• Title/Summary/Keyword: Inverter systems

Search Result 820, Processing Time 0.023 seconds

Cascaded Multi-Level Inverter Based IPT Systems for High Power Applications

  • Li, Yong;Mai, Ruikun;Yang, Mingkai;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1508-1516
    • /
    • 2015
  • A single phase H-bridge inverter is employed in conventional Inductive Power Transfer (IPT) systems as the primary side power supply. These systems may not be suitable for some high power applications, due to the constraints of the power electronic devices and the cost. A high-frequency cascaded multi-level inverter employed in IPT systems, which is suitable for high power applications, is presented in this paper. The Phase Shift Pulse Width Modulation (PS-PWM) method is proposed to realize power regulation and selective harmonic elimination. Explicit solutions against phase shift angle and pulse width are given according to the constraints of the selective harmonic elimination equation and the required voltage to avoid solving non-linear transcendental equations. The validity of the proposed control approach is verified by the experimental results obtained with a 2kW prototype system. This approach is expected to be useful for high power IPT applications, and the output power of each H-bridge unit is identical by the proposed approach.

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

Design of a Single-stage Electronic Ballast using a Half-Bridge Resonant Inverter

  • Son, Young-Dae
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.104-111
    • /
    • 2001
  • The design procedures and experimental results of a single-stage electronic ballast using half-bridge resonant inverter are presented in this paper. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bradge series resonant inverter. High power factor is achieved by using the boost semi-stage operating in discontinuous conduction mode and inverter semi-stage operated above resonant frequency to provide zero voltage switching is empolyed to ballast the fluorescent lamp Experimental results from the ballast system with 36W fluorescent

A Study on Constant Power Control of Half Bridge Inverter for Microwave Oven

  • Lee, Min-Ki;Koh, Kang-Hoon;Lee, Hyun--Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.73-79
    • /
    • 2004
  • For the global microwave market, high RF power or deluxe model is applying for inverter gradually. In this paper, 120[V]/1200[W] high power inverter is proposed and verified by an optimized design of PFM type. Especially the steady power output control was fulfilling at +/- 10[%] input voltage variation.

The characteristic analyses and output frequency tracking control of a high frequency inverter (고주파 인버터의 특성해석 및 출력주파수 추종제어)

  • 이종무;김영석;조기연
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.597-602
    • /
    • 1987
  • This paper proposes a voltage-fed high frequency resonant inverter having variable voltage variable frequency(VVVF) control function. VVVF control is performed by PWM-TRC method in the boost type chopper and PFM-TRC method in the high frequency resonant inverter. This circuit is suitable for induction heating and melting power supply in industry. The operating characteristics of this inverter are discussed from a theoretical point of view. The results of operating characteristic analyses are given leading to complete designing data.

  • PDF

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Modeling and Simulation Technique of Two Quadrant Chopper and PWM Inverter-Fed IPMSM Drive System and Its Application to Hybrid Vehicles

  • Murata, Toshiaki;Kawatsu, Utaro;Tamura, Junji;Tsuchiya, Takeshi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2012
  • This paper presents a state space model of a two quadrant chopper and PWM inverter-fed Interior Permanent Magnet Synchronous Motor (IPMSM) drive system and its application to hybrid vehicles. The drive system has two different state equations for motoring and regenerating action. This paper presents a common state equation by using State Space Averaging method. Using this model of the IPMSM drive system, detailed simulation and controller design of the drive system, including PWM inverter switching, are given. The validity of this model and usefulness, according to a comparison among Maximum Torque/Ampere control, Maximum Torque/Flux control, and Maximum Efficiency optimization, are confirmed from simulation results.

A New Switching Pattern for Multilevel Inverter Based on Selective Harmonic Elimination Using Genetic Algorithm

  • Fekari, Seyyed Amir;Iranaq, Ali Reza Marami;Sabahi, Mehran
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.305-311
    • /
    • 2014
  • In this paper, a new switching pattern is presented for multilevel inverters. With changing off-angel of each switch, the on time interval of all switches will approximately be equal and then the lifetime of inverter will increase, also using this method can reduce electrical stress on switches in higher levels of inverter. Switching angels as for desired modulation index are calculated using genetic algorithm whereas selective harmonics are controlled within the allowable range. The computed angels are simulated in Matlab/Simulink for respective circuits to validate the results.

Harmonics Elimination in a Multilevel Inverter with Unequal DC Sources Using a Genetic Algorithm

  • Iranaq, Ali Reza Marami;Kouhshahi, Mojtaba Bahrami;Kouhshahi, Mehdi Bahrami;Sharifian, Mohammad Bagher Bannae;Sabahi, Mehran
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.77-83
    • /
    • 2012
  • In this paper, an optimal solution to the harmonic reduction problem in a cascaded multilevel inverter with non-equal DC sources using a genetic algorithm (GA) is presented. Switching angles are generated for different values of modulation index by the proposed algorithm, considering minimum voltage total harmonic distortion (THD) whereas selected harmonics are controlled within the allowable limits at all desired modulation indices including the point of discontinuity. Results are stored as a look-up table to be used to control the inverter for a certain operating point. The computed angles are used in a simulated circuit in Matlab\Simulink to validate the results.

Cascaded H-bridge Multilevel Inverter for High Precision and Linear Control of the Rate of Ozone Yielding

  • Park, Sung-Jun;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • A multilevel inverter employing a cascade transformer is proposed for a silent-discharge-tube ozone generating system. The proposed inverter consists of four full-bridge inverters and fourteen transformers which have a series-connected secondary. It can accurately control the amplitude of the output voltage; hereby, it improves a linear characteristic of the rate of ozone yielding. The power regulation characteristics and operational principle of the proposed system are explained from a practical point of view. High precision ozone generating performance of the proposed multilevel inverter is verified by computer-aided simulations and experiment results.