A Novel Input and Output Harmonic Elimination Technique for the Single-Phase PV Inverter Systems with Maximum Power Point Tracking (최대출력추종 제어를 포함한 단상 태양광 인버터를 위한 새로운 입출력 고조파 제거법)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.207-209
    • /
    • 2019
  • This paper proposes a grid-tied photovoltaic (PV) system, consisting of Voltage-fed dual-active-bridge (DAB) dc-dc converter with single phase inverter. The proposed converter allows a small dc-link capacitor, so that system reliability can be improved by replacing electrolytic capacitors with film capacitors. The double line frequency free maximum power point tracking (MPPT) is also realized in the proposed converter by using Ripple Correlation method. First of all, to eliminate the double line frequency ripple which influence the reduction of DC source capacitance, control is developed. Then, a designing of Current control in DQ frame is analyzed and to fulfill the international harmonics standards such as IEEE 519 and P1547, $3^{rd}$ harmonic in the grid is directly compensated by the feedforward terms generated by the PR controller with the grid current in stationary frame to achieve desire Total Harmonic Distortion (THD). 5-kW PV converter and inverter module with a small dc-link film capacitor was built in the laboratory with the proposed control and MPPT algorithm. Experimental results are given to validate the converter performance.

  • PDF

Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type (전류주입식 능동전력 필터를 위한 최적주입방법의 해석)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.7
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

The Analysis of the torque ripple of Traction Motor in the VSI system (전압원 인버터 파형에 따른 견인 전동기의 맥동 토오크 해석)

  • Rhee, Kee-Hong;Yun, Shin-Yong;Kim, Yong;Baek, Su-Hyun;Kang, Ho-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.145-147
    • /
    • 1996
  • Traction Motor is being transferred to the squirrel cage induction motor from D.C motor, by the improved power semiconductors like GTO, IGBT, etc. In the Induction Motor, inverter system must be used for delivering variable voltage variable frequency. But, by pulsating in the system the harmonics would be produced, and that cause the torque ripple and enfeeble the dynamic characteristics of the motor. So, to use the inverter system, we should take the torque ripple into consideration. To minimize the torque ripple in the VSI fed Traction Motor, the optimal pulsating was presented in this paper. By using the SPWM(Sinusoidal Pulse Width Modulation) method, feeding the appropriate pulse, we can minimize the torque ripple and improve the transient response.

  • PDF

Resonant capacitor with separate4 Induction heating system (공진 콘덴서 분할형 유도가열 전원장치)

  • Lee, B.S.;Min, B.J.;Kim, D.H.;Ro, C.C.;Jung, S.K.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.502-504
    • /
    • 1994
  • This paper describes an induction heating system which is full-bridge parallels resonant inverter. This system consists of current-fed type inverter, and a parallels resonant circuit with a matching transformer. A parallels resonant scheme is employed, and operating range of the proposed circuit with operating frequency and load parameter is demonstrated from the result of steady state. Also, this equipments testing result introduces, good efficiency and reliability of the system. Finally, this paper experimental results are given.

  • PDF

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

New Switching Strategy of PWM Inverter Controlled by Microprocessor (마이크로 프로세서로 제어되는 PWM 인버터의 새로운 스위칭 방식)

  • 이윤종;서기영;정동화
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.623-635
    • /
    • 1987
  • A new suboptimal PWM is proposed, intended particularly for the reduction of acoustic noise and harmonics of the output current in the inverter-fed induction motor drive system. This strategy is based of the Regular PWM and applied optimal techniqe. And it could solve a problem that computation time is very much when switching strategy is determined at the Optimal PWM. In case that the number of switching increases infinitely, this strategy could determine the switching pattern, and can realize Online, Real time of microprocessor. Also, this strategy is applied to 1(Hp), three phase induction motor, and compared with the other PWMs. From the results, the validity of this strategy could be verified.

  • PDF

Dynamic Characteristics Analysis of Induction Motor by Using Inverter (인버터 구동형 유도전동기의 동특성 해석)

  • Koo, Dae-Hyun;Kim, Kyung-Ho;Lee, Boung-Sam;Han, Jin-Woo;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.927-929
    • /
    • 2001
  • Induction Motor fed by PWM inverter generates the sound and the vibration because of harmonic current and magnetic force characteristics. This paper is investigated the harmonic frequency and noise characteristics of the current and the torque of the induction motor when the input voltage is excited as the sine wave or PWM wave. The performance characteristics of induction motor is analyzed by the F.E.M and the theoretical method.

  • PDF

A Study on the Output Characteristics of Linear Induction Motor using Flux observer (자속 관측기를 이용한 리니어모터 출력특성에 관한연구)

  • Jang, Youn-Hae;Lim, Hong-Woo;Seo, Kang-Sung;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1160-1164
    • /
    • 2001
  • The input voltage of linear Induction motors(LIMs) is involved with the time harmonics because most LIM is driven by inverter. Therefore the equivalent circuit for an inverter-fed LIM has to be modifided to represent every harmonic present in supply voltage. This paper describes that the dynamic characteristic can be used effectively for analyzing the characteristics of a linear induction motor position and speed control.

  • PDF

The Stablized Control Method for The Voltage Source Inverter Fed Induction Motor Driver (전압형 인버터로 구동되는 유도기의 안정화 제어)

  • Ro, S.C.;Lee, H.W.;Lee, O.G.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.567-570
    • /
    • 1989
  • A constant V/F control system of voltage contrlled PWM inverter has a unstable operation of the low- speed and the light-load. In this paper, the authors propose stability control with idealized operation of induction motor by the neglect of primary leakage inductance and resistance. Also ldealized operation system is adopted voltage error, feed back impedance circuit, and increasing resistance from dead time of switching is compensated by the soft ware with u-processors. The proposed simulation of the idealized control method is proved at the low-speed operation for three phase induction motor.

  • PDF

Microprocessor - based Self - controllers for the drive of Permanent Magnet Synchronous Motors - (마이크로 프로세서에 의한 영구자석 동기 전동기의 자기제어기(自己制御器) 설계 및 구동)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Lee, Young-Suk;Kim, Eel-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.283-287
    • /
    • 1989
  • This paper presents a microprocesser based Self-Controller for a Permanent Magnet Synchronous Motor(PMSM), fed by voltage soure inverter. The proper operation of the PMSM can be ensured only if the stator current is always synchronized with the its Back-E.M.F. The use of incremantal encoder with high resolution makes it possible to design a Self-Control led P.W.M. inverter. The pulse ratios are controlled to reduce the torque ripple in the low-speed drive region. And during the operation, torque - speed characteristics are improved by the control of optimal load angle.

  • PDF