• Title/Summary/Keyword: Inverter Filter

Search Result 529, Processing Time 0.028 seconds

A Fuzzy Self-Tuning PID Controller with a Derivative Filter for Power Control in Induction Heating Systems

  • Chakrabarti, Arijit;Chakraborty, Avijit;Sadhu, Pradip Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1577-1586
    • /
    • 2017
  • The Proportional-Integral-Derivative (PID) controller is still the most widespread control strategy in the industry. PID controllers have gained popularity due to their simplicity, better control performance and excellent robustness to uncertainties. This paper presents the optimal tuning of a PID controller for domestic induction heating systems with a series resonant inverter for controlling the induction heating power. The objective is to design a stable and superior control system by tuning the PID controller with a derivative filter (PIDF) through Fuzzy logic. The paper also compares the performance of the Fuzzy PIDF controller with that of a Ziegler-Nichols PID controller and a fine-tuned PID controller with a derivative filter. The system modeling and controllers are simulated in MATLAB/SIMULINK. The results obtained show the effectiveness and superiority of the proposed Fuzzy PID controller with a derivative filter.

A Small Signal Modeling of Three-level Neutral-Point-Clamped Inverter and Neutral-Point Voltage Oscillation Reduction (3레벨 NPC인버터의 소신호 모델링과 중성점 전압 진동 저감)

  • Cho, Ja-Hwi;Ku, Nam-Joon;Joung, Seok-Eon;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.407-414
    • /
    • 2014
  • This study proposes a control design for the grid output current and for reducing the neutral-point voltage oscillation through the small-signal modeling of the three-phase grid connected with a three-level neutral-point-clamped (NPC) inverter with LCL filter. The three-level NPC inverter presents an inherent problem: the neutral-point voltage fluctuation caused by the neutral-point current flowing in or out from the neutral point. The small signal modeling consists of averaging, dq0 transformation, perturbing, and linearizing steps performed on a three-phase grid connected to a three-level NPC inverter with LCL filter. The proposed method controls both the grid output and neutral-point currents at every switching period and reduces the neutral-point voltage oscillation. The validity of the proposed method is verified through simulation and experiment.

A Equivalent Circuit for Lossless 2-Port Using Inverter and Its Application (무 손실 2-포트 회로의 인버터를 사용한 등가회로 및 응용)

  • Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.761-770
    • /
    • 2008
  • Impedance or admittance inverter is a conceptual 2-port device frequently used in microwave filter design. In this paper, the equivalent circuit using inverter for general loss less 2-port circuit is presented. Our equivalent circuit can be directly and easily represented with z- or y-parameters compared with the conventional methods. Based on the representation, the derived results for various coupled lines such as parallel coupled line and anti-parallel coupled lines are compared ours. In addition, the results of other workers for improvement of the distortion in frequency response of microstrip coupled line filter are derived using our representation and compared. The proposed equivalent circuit shows the difference with conventional equivalent circuit so the conventional design method can not be applied to parallel coupled line filter with our representation. So in this paper the novel design method is proposed and we showed the method yields more accurate design results.

Reduction of the Unbalanced Three Phase Input Current by Variable Notch Filter in Active AC Electronic Load (가변 노치필터에 의한 능동형 AC 전자부하의 3상 전류 불평형 저감)

  • Kim, Do-Yun;Lee, Jung-Hyo;Lee, Yong-Seok;Jung, Doo-Yong;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.158-165
    • /
    • 2012
  • In this paper, the test bed using three-phase PWM converter connected with single phase inverter in series is set up to configure an active AC electric load. Since the two topologies, three-phase PWM converter and single-phase inverter, can be operated bidirectionally, the system not only re-generates surplus power to grid but also prevents power dissipation. However, the construction of system has a drawback. That is, ripple components two times of inverter operation frequency occur at DC-Link due to cascade connection, it can be cause of three phase unbalance Since the operational characteristic of the active AC electric load, the power frequency entered into the electric load can be varied, and the ripple of DC-Link is changed as well. In this paper, the three-phase PWM converter using a variable notch filter is proposed, and the reduction of three-phase current unbalance is presented. the validity of the proposed PWM converter using a variable notch filter is verified by the simulation and experimental results.

A design method for the bandpass filters with the consideration of inverter phase variation characteristics (주파수에 대한 인버터의 위상변화 특성을 고려한 대역통과 여파기 설계방법)

  • Ahn, Dal;Myoung, Soung-Ho;Kang, Hyun-Taek;Kim, Chul-Soo;Park, Jun-Seok;Lim, Jae-Bong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.5
    • /
    • pp.25-32
    • /
    • 2000
  • In this paper, we consider the effects on the bandpass filter characteristics due to the phase variation of the inverters with frequency, which introduces the deviations of the bandpass filter characteristics from the design goals. In order to resolve these kinds of problems, we proposed novel inverter configurations. And we derived the inverter formulas for the proposed inverter configuration. By employing the proposed inverter configuration and the derived formulas, bandpass filters are designed and simulated. In order to show the validity of the proposed design method, the simulation characteristics are compared with design results by conventional design procedures. Compared results show the compensation of the deviations of bandpass filter characteristics without any optimization or iterative design procedures and additional calculation efforts.

  • PDF

A New Design of Trisection Band-Pass Filter Based on Electromagnetic Simulation (EM 시뮬레이션을 기반으로 한 트라이섹션 대역 통과 여파기의 새로운 설계)

  • Kim, So-Su;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1086-1096
    • /
    • 2011
  • In this paper, we present the trisection band-pass filter with a transmission zero at 2.63 GHz, which has a center frequency of 2.44 GHz, relative bandwidth of 5 %, and return loss of 18 dB, based on a multi-port ElectroMagnetic simulation. The coupling matrix for the trisection filter is calculated and this filter is transformed into band-pass filter prototype through a lossless 2-port circuit transformation. The J-inverter values and slope parameters of each individual resonator are computed using an EM simulation Y-parameters of the filter with multi port. The dimensions of desired filter are determined by matching the computed J-inverter and susceptance slope parameters to those of the prototype band-pass filter. Undesired cross-couplings are found to occur which does not appear in the prototype trisection filter. To overcome the problem of undesired couplings, the filter was optimized to satisfy the same frequency response of prototype filter. The validity of the proposed design method was verified through the implementation of the designed and optimized filter.

Minimum DC-Link Filter in Three-phase PWM Voltage Source Inverter for Induction Motor Drive (유도 전동기 구동 시스템을 위한 PWM전압원 인버터 DC-링크 필터 설계)

  • Kim, Kwang-Seob;Suh, Bum-Seok;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.495-497
    • /
    • 1994
  • Given the constraint of the AC input power factor and the DC-link voltage and current ripple in voltage source inverter, minimizing the size and cost of the DC-link fitter components is very important. This paper presents a procedure for the selection of DC-link filler element values in a three-phase PWM voltage source inverter-fed induction motor drive system, which can not only satisfy the requirements for the system performance but also minimize the filter size.

  • PDF

A Study on the Three Phase Multi-PAM Inverter using the one-chip Microcomputer for UPS. (원칩 마이크로 컴퓨터를 이용한 UPS용 3상 다중 PAM 인버터에 관한 연구)

  • 김성백;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 1989
  • This paper discussed the Multi-PAM inverter for static power supply design. The controller part composed of one-chip microcomputer obtained control pattern simply. The configuration of termination part was composed of double bridge inverter and three-phase, three-winding transformer. The output waveforms using a controller and transformers synthesized the multi-PAM wave form by a voltage level of 22 steps per one-cycle. The output waveforms using the Low Pass Filter approximated to the sine wave.

  • PDF

A study on energy regeneration of power supply for DC electric traction system (직류전철용 전력공급 장치의 에너지희생에 관한 연구)

  • Bang Hyo-Jin;Jang Su-jin;Song Sang-Hun;Won Chung-Yuen;Kim Yong-Ki;Ahn yu-Bok
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.439-442
    • /
    • 2004
  • This paper described a dc power system, which can generate the excessive do power form do bus line to ac source in substation for traction system. The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation.

  • PDF

Isolation Amplifier Circuits for Sensing and Feedback of the Inverter DC-Link Voltage (인버터의 직류링크 전압 검출 및 궤환을 위한 절연앰프 회로)

  • Kim, Kyung-Seo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.522-529
    • /
    • 2014
  • This study proposes an isolation amplifier circuit for the sensing and feedback of inverter DC-link voltage, which is inevitable for the precise control of inverter output voltage. The isolation amplifier consists of a pulse-width modulator and a pulse transformer with dual secondary windings. The accuracy of the proposed circuit depends on the precise matching of filter parameters in dual secondary circuits. The influences of parameter inaccuracy on the amplifier performances are analyzed. A modified circuit is proposed to reduce the dependency on filter parameters. The validity of the proposed method is verified through simulation and experiment.