초

Ion Implantation으로 Ca를 첨가한 단결정 Al2O3의 Crack-like Pore의 Healing 거동 - I. Crack-like Pore의 형성과 Morphological Evolution (Effect of Ca Implantation on the Sintering and Crack Healing Behavior of High Purity Al2O3 Using Micro-lithographic Technique - I. Formation of Crack-like Pore and Its Morphological Evolution)

  • 김배연
    • 한국세라믹학회지
    • /
    • 제34권8호
    • /
    • pp.834-842
    • /
    • 1997
  • Controlled Ca impurity implanted inner crack-like pore in the high purity alumina single crystal, sapphire, had been created by micro-fabrication technique, which includes ion implantation, photo-lithography, Ar ion milling, and hot press technique. The morphological change and the healing of cracklike pore in Ca doped high purity single crystal alumina, sapphire, during high temperature heat treatment in vacuum were observed using optical microscopy. The dot-like surface roughening was developed and hexagon like crystal appeared on inner surface of crack-like pore after heat treatment. Bar type crystals, probably CaO.6Al2O3, were observed on the inner surface after 1 hour heat treatment at 1, 50$0^{\circ}C$, but this bar type crystal disappeared after 1 hour heat treatment at 1, $600^{\circ}C$. This disappearance means that there should be a little increase of Ca solubility limit to alumina at this temperatures.

  • PDF

The Study of the Charge Transport on the Surface Layer of the Patterned Vertical Alignment(PVA) Mode

  • Choi, Nak-Cho;You, Jae-Yong;Jung, Ji-Young;Rhie, Kung-Won;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.571-573
    • /
    • 2007
  • It is known that the main source of the area image sticking is the ion charge adsorption on the alignment layer. We found out that the adsorption of the ion charge of the liquid crystal in the cell was physisorption, which takes place between all molecules on any surface providing the adsorption force is small.

  • PDF

Ion Mass Doping 법을 이용한 Phosphorus 주입된 실리콘 박막의 Annealing 특성 (Annealing Characteristic of Phosphorus Implanted Silicon Films using an Ion Mass Doping Method)

  • 강창용;최덕균;주승기
    • 한국표면공학회지
    • /
    • 제27권4호
    • /
    • pp.234-240
    • /
    • 1994
  • A large area impurity doping method for poly-Si TFT LCD has been developed. The advantage of this method is the doping of impurities into Si over a large area without mass separation and beam scanning. Phosphorus diluted in hydrogen was discharged by RF(13.56MHz) power and ions from discharged gas were accelerated by DC acceleration voltage and were implanted into deposited Si films. The annealing characteristic of this method was similar to that of the ion implantation method in the low doping concentration. Three mechanisms were evolved in the annealing characteristics of phosphorus doped Si films. Point defects annihilation and the retrogradation of dopant atoms at grain boundaries as a result of grain growth played a major role at low and high annealing temperature, respectively. However, due to the dopant segregation, the reverse annealing range existed at intermediate annealing temperature.

  • PDF

Halo 구조의 MOSFET에서 이동도 감소 현상 (The Behavior of the Mobility Degradation in Pocket Implanted MOSFETS)

  • 이병헌;이기영
    • 대한전자공학회논문지SD
    • /
    • 제42권4호
    • /
    • pp.1-8
    • /
    • 2005
  • 소오스와 드레인 근처에 포켓이온이 주입된 halo구조의 MOSFET에서 전송자의 이동도 감소는 포켓이온주입의 조건에 따라 이온화된 불순물의 증가에 따른 쿨롱(Coulomb) 산란율의 증가에 의한 이동도의 감소량보다 큰 이동도의 감소가 관측될 수 있다. 게이트 바이어스에 대한 이동도의 특성변화도 기존의 일차적인 쿨롱산란의 증가효과에 의한 해석과 비교하여 상이한 결과가 나타날 수 있음이 실험적으로 확인되고 있다. 본 연구에서는 포켓이온 주입에 의하여 쿨롱산란원이 되는 유효불순물 농도의 증가에 따른 일차적인 이동도의 감소효과를 벗어난 이동도 특성을 분석하여 이동도의 감소현상을 일반적으로 설명할 수 있는 개선된 해석적 모델을 제시하였다. 해석적인 결과를 도출하기 위하여 일차원 영역구분의 근사방법을 적용한 결과, 포켓이온 주입에 의하여 포논산란율 및 표면산란율(surface roughness scattering rate)의 증가도 이동도감소에 기여함이 보여 졌다. 채널의 전송자분포가 드레인 전류에 영향을 미치게 되므로 포켓이온에 의해 유발된 전송자분포의 효과를 분석하여 유효이동도가 추가적으로 감소함을 확인하였다.

반도체 제조 이온주입 공정의 이온 임플란타 장치에서 엑스레이 발생 특성 (Characterization of X-ray Emitted in the Ion Implantation Process of Semiconductor Operations)

  • 박동욱;조경이;김소연;이승희;정은교
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.439-446
    • /
    • 2023
  • Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.

<100>방향 실리콘 단결정에서의 저 에너지 붕소 이온 주입 공정에 대한 3차원 몬테 카를로 시뮬레이션 및 마스크 효과 (Three-dimensional monte carlo simulation and mask effect of low-energy boron ion implantation into <100>single-crystal silicon)

  • 손명식;이준하;송영진;황호정
    • 전자공학회논문지A
    • /
    • 제32A권8호
    • /
    • pp.94-106
    • /
    • 1995
  • A three-dimensional(3D) Monte Carlo simulator for boron ion implantation into <100>single-crystal silicon considering the mask structure has been developed to predict the mask-dependent impurity doping profiles of the implanted boron at low energies into the reduced area according to the trend of a reduction in the size of semiconductor devices. All relevant important parameters during ion implantation have been taken into account in this simulator. These are incident energy, tilt and rotation of wafer, orientation of silicon wafer, presence of native silicon dioxide layer, dose, wafer temperature, ion beam divergence, masking thickness, and size and structure of open window in the mask. The one-dimensional(1D) results obtained by using the 3D simulator have been compared with the SIMS experiments to demonstrate its capabilities and confirem its reliability, and we obtained relatively accurate 1D doping profiles. Through these 3D simulations considering the hole structure and its size, we found the mask effects during boron ion implantation process.

  • PDF

NCM계 리튬이온 배터리 양극재의 수소환원 거동 (Hydrogen Reduction Behavior of NCM-based Lithium-ion Battery Cathode Materials)

  • 이소영;이소연;이대현;손호상
    • 한국분말재료학회지
    • /
    • 제31권2호
    • /
    • pp.163-168
    • /
    • 2024
  • As the demand for lithium-ion batteries for electric vehicles is increasing, it is important to recover valuable metals from waste lithium-ion batteries. In this study, the effects of gas flow rate and hydrogen partial pressure on hydrogen reduction of NCM-based lithium-ion battery cathode materials were investigated. As the gas flow rate and hydrogen partial pressure increased, the weight loss rate increased significantly from the beginning of the reaction due to the reduction of NiO and CoO by hydrogen. At 700 ℃ and hydrogen partial pressure above 0.5 atm, Ni and Li2O were produced by hydrogen reduction. From the reduction product and Li recovery rate, the hydrogen reduction of NCM-based cathode materials was significantly affected by hydrogen partial pressure. The Li compounds recovered from the solution after water leaching of the reduction products were LiOH, LiOH·H2O, and Li2CO3, with about 0.02 wt% Al as an impurity.

연속 이온 주입 공정 모델링 및 시뮬레이션 (Modeling and Simulation of Multiple Implantation Process)

  • 손명식;박수현황호정
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.557-560
    • /
    • 1998
  • We previously developed and presented the 3D ion implantation simulation code, TRICSI. In this paper, we performed the multiple implants into (100) silicon substrate with our recently enhanced version. Our results for the multiple implants were compared with the previously published SIMS data and obtained the good agreements. In this paper the channeling behaviour of implanted impurity and the damage accumulation are analyzed and discussed in the simple 3D structure, named the Hole structure which has a rectangular implant window.

  • PDF

Study on New Process of Zero Discharge of Cyanide Wastewater

  • Qiu, Ting-Sheng;Tang, Guan-Zhong;Hao, Zhi-Wei;Cheng, Xian-Xiong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.135-139
    • /
    • 2001
  • According to the requirement of cyanide precipitation-purification technology, adopt the acidized sulfate to precipitate cyanide. Studying the influence of acidity and the dosage of sulfate on precipitation rate of impurity ion in cyanide wastewater, and, on the basis of synthetic precipitation experiments, we obtain principle process of cyanide precipitation-purification to technology.

  • PDF

1 ${\mu}m$ CMOS 소자의 대칭적인 문턱전압 결정을 위한 최적 이온주입 시뮬레이션 (Simulation of optimal ion implantation for symmetric threshold voltage determination of 1 ${\mu}m$ CMOS device)

  • 서용진;최현식;이철인;김태형;김창일;장의구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.286-289
    • /
    • 1991
  • We simulated ion implantation and annealing condition of 1 ${\mu}m$ CMOS device using process simulator, SUPREM-II. In this simulation, optimal condition of ion implantation for symmetric threshold voltage determination of PMOS and NMOS region, junction depth and sheet resistance of source/drain region, impurity profile of each region are investigated. Ion implantation dose for 3 ${\mu}m$ N-well junction depth and symmetric threshold voltage of $|0.6|{\pm}0.1$ V were $1.9E12Cm^{-2}$(for phosphorus), $1.7E122Cm^{-2}$(for boron) respectively. Also annealing condition for dopant activation are examined about $900^{\circ}C$, 30 minutes. After final process step, N-well junction, P+ S/D junction and N+ S/D junction depth are calculated 3.16 ${\mu}m$, 0.45 ${\mu}m$ and 0.25 ${\mu}m$ respectively.

  • PDF