• Title/Summary/Keyword: Inverter driven

Search Result 289, Processing Time 0.024 seconds

인버터용 유도전동기의 특징 (Characteristics of inverter-driven induction motor)

  • 조규진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.60-63
    • /
    • 1991
  • Nowadays inverters are widely used for energy-saving and factory automation. Accordingly the characteristics and functions of the inverter are well understood. To our surprise, the characteristics and functions of the inverter-driven induction motor are not well understood. In this technical review, the electrical and mechanical characteristics of the inverter-driven motor, the optimal combination of the inverter with motor, the special design of the inverter-driven motor, and the application of the inverter with the existing motor are given, based on ABB Drives' experiences and technical data.

  • PDF

다중 인버터 구동 고속전철 시스템의 IPMSM 파라미터 변동에 따른 운전 특성 고찰 (Investigation of the IPMSM Parameter Variation Effect to the System Operation Characteristics of the Multi Inverter Driven High Speed Train System)

  • 박동규;진강환;장진영;김성제;김윤호
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.193-199
    • /
    • 2011
  • The next generation domestic high speed railway system is a power distributed type and uses vector control method for motor speed control. Nowadays, inverter driven induction motor system is widely used. However, recently PMSM drives are deeply considered as a alternative candidate instead of an induction motor driven system due to their advantages in efficiency, noise reduction and maintenance. The next-generation high-speed train is composed of 2 converter units, 4 inverter units, and 4 Traction Motor units. Each motor is connected to the inverter directly. In this paper, the effects of IPMSM parameter variation to the system operation characteristics of the multi inverter driven high speed train system are investigated. The parallel connected inverter input-output characteristics are analyzed to the parameter mismatches of the IPMSM in 1C1M control using Matlab/Simulink, then the reliability of the simulation results are verified through experimental results.

저역통과 LC필터를 가진 전브리지형 인버터로 구동되는 3상유동전동기의 속도제어 시스템에 관한 연구 (A Study on the Speed Control System of a 3 phase Induction Motor driven by the Full Bridge Inverter with a Low Pass LC Filter)

  • 박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.538-550
    • /
    • 1998
  • The variable frequency and variable voltage AC source made by a conventional inverter which is composed of power semi-conductors includes much noises in sine wave due to high frequency switching of DC source. In this paper the 3rd low pass LC filter for a variable speed 3 phase induction motor driven by a full bridge inverter is introduced to solve the EMI problem by serious noise current. The utility of a modified 3rd order Butterworth LC filter is confirmed through FFT analysis of sine waves and noiseless ACsource can be obtained by the proposed LC filter. The speed of a 3 phase induction motor driven by a full bridge inverter with a LC filter is satisfactorily controlled by a digital PID controller under the condition of stepwise load and setpoint changes.

  • PDF

고출력 MHL용 구형저주파 구동 방식의 전자식 안정기 설계 (Electronic Ballast Design Driven by Low Frequency Square Wave for High Power MHL)

  • 김기남;박종연;최영민
    • 전력전자학회논문지
    • /
    • 제15권5호
    • /
    • pp.394-400
    • /
    • 2010
  • 본 논문에서는 Buck Converter 동작 원리를 Full -Bridge Inverter에 적용한 전자식 안정기를 제안하였다. 전자식안정기는 EMI 필터, 수동 PFC, Full-Bridge Inverter로 2-stage로 구성되어 있다. PFC는 신뢰성 확보를 위해 수동 PFC를 사용하였다. Full-Bridge Inverter는 High Side와 Low Side 스위치의 구동 주파수를 각각 고주파와 저주파로 구동하여 Buck Converter의 동작을 구현 하였다. 램프를 저주파수 구형파로 구동하여 음향공명현상을 피하게 되었으며, 고주파수 스위칭으로 인덕터의 부피를 줄였다. 제안한 방법은 시뮬레이션과 실험을 통해 증명하였다.

Rotor Fault Detection System for Inverter Driven Induction Motors using Currents Signals and an Encoder

  • Kim, Nam-Hun
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.271-277
    • /
    • 2007
  • In this paper, an induction motor rotor fault diagnosis system using current signals, which are measured using the axis-transformation method is presented. Inverter-fed motor drives, unlike line-driven motor drives, have stator currents which are rich in harmonics and therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, an encoder and additional hardware. Therefore, the proposed axis-transformation method is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation, using the Park transformation, is compared with the results obtained from the FFT(Fast Fourier Transform).

Low Cost Rotor Fault Detection System for Inverter Driven Induction Motor

  • Kim, Nam-Hun;Choi, Chang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.500-504
    • /
    • 2007
  • In this paper, the induction motor rotor fault diagnosis system using current signals, which are measured using axis-transformation method, and speed, which is estimated using current information, are presented. In inverter-fed motor drives unlike line-driven motor drives the stator currents have numerous harmonics components and therefore fault diagnosis using stator currents is very difficult. The current and speed signal for rotor fault diagnosis needs to be precise. Also, high resolution information, which means the diagnosis system, demands additional hardware such as low pass filter, high resolution ADC, encoder and etc. Therefore, the proposed axis-transformation and speed estimation method are expected to contribute to low cost fault diagnosis systems in inverter-fed motor drives without the need for an encoder and any additional hardware. In order to confirm validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation and speed estimation method are compared with the results obtained from fast Fourier transforms.

인버터 압축기의 강체 거동 해석 (Dynamic Analysis of an Inverter Motor Driven Compressor)

  • 강정훈;정정교;김용태;주재만;서문희;이성태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.79-82
    • /
    • 2004
  • In general, compressors for refrigerators are major noise source in home environment. The vibration originated from a pump of a compressor can make noise through suspension springs and a LDT(Line Discharge Tube). Especially for the inverter motor driven compressor, the vibration is more serious than it of the constant speed compressors. Because the operation frequency range of an inverter motor driven compressor is very wide from 1600 rpm to 4200 rpm. In this paper, we propose the numerical model to reduce vibration by designing weight balancers and grommets. Results for analytical investigations on the exciting force and moment at the pump mass center, weight balancers and exciting frequency variation are presented.

  • PDF

전압원 구동시의 전류형 인버어터의 특성연구 (A Study on characteristics of Current-Fed Type Inverter driven by Voltage Source)

  • 이달해;김동희;이봉섭;유동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.587-590
    • /
    • 1991
  • It is general to make the circuit analysis of current-fed type inverter driven by current source with rippleless input under the assumption of infinite induction Ld in direct current reactor(DCL). This paper focusing on the fact that Ld has bounded value in real circuit, examines operating characteristics by analysis of static state characteristics of current type inverter driven by voltage source and compares it with the operating characteristics of the circuit driven by current source.

  • PDF

Optimization of Magnetic Flux-path Design for Reduction of Shaft Voltage in IPM-Type BLDC Motor

  • Kim, Kyung-Tae;Hur, Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2187-2193
    • /
    • 2014
  • In this paper, we propose a method for suppressing shaft voltage by modifying the rotor shape and the permanent magnets in interior permanent magnet type high voltage motors. The shaft voltage, which adversely affects the bearing by occurring bearing current, is induced by parasitic components and the leakage flux in motor-driven systems as well as inherent linkage flux between main magnetic flux and shaft according to rotor configuration. Thus, shaft voltage should be analyzed and considered under inverter-driven and non-inverter-driven conditions because inherent linkage flux can analyze under non-inverter-driven condition. In this study, we designed re-arrangement magnet and re-structuring rotor to minimize the shaft voltage. In addition, we optimized the proposed models. The shaft voltage suppression effect of the designed model was validated experimentally and by comparative finite element analysis.

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.