• Title/Summary/Keyword: Investigation Method

Search Result 6,788, Processing Time 0.044 seconds

Study on Improvement of Fire Investigation System (화재조사제도 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2009
  • As the current fire investigation system in Korea has been performed mainly by the public sector such as fire service, police, etc., private fire investigation system such as 'private fire investigator system' to protect rights and interests of the sufferers from the fire accidents due to defective products showed very deficient. In addition, since the laws and regulations concerned about fire investigation are distributed into and applied for each organization, a lot of problems have been generated such as civil appeals due to duplicated investigations among similar organizations, excess reaction to exclude other organization from the fire investigation field, inefficient waste of administration force due to duplicated operation of fire investigation organization and manpower, etc. This study has surveyed generation operation conditions and problems of the fire investigation system in Korea and drawn its improvement method on the public and private sectors.

Investigation on the Spot for Grounding Systems in Buildings

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.39-45
    • /
    • 2010
  • This paper deals with investigation on the spot for grounding systems of buildings based on international standards at construction sites. The investigation was carried out for grounding method, grounding type, shape of grounding electrode, grounding for a lightning protection system, continuity of steelwork in reinforced concrete structures, etc. The investigation on the spot was performed by a researcher and engineer with over fifteen years of industry experience all over the country. As a result of the investigation on the spot in 13 buildings, common grounding and structure grounding methods were dominant. The safety improvement methods include installation of equipotential bonding conductors for the connection to the main earthing terminal, equipotential bonding conductors for supplementary bonding, use of Surge Protective Devices (SPD), and safe connections between earthing conductors and the rebar.

Rapid Screening Method for the Solid-Phase Extraction and GC/MS analysis of Diazepam.

  • Choi, Hwa-Kyung;Lee, Ju-Seon;Choi, Hye-Young;Woo, Sang-Hee;Park, Yoo-Sin;Chung, Hee-Sun
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.118.3-119
    • /
    • 2003
  • Diazepam (DZ) is one of the most frequently prescribed drugs as an antianxiety agent, muscle relaxant, and anticovulsant and sometimes causes intoxication due to accidental overdose, misuse or abuse. Screening or confirmation methods for DZ and NDZ in plasma are very important for clinical and toxicological studies and in forensic cases. GC/MS assay with SPE was developed for the determination of diazepam and its metabolite, nordiazepam in human plasma. Diazepam in plasma was extracted by a rapid and sensitive procedure based on C18 bonded-phase extraction. (omitted)

  • PDF

A Study for Hydrodynamic Forces Action on Structural Parts of Semi-submersible Units. (반체수식 해양구조물의 요소부제에 작용하는 유체력)

  • 박노식
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.124-130
    • /
    • 1994
  • This paper compared with the hydrodynamic interference acting on the semi-submersible element model with 1-lowerhull and 2-columns. In this case, calculation are applying the strip method and 3-dimensional source distribution method. As the wave frequency and the distance between increase, the influence effects of parts upon each other decrease and approach the results calculated by using the strip method. Thus, it can be prepared for the investigation of new practical method of investigation of new practical method of hydrodynamic forces acting on huge structures.

  • PDF

Cost-effective Investigation on Contaminated Land and Assessment of Measurement Uncertainty (오염토양의 효율적 조사기법과 측정불확도의 평가방법)

  • 이종천
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.49-59
    • /
    • 2004
  • The concectration and distribution of contaminants obtained from a contaminated land investigation or an environmental geochemistry survey constitutes the basis of a decision-making process on environmental policies or of scientific researches. As the quality of data determines the reliability of the result, the investigation plan should be adjusted according to the purpose of the investigation. In general, the effort to improve the data quality had been focused mainly on the QA/QC procedures in laboratories. The rapid progress of analytical instrument has also contributed toward improving the analytical precision to a sacrificable degree. Nevertheless, in many cases, it is not the analytical precision that needs improvement for the better precision of overall measurement process: it is rather during the sampling process in the field that is responsible for the poor precision. To assess the data quality on a measured value, ISO recommends to provide information on "measurement uncertainty" along with the measured value. The measurement uncertainty in an environmental measurement context can be explained as the statistical number that expresses the degree of the uncertainty stemming from the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of the whole investigation process. This paper aims to present a method of estimating the level of measurement uncertainty of a measured contamination concentration at a site used as an example and to show how the estimated uncertainty can be applied to serve the particular purpose of an investigation.

Investigation of Physical and Mechanical Properties for a Central Core Rockfill Dam (중심코아형 록필댐 제체의 물리적 및 역학적 특성 조사)

  • 신동훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.345-350
    • /
    • 1999
  • In this study the results of investigation on the physical and mechanical properties of a rockfill dam body were provided. On the crest of the old Namgang dam to be excavated partially, various in-situ tests(boring with SPT, sampling of undisturbed sample, field density test, field permeability test) and geophysical investigation works were performed Rock materials, i.e., shale and sandstone, were collected, and their slake durability was evaluated using slaking durability testing method which is suggested by ISRM.

  • PDF

Investigation and Assesment of Ground Contamination around Waste Landfill (폐기물매립지 주변 토양 및 지하수 오염도 조사 및 분석)

  • 정하익;김상근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.116-119
    • /
    • 2000
  • There has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation on contaminant and leachate flume in the ground and landfill. In this study, investigation and assesment on soil and groundwater around the waste landfill was carried out. Many techniques such as drilling and sampling method were applied. As a result of this study, the concentration of soil and groundwater were investigated and analysed.

  • PDF

Off-Line Navigation System for PIG(Pipeline Investigation Gauge) (PIG 시스템에 적용된 오프라인 항법시스템)

  • Yu, Jae-Jong;Han, Hyung-Seok;Park, Chan-Gook;Lee, Jang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.224-227
    • /
    • 2002
  • In this paper, PIG(Pipeline Investigation Gauge) system is introduced and off-line navigation method for the system is studied. Off-line navigation is obtained by using a smoothing filter and the position of the point with some problems in gas pipeline can be detected with a good accuracy in real pipeline investigation experiment.

  • PDF

Scientific fire investigation by NFPA 921 CODE based on frozen warehouse fire case (냉동창고 화재 사례를 기반으로 하는 NFPA 921 CODE에 의한 과학적 화재조사 연구)

  • Park, Kyong-Jin;Lee, Yong-KI;Cha, Sung-Sig;Jung, Dong-Young;Kim, Jang-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we investigated the cases where there were many opinions in the judgment of the cause of ignition in the case of 20 cases of frozen warehouse fire that occurred in 2017.The research methodology is the scientific fire survey method prescribed by the NFPA 921 CODE. Scientific fire investigation method is fire investigation method by logical reasoning through hypothesis setting, minimizing errors in judgment of ignition source. On the other hand, unscientific fire investigation methods cause many errors by the intervention of irrational factors such as subjective estimation, reasoning judgment, etc. This eventually leads to the problem of human and material responsibility and academic deterioration. In particular, fire not seen as compared to sighted fire makes more errors in ignition sources in the cause investigation. In this study, we set the hypothesis A and hypothesis B based on the review of the fire investigation report and the field survey on the fire case of the cold storage warehouse front line that occurred at ** city ** Mart in 2017.The set hypothesis was tested by the NFPA 921 code. This analytical method will be constructed by NEW Paradigm as a source of fire that is not seen in the future and a source of ignorant fire.In addition, the experimental data of this study will be used to inform the manufacturer and operator of the refrigeration warehouse and serve as basic data for fire prevention.