• 제목/요약/키워드: Inverter Motor

검색결과 1,333건 처리시간 0.032초

인버터 특성을 고려한 견인전동기 설계와 제품동향 (Design of Traction Motor with consideration of Inverter Characteristics & Products Trend for Subway Train Application)

  • 김종구;권중록;김근웅;이정일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.459-463
    • /
    • 2001
  • Since recent inverters are formed IGBT VVVF inverter its switching speed has been increased relative to the conventional inverters and the motor design based on the switching surge voltage at the inverter output is very important factor. Therefore, motor and inverter should be designed to have the optimal characteristics by considering the mutually limited conditions. On this research the design technology characteristics for inverter driving traction moor is compared to the products in Korea and the analysis is performed. Thus, it is intend to re-estimate the technology level and introduce the products by HHI, which is driving on Seoul subway line 6 since December, 2000.

  • PDF

Rotor Fault Detection System for the Inverter Driven Induction Motor using Current Signals

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Choi, Chang-Ho
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.224-231
    • /
    • 2009
  • The induction motor rotor fault diagnosis system using current signals, which are measured using an axis-transformation method, is presented in this paper. In inverter-fed motor drives, unlike line-driven motor drives, the stator currents are rich in harmonics; therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, and encoder, etc. The proposed axis-transformation method with encoder and without encoder is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation is compared with the results obtained from fast Fourier transforms.

A Control Strategy of the Three-Phase Bridge-type ZVT Inverter for AC Motor Drives

  • Lee, Seong-Ryong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.529-534
    • /
    • 1998
  • In this paper, control strategies of the bridge-type ZVT inverter for AC motor drive application were discussed. The topology of the ZVT inverter is analyzed with a description of the control conditions based on the load current. And a new resonant control algorithm by using load current feedback and modified SVM algorithm for the proposed ZVT inverter is proposed in order to achieve the ZVT switching condition in full control range. The detailed computer simulation and experimental results represent that ZVT and ZCT operation for the main and auxiliary switch, respectively, was achieved.

  • PDF

저압인버터를 적용한 펌프모터의 고조파 분석 및 저감방안 (The diagnosis and appropriate reducing method on the harmonics for the induction motor installed inverter system)

  • 김기태;이은춘;이경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2056-2057
    • /
    • 2007
  • Recently we installed inverter system in $ind{\acute{u}}ction-m{\acute{o}}tor$ for the energy saving. But inverter system generates harmonics, and it causes a lot of issues. malfunction of meter, damage of instrument, overheating of motor. In this study, you can see how to deal with harmonics of inverter system by diagnosis of the power quality.

  • PDF

모터 파라미터 산포를 고려한 고속 운전에서의 속도제한 제어기 구현 (Implementation of Speed Limitation Controller Considering Motor Parameter Variation in High Speed Operation)

  • 김경훈;윤철;권우현
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1584-1590
    • /
    • 2017
  • This paper presents a implementation method of reliable speed limitation controller considering motor parameter variation in high speed operation. In spinning process of drum washing machine, speed increase has to be limited when unallowable imbalance mass is detected. Otherwise, severe noise and vibration can happen because noise and vibration are proportional to imbalance mass. To detect imbalance mass, d-axis current magnitude is used. However, we have to compensate for back-emf and power supply variation by means of detecting them because d-axis current is affected by both of them. On the other hand, we have to carefully estimate back-emf because back-emf is affected by stator resistance variation and inverter voltage error. Stator resistance variation can happen by manufacturing process for mass production or temperature variation in running. And there are inverter voltage errors between command voltage from micro-computer to inverter and real voltage from inverter to motor because of rising and falling time delay and turn-on resistance of power semiconductor switch. To solve this problem, we propose 2-step align current injection method which is to inject step-wise current right before starting. By this method, we can simply obtain stator resistance by ratio of voltage without inverter voltage error and current, and we can measure inverter voltage error. So we can obtain more exact model current, and then by simple calculation with compensation gain, we can estimate more accurate motor back-emf. We show that this method works well. It is verified through experiments.

3상 전원 조건의 모터 구동 인버터 내압 저감을 위한 공진 강압형 DC/DC 컨버터 (Resonant Step-Down DC/DC Converter to Reduce Voltage Stresses of Motor Driving Inverter under 3-phase AC Utility Line Condition)

  • 강경수;김상언;이준환;노정욱
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.391-398
    • /
    • 2014
  • This paper presents a resonant step-down DC/DC converter to reduce the voltage stresses of a 3-phase inverter module under the three-phase AC utility line condition. Under this condition, a conventional 3-phase inverter module suffers from high voltage stresses as a result of the high rectified DC link voltage; hence, a high-cost high-voltage-rating inverter module must be used. However, using the proposed converter, a low-cost low-voltage-rating inverter module may be adopted to drive the motor even under the 3-phase AC line condition. The proposed converter, which can be realized with small size inductor and low-voltage-rating semiconductor devices, operates at a high-efficiency mode because of the zero-current switching operations of all the semiconductor devices. The operational principles are explained and a design example is provided in the study. Experimental results demonstrate the validity of the proposed converter.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 II - 3-레그 타입의 경우 - (A Novel PWM Method for Three-Leg Two-Phase Inverter Fed Two-Phase Induction Motor)

  • 장도현
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.339-346
    • /
    • 2005
  • 본 논문에서는 3-레그 2상 인버터의 새로운 PWM방식을 제안하였다. 기존의 3-레그 인버터의 PWM방식은 전형적인 SVPWM 방식을 적용하여 PWM 방식이 복잡하다. 3-레그 2상 인버터를 "중성점이 있는 4-레그 인버터"의 등가회로라고 할 때 3-레그 인버터에서 형성되는 6개의 섹터는 4개의 섹터로 축소되며, 각 영역에서는 SYPWM 방식 대신 단순화된 정현파형 PWM방식을 적용할 수 있다. 각 레그의 스위치마다 스위칭 시간을 계산하는 스위칭 패턴을 제시하였다. 제안된 ,3-레그 인버터의 PWM방식에 대한 타당성을 확인하기 위해 모의 실험과 실험이 실행되었다.

선형화된 유동전동기의 특성 및 속도제어에 관한 연구 (A Study on Speed Control and Characteristics of I.M. Having Linear Transfer Function)

  • 윤병도;김대훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.337-340
    • /
    • 1988
  • This paper describes a fast response control of an inverter-fed induction Motor. The transfer function of the induction Motor controlled by this control method ie very similar to that of a separately exited dc motor. This paper presents the linear control method for the transfer function in the control of an inverter-fed induction motor, Acceding to this control, the response speed is correctly grasped faking the leakage inductances into account and the inverter-fed induction motor is controlled with fast response.

  • PDF

인버어터 구동 2상 유도 전동기의 새로운 구동 방식에 관한 연구 (Novel Driving System of 2-Phase Induction Motor Driven with Voltage Source Inverter)

  • Jang, Do-Hyun
    • 대한전기학회논문지
    • /
    • 제38권7호
    • /
    • pp.481-491
    • /
    • 1989
  • A compensation strategy for the phase-difference control method, which has been reported as a new driving method of a 2-phase inverter-fed induction motor, is proposed. The phase-difference control method extends the control range of the speed and eliminates the harmonic contents of the output voltage of the 2-phase inverter-fed induction motor. However, the phase-difference angle becomes narrower, motor efficiency deceases more and pulsating torque increases more. As the counterplan for these shortcomings of the phase-difference control method, a hybrid control method which combines the phase-difference control with the voltage control is proposed. The algorithm to realize a hybrid method is presented. As an example, a model composed of 5 regions has been analyzed by computer simulation in terms of motor performance and the results have been compared with experimental results.