• Title/Summary/Keyword: Inverter module

Search Result 243, Processing Time 0.027 seconds

Installation and Performance Evaluation of 100kWp PV System in Tibet (중국 티베트지역의 100kWp급 태양광발전시스템 실증연구)

  • Kim Seok-Ki;Yun Jae-Ho;Lee Jeong-Chul;Ahn Se-Jin;Yoon Kyung-Hoon;Song Jin-Soo
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.16-22
    • /
    • 2006
  • This paper present the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea.

  • PDF

1.2 MHz Wireless Power Transfer Technology using a Spiral-type ECR device (1.2 MHz 스파이럴 ECR을 이용한 무선전력전송 기술)

  • PARK, Jaehyun;YANG, Haeyoul;KIM, Changsun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.54-55
    • /
    • 2011
  • To transfer the power wirelessly, the inverter converted DC power to a high frequency MHz-grade AC power. And the ECR devices for wirelessly transmitting the power are required. In this paper, the spiral-type ECR device and the high frequency inverter were designed. The operating frequency is approximately 1.2MHz. In addition, using a vector network analyzer, the 1.2MHz operating characteristics of the ECR device for wireless power transfer module are analyzed. It is performed and reviewed on validity of wireless power transfer technologies through experiments.

  • PDF

The operating characteristics of a small-scale residential PV power system (소규모 주택용 태양광 발전시스템의 운전 특성)

  • Ahn, K.S.;Lim, H.C.;Kang, B.S.;Hwang, I.H.;Kim, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1284-1286
    • /
    • 2001
  • In this paper, the operating characteristics of a 3 kW class grid-interactive photovoltaic(PV) power system was analysed from January 1998 to December 2000. The construction of the PV system includes a DC/AC inverter for grid connection, PV module, and data Monitoring & Acquisition system. The major results of the field test of the 3 kW class grid-interactive PV system showed that the system utilization rate was 13.83% the conversion efficiency of the inverter was 88% at an over half load, and the PV system generated the electricity more then 300 kWh per month.

  • PDF

A Study on Performance Improvement of Sensorless Operation of the Brushless DC Moter in Low Speed Region (저속영역에서의 브러시리스 직류전동기의 센서리스 운전 성능 향상에 대한 연구)

  • Seo Mun-Seok;Bae Jong-Pyo;Choe Jae Hyeok;Kim Jong-Sun;Yoo Ji-Yoon;Yeo Hyeong-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.124-128
    • /
    • 2002
  • This Paper propose a novel sensorless drive system for the trapezoidal brushless DC motor in Bow speed region. The inverter DC input voltage is controlled by step-down converter for low speed operation. A indirect rotor position sensing technique based on a detailed analysis of the terminal voltage characterisrics is proposed in this paper. A sensorless drive system is implemented using a TMS320F240 for the main process and IPM(Intelligent Power Module) for the inverter.

  • PDF

The Development of AC Motor Control System Using DIP-IPM (DIP-IPM을 이용한 전동기 제어시스템 개발)

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Kim, Dong-Hee;Choi, Ho-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.232-234
    • /
    • 2002
  • Due to development of power electronics technology, power conversion system are tend to small size, easy to use and light weight. Especially motor control system have increased concerns and interests about IPM(Intelligent Power Module) inverter, which contains protection circuit, drive circuit and power devices. So, we manufactured 3-phase inverter using DIP-IPM(Dual in-line package IPM) PS21245- E(1.5 Kw) made by MITSUBISHI Electric. Some of these features include -HVIC to Provide level shifting and gate drive for high-side IGBTs. The interface circuit between pwm controller and DIP-IPM can made by direct connection. In order to validate dynamic performance of the proposed system, the actual experiment worked out at wide speed range. The developed system is shown as a good dynamic characteristics.

  • PDF

A Study on Characteristic of Power Conversion System of the Photovoltaic Using a Solar Position Tracker (위치 추적기를 사용한 태양광 발전의 전력 변환시스템 특성에 관한 연구)

  • Hwang, L.H.;Jang, J.H.;Na, S.K.;Kim, Y.S.;Ahn, I.S.;Cho, M.T.;Song, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1034-1036
    • /
    • 2006
  • In this paper, I used microprocessor and sensor and designed to improve the efficiency of the photovoltaic system the photovoltaic position tracker device, and compared the normal photovoltaic system of fixed form with the photovoltaic system of solar position tracked form. Moreover, compared the catalogue of solar cell module and the simulation through a mathematics modelling with the solar cell's characteristic interpreting and, composed an power conversion system with boost converter and voltage source inverter. Used the constant voltage control method for maximum power point tracking in boost converter control and, used the SPWM(Sinusoidal Pulse Width Modulation) control method in inverter control.

  • PDF

Range Extension of Input Voltage of Flyback Inverter for Photovoltaic AC Modules (PV-AC 모듈형 단상 플라이백 인버터의 입력 전압 범위 확장 기법)

  • Noh, Yong-Su;Kim, Jun-Gu;Ji, Young-Hyok;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.51-52
    • /
    • 2012
  • Among the PV-AC module topologies, the flyback inverter have been occupied the attention due to its simplicities on configuration and control. Proposed switching control method changes the mode of operation in DCM and BCM alternatively. It is expected that the high performances in efficiency and extension of input voltage range can be achieved by the conduction mode change. Proposed switching technique is validated by PSIM simulation.

  • PDF

ZVS Parallel Active Power Decoupling Circuit for Applying Flyback Inverter (플라이백 인버터에 병렬로 적용되는 ZVS 방식의 전력 디커플링 회로에 관한 연구)

  • Kim, Mi-Na;Noh, Yong-Su;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.55-56
    • /
    • 2012
  • In general, a power decoupling method using electrolytic capacitor is used to solve a problem that appears 120[Hz] ripple of grid at the PV module output. But electrolytic capacitor has a effect on the short lifetime and low reliability of PV system. Therefore, studies which replace the large electrolytic capacitor with small film capacitor have been researched in resent years. This paper proposes flyback inverter which can be replaced with film capacitor by connecting the circuit implementing zero voltage switching in PV side. The proposed system is validated by PSIM simulation.

  • PDF

An analysis on the operating characteristics of 50kW Photovoltaic Power System (50 kW급 계통연계형 태양광 발전시스템 장기 실증 운전)

  • Kim, Y.S.;Ahn, K.S.;Lim, H.C.;Oh, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1788-1790
    • /
    • 2005
  • In this paper, an operating characteristics of a 50 kW gird-connected photovoltaic(PV) power system was analysed from 2000 to 2004. The construction of the PV system includes a 3-phase inverter for grid connection, PV module, distribution box, and data monitoring system. The major results of the demonstration test of the 50 kW class gird-connected PV system showed that efficiency of PV system was 11.13%, and the conversion efficiency of the inverter was 92% at a 50% load.

  • PDF

Installation and Performance Evaluation of 100kWp PV System in Tibet (중국 티베트지역의 100kWp급 태양광발전시스템 실증연구)

  • Kim, Seok-Ki;Yun, Jae-Ho;Lee, Jeong-Chul;Aha, Se-Jin;Yoon, Kyung-Hoon;Song, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.125-129
    • /
    • 2006
  • This paper presents the isolation and performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module by using Koreans solar cells, constructed site and built control house.

  • PDF