A Study on Power Conversion System of the High Speed Train (고속전철 견인용 전력변환장치에 관한 연구)

  • 이병송;박성혁;변윤섭;김명룡;이수길;박현준
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.275-282
    • /
    • 1999
  • This paper presents the current-fed inverter of a TGV-K traction system with thyristor switches using phase control and commutation techniques. The current-fed inverters have two modes of operation which consist of forced commutation and natural commutation. In forced commutation mode, at speed of less than 120km/h, commutation is forced by means of the commutation capacitors and the thyristors. Above 120km/h, the thyristors operate in natural commutation mode, according to the voltages between phases of the motors. In this paper, the power conversion theory of the TGV-K traction system and the control principle of the converter and current-fed inverter are discussed.

  • PDF

Field Weakening Control of Permanent Magnet Synchronous Motor fed by Hysteresis Current Controlled PWM Inverter (히스테리시스 전류 제어형 PWM 인버터에 의한 영구자석 동기 전동기의 약계자 제어)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Yang, Chun-Suk;Yoon, Myung-Kyun;Yoo, Bo-Min
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.167-170
    • /
    • 1991
  • The back e.m.f. of PMSM is increased as the speed is increased and it saturates the current regulator because it counteracts the available output voltage of the inverter. In the PM motor, however, the required armature terminal voltage can be reduced within the maximum output voltage of the inverter by field weakening control, in which the air gap flux is weakened by the d-axis armature current. In this paper, the field weakening control of the surface PMSM fed by a hysteresis current control led PWM inverter based on the microprocessor is presented. To show the validity of the proposed control method, the simulation and experimental results are provided.

  • PDF

A New Space Vector Random PWM Scheme for Inverter Fed Drive Systems (인버터 구동 시스템을 위한 새로운 공간벡터 Random PWM기법)

  • 나석환;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.525-537
    • /
    • 2001
  • In this paper a new space vector RPPWM(Random Position PWM) is proposed. In the propsed RPPWM each of three phase pulses is located randomly in each switching interval. Based on the Space vector modulation technique the duty ratio of the pulses is calculated Along with the randomization of the PWM pulses. we can obtain the effects of spread spectra of votlage, current as in the case of randomly changed switching frequency, To verify the validity of the proposed RPPWM simulation study was tried using Matlab/Simulink The main model described in Simulink block diagrams includes the space vector modulation block pulse position randomization block inverter block 3 phase induction motor block and so on By the simulation study, the harmonics of the output voltage and the current of inverter are predicted in different PWM methods- SVPWM, LLPWM proposed RPPWM.

  • PDF

Rotor Fault Detection System for the Inverter Driven Induction Motor using Current Signals

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Choi, Chang-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.224-231
    • /
    • 2009
  • The induction motor rotor fault diagnosis system using current signals, which are measured using an axis-transformation method, is presented in this paper. In inverter-fed motor drives, unlike line-driven motor drives, the stator currents are rich in harmonics; therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, and encoder, etc. The proposed axis-transformation method with encoder and without encoder is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation is compared with the results obtained from fast Fourier transforms.

High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals (오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템)

  • Kim, Nam-Hun;Kim, Min-Heui;Choi, Chang-Ho;Lee, Sang-Hoon;Choi, Keyng-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

Current-controlled PWM for voltage source single phase inverter (전류제어 PWM에 의한 단상 인버어터 제어)

  • Park, Hoon-Kyung;Lee, Kwang-Won;Lee, Sang-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.277-280
    • /
    • 1988
  • In the current-controlled PWM, the actual current tracks the sinusoidal reference wave within desired hyeteresis band. This paper au99e61s the current control scheme for voltage-fed single-phase inverter and presents the simulation results. It is expected that the inverter with this control method produces no significant lower-order harmonics.

  • PDF

EFFICIENT OZONIZER USING VOLTAGE-SOURCE LOAD RESONANT INVERTER WITH PDM AND PWM CONTROL IMPLEMENTATION

  • Kohishi, Yoshihiro;Wang, Shengpei;Shirakawa, Shinya;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1024-1029
    • /
    • 1998
  • In this paper, the voltage-fed series compensated inductor type load-resonant high-frequency inverter is originally presented for driving a newly-developed silent discharge ozone generating tube. The effective power regulation scheme of this ozonizer is proposed, which is based on PDM (Pulse Density Modulation) related PWM strategy due to DSP implementation. The effectiveness of this inverter type ozonizer is proved in simulation and experiment.

  • PDF

Novel ZCS-PFM Series Resonant High Frequency Inverter for Electromagnetic Induction Eddy Current-Heated Roller

  • Mun, Sang-Pil;Kang, Shin-Chul;Kim, Soo-Wook;Nakaoka, Mutsuo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.7
    • /
    • pp.28-36
    • /
    • 2008
  • This paper presents a novel prototype of zero current switching pulse frequency modulation (ZCS-PFM )high frequency series resonant inverter using IGBT power module for electromagnetic induction eddy current heated roller in copy and printing machines. The operating principle and unique features of this voltage-fed half bridge inverter with two additional soft commutation inductor snubber are presented including the transformer modeling of induction heated rolling drum. This soft switching inverter can achieve stable zero current soft commutation under a discontinuous and continuous resonant load current for a widely specified power regulation processing. The experimental results and computer-aided analysis of this inverter are discussed from a practical point of view.

Half-bridge Cascaded Multilevel Inverter Based Series Active Power Filter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.777-787
    • /
    • 2017
  • A new single phase half-bridge cascaded multilevel inverter based series active power filter (SAPF) is proposed. The main parts of the inverter are presented in detail. With the proposed inverter topology, any compensation voltage reference can be easily obtained. Therefore, the inverter acts as a harmonic source when the reference is a non-sinusoidal signal. A 31-level inverter based SAPF with the proposed topology, is manufactured and the voltage harmonics of the load connected to the point of common coupling (PCC) are compensated. There is no need for a parallel passive filter (PPF) since the main purpose of the paper is to represent the compensation capability of the SAPF without a PPF. It is aimed to compensate the voltage harmonics of the load fed by a non-sinusoidal supply using the proposed inverter. The validity of the proposed inverter based SAPF is verified by simulation as well as experimental study. The system efficiency is also measured in this study. Both simulation and experimental results show that the proposed multilevel inverter is suitable for SAPF applications.

Design of Digital PWM Controller for Voltage Source Inverter (전압형 인버터를 위한 디지털 PWM 제어기 설계)

  • 이성백;이종규;정구철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.27-33
    • /
    • 1993
  • This paper presents the &tal controller for driving high frequency voltage fed PWM inverter that carrier frequency is over 2OkHz.We analyzed the conventional PWM to select a proper PWM pattern. as the result, obtained PWM pattern of the controller in which asynchronus staircase sinusoidal waveform is used as reference signal, and variable carrier ratio method was used for PWM control. The PWM controller is designed by fully digital method. Especially, Thk proposed controller is consisted of 8 bit one-chip microprocessor and digital logic. the former is for arithmetic and data processing, and the latter is for PWM pattern synthesis. Therefore, The responsibility and controllability is improved. Also, Data processing capability is improved using proper program to output modulation index with 9 bits. Circuits configuration of digital controller are made up of one chip 8051 and EPLD, and its controllability is tested by operating voltage fed inverter. Harmonics and current waveform is evaluated and analyzed for the voltage fed inverter system.

  • PDF