• 제목/요약/키워드: Inverse Gaussian distribution

검색결과 51건 처리시간 0.03초

A class of accelerated sequential procedures with applications to estimation problems for some distributions useful in reliability theory

  • Joshi, Neeraj;Bapat, Sudeep R.;Shukla, Ashish Kumar
    • Communications for Statistical Applications and Methods
    • /
    • 제28권5호
    • /
    • pp.563-582
    • /
    • 2021
  • This paper deals with developing a general class of accelerated sequential procedures and obtaining the associated second-order approximations for the expected sample size and 'regret' (difference between the risks of the proposed accelerated sequential procedure and the optimum fixed sample size procedure) function. We establish that the estimation problems based on various lifetime distributions can be tackled with the help of the proposed class of accelerated sequential procedures. Extensive simulation analysis is presented in support of the accuracy of our proposed methodology using the Pareto distribution and a real data set on carbon fibers is also analyzed to demonstrate the practical utility. We also provide the brief details of some other inferential problems which can be seen as the applications of the proposed class of accelerated sequential procedures.

Validation and selection of GCPs obtained from ERS SAR and the SRTM DEM: Application to SPOT DEM Construction

  • Jung, Hyung-Sup;Hong, Sang-Hoon;Won, Joong-Sun
    • 대한원격탐사학회지
    • /
    • 제24권5호
    • /
    • pp.483-496
    • /
    • 2008
  • Qualified ground control points (GCPs) are required to construct a digital elevation model (DEM) from a pushbroom stereo pair. An inverse geolocation algorithm for extracting GCPs from ERS SAR data and the SRTM DEM was recently developed. However, not all GCPs established by this method are accurate enough for direct application to the geometric correction of pushbroom images such as SPOT, IRS, etc, and thus a method for selecting and removing inaccurate points from the sets of GCPs is needed. In this study, we propose a method for evaluating GCP accuracy and winnowing sets of GCPs through orientation modeling of pushbroom image and validate performance of this method using SPOT stereo pair of Daejon City. It has been found that the statistical distribution of GCP positional errors is approximately Gaussian without bias, and that the residual errors estimated by orientation modeling have a linear relationship with the positional errors. Inaccurate GCPs have large positional errors and can be iteratively eliminated by thresholding the residual errors. Forty-one GCPs were initially extracted for the test, with mean the positional error values of 25.6m, 2.5m and -6.1m in the X-, Y- and Z-directions, respectively, and standard deviations of 62.4m, 37.6m and 15.0m. Twenty-one GCPs were eliminated by the proposed method, resulting in the standard deviations of the positional errors of the 20 final GCPs being reduced to 13.9m, 8.5m and 7.5m in the X-, Y- and Z-directions, respectively. Orientation modeling of the SPOT stereo pair was performed using the 20 GCPs, and the model was checked against 15 map-based points. The root mean square errors (RMSEs) of the model were 10.4m, 7.1m and 12.1m in X-, Y- and Z-directions, respectively. A SPOT DEM with a 20m ground resolution was successfully constructed using a automatic matching procedure.

보험위험 확률모형에서의 파산확률 (Ruin Probability on Insurance Risk Models)

  • 박현숙;최정규
    • 응용통계연구
    • /
    • 제24권4호
    • /
    • pp.575-586
    • /
    • 2011
  • 본 연구는 보험산업에서 관심을 갖는 파산확률의 근사적 추이를 살펴보기 위하여 크레임의 분포가 정규변동성 성질을 갖는 사례를 통하여 파산가능성의 추이를 살펴보고, 정확한 파산확률 유도에 결정적인 역할을 하는 계수를 추정하는 실증연구에 초점을 둔다. 추정된 결정계수와 보험위험 확률모형의 안전지수와의 연관성을 분석하여 파산확률의 추이를 진단하는 방법도 함께 진행된다.

지하 불균질 예측 향상을 위한 마르코프 체인 몬테 카를로 히스토리 매칭 기법 개발 (A Development of Markov Chain Monte Carlo History Matching Technique for Subsurface Characterization)

  • 정진아;박은규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권3호
    • /
    • pp.51-64
    • /
    • 2015
  • In the present study, we develop two history matching techniques based on Markov chain Monte Carlo method where radial basis function and Gaussian distribution generated by unconditional geostatistical simulation are employed as the random walk transition kernels. The Bayesian inverse methods for aquifer characterization as the developed models can be effectively applied to the condition even when the targeted information such as hydraulic conductivity is absent and there are transient hydraulic head records due to imposed stress at observation wells. The model which uses unconditional simulation as random walk transition kernel has advantage in that spatial statistics can be directly associated with the predictions. The model using radial basis function network shares the same advantages as the model with unconditional simulation, yet the radial basis function network based the model does not require external geostatistical techniques. Also, by employing radial basis function as transition kernel, multi-scale nested structures can be rigorously addressed. In the validations of the developed models, the overall predictabilities of both models are sound by showing high correlation coefficient between the reference and the predicted. In terms of the model performance, the model with radial basis function network has higher error reduction rate and computational efficiency than with unconditional geostatistical simulation.

베이지안 순서형 프로빗 준모수 회귀 모형 : 국민건강영양조사 2016 자료를 통한 흡연양태와 커피섭취 간의 관계 분석 (Bayesian ordinal probit semiparametric regression models: KNHANES 2016 data analysis of the relationship between smoking behavior and coffee intake)

  • 이다솜;이은지;조성일;최태련
    • 응용통계연구
    • /
    • 제33권1호
    • /
    • pp.25-46
    • /
    • 2020
  • 본 논문에서는 Bayesian spectral analysis regression (BSAR) 방법론을 이용한 베이지안 순서형 프로빗 준모수 회귀모형에 대해서 고찰한다. 순서형 프로빗 회귀모형은 순서가 있는 범주형 자료를 모형화하는 방법으로, 정규 분포의 분포함수의 역함수인 프로빗 연결함수를 이용해 각 범주의 확률과 설명변수을 연결함으로써 반응변수의 확률을 모형화한다. 베이지안 프로빗 회귀 모형은 정규 분포를 따르는 잠재변수를 도입함으로써 사후 분포 도출을 용이하게 하고, 절단점에 따라 나뉘어지는 잠재변수들의 값에 따라서 반응 변수들이 범주화된다. 본 논문에서는 이러한 잠재 변수 방법을 확장해 BSAR 방법론에 기반하여 단조증가/감소와 같은 형태제약을 반영할 수 있는 베이지안 이항형 및 순서형 프로빗 준모수 회귀모형에 대해 연구한다. 모의실험을 통하여 이항형 프로빗 준모수 회귀모형과 기존의 다른 모형들 간의 적합결과를 비교하고, 형태 제약에 따른 순서형 프로빗 준모수 회귀모형의 적합결과를 비교 분석하도록 한다. 아울러, 국민건강영양조사 제 7기 1차년도 (2016) 자료(Korean National Health and Nutrition Examination Survey (KNHANES), 2016)를 바탕으로, 본 논문에서 고찰한 이항형 및 순서형 프로빗 준모수 회귀모형을 적용하여, 흡연양태와 커피섭취 간의 관계에 대한 실증적 분석을 수행한다.

상수도관망 내 데이터 불확실성에 따른 절점 압력 예측 ANN 모델 수행 성능 비교 (Comparison of ANN model's prediction performance according to the level of data uncertainty in water distribution network)

  • 장혜운;정동휘;전상훈
    • 한국수자원학회논문집
    • /
    • 제55권spc1호
    • /
    • pp.1295-1303
    • /
    • 2022
  • 안정적인 수도 공급을 위한 상수도관망의 역할이 더욱 주목받음에 따라 비정상 상황에 대한 신속한 탐지와 적절한 대처 역시 중요시되고 있다. 장치에 의존한 탐지기법 등 기존의 방법론에는 한계가 존재하므로 데이터를 이용한 모델 기반의 방법이 개발되었다. 하지만 상수도관망 내 측정 데이터는 불확실성을 가져 실제 사용량과 다르다. 따라서 본 연구에서는 기계학습 방법의 하나인 인공신경망 모델을 이용하여 상수도관망 압력값을 예측함에 있어 데이터 불확실성의 영향을 조사한다. 정규분포를 따르는 임의의 값을 고려하여 데이터에 측정치 오류를 형성하고 측정치 오류 여부 및 종류에 따라 총 9가지 데이터를 인공신경망 모델을 통해 예측해 경향성을 비교한다. 분석을 통해 데이터 불확실성이 증가할수록 모델 성능이 감소하며, 출력데이터의 측정치 오류가 모델 성능에 미치는 정도가 더 큼을 확인하였다. 특히 입력데이터와 출력데이터의 측정 오차 크기가 동일한 경우 예측 정확도는 각각 72.25%, 38.61%로 큰 차이를 보였다. 따라서 ANN 모델 예측 성능 향상을 위해서는 입력 데이터보다 출력데이터인 주절점의 측정 오류 크기를 줄이는 것이 중요하다.

다중 자료 변환을 이용한 구성 자료의 지구통계학적 시뮬레이션 (Geostatistical Simulation of Compositional Data Using Multiple Data Transformations)

  • 박노욱
    • 한국지구과학회지
    • /
    • 제35권1호
    • /
    • pp.69-87
    • /
    • 2014
  • 이 논문에서는 구성 자료의 지구통계학적 시뮬레이션을 위해 다중 자료 변환 기반 조건부 시뮬레이션 틀을 제안하였다. 우선 일반적인 통계 기법의 적용이 가능하도록 구성 자료에 로그비 변환을 적용하였다. 다음 변환들로는 최소/최대 자기상관 인자 변환과 지시자 변환을 순차적으로 적용하였다. 독립적인 새로운 변수의 생성을 위해 최소/최대 자기상관 인자 변환을 적용하였으며, 적용 결과 개별 변수들의 독립적인 시뮬레이션이 가능해진다. 그리고 다중 가우시안 확률 모델을 따르지 않는 변수들의 비모수적 조건부 누적 확률 분포 모델링을 위해 지시자 변환을 적용하였다. 최종적으로는 적용한 변환 방법들의 역순으로 역 변환을 적용하였다. 간석지 표층 퇴적물 성분 자료를 대상으로 제안 시뮬레이션 기법의 적용 가능성을 예시하였다. 모든 시뮬레이션 결과들은 구성 자료의 제한 조건을 만족하면서 샘플 자료의 통계 특성을 잘 반영하였다. 구성 자료의 다수의 시뮬레이션 결과들을 이용한 표층 퇴적물 분류를 통해 기존 크리깅에서는 얻을 수 없는 분류 결과의 확률론적 평가가 가능하였다. 따라서 제안 시뮬레이션 틀은 다양한 구성 자료의 지구통계학적 시뮬레이션에 효과적으로 이용될 수 있을 것으로 기대된다.

DWT 부대역구조와 공간 윤곽선정보를 이용한 하이브리드 워터마킹 기술 (Hybrid Watermarking Technique using DWT Subband Structure and Spatial Edge Information)

  • 서영호;김동욱
    • 한국통신학회논문지
    • /
    • 제29권5C호
    • /
    • pp.706-715
    • /
    • 2004
  • 본 논문에서 제안되는 워터마크(Watermark) 삽입 알고리즘은 웨이블릿 변환 영역에서 구성되는 부대역간의 트리구조(Tree structure)와 공간 영역에서의 윤곽선 정보를 이용하여 워터마크를 삽입할 영역을 결정하고 삽입한다. 먼저 생성되는 고주파 성분의 부대역으로부터 저주파 부대역으로 중요 주파수 영역을 예측하게 되는데 웨이블릿 변환영역에서 구성된 트리구조에서 높은 주파수를 가지는 LHI 부대역을 4${\times}$4의 부행렬(Submatrix)로 나누고 행렬에 대한 평균과 이들에 의해 구성되는 블록 행렬(Block matrix)로부터 전체 평균 및 워터마크 삽입에 이용될 임계값을 얻는다. 또한 주파수 영역에서 구해진 에너지 특성에 대한 블록 행렬과 공간 영역에서 얻어진 영상의 윤곽선 정보에 의해 워터마크가 삽입될 위치인 키맵(Keymap)이 구해진다. 구해진 키맵에 따라서 LFSR(Linear feedback shift register)을 이용하여 발생된 무작위 순열(Random sequence)를 웨이블릿 도메인에서 이웃 웨이블릿 계수간의 관계를 이용하여 삽입한다. 최종적으로 역 웨이블릿 변환을 취함으로써 워터마크가 삽입된 영상을 생성한다. 제안된 워터마킹 알고리즘은 JPEG과 같은 압축과 Blurring, Sharpening, 그리고 가우시안(Gaussian) 잡음 등의 공격에 대해서도 기존의 방식에 비해 약 2㏈ 절도 높은 PSNR(Peak signal to noise ratio)를 보이면서 2%에서 8% 정도 높은 NR(Normalized correlation)를 가져서 좋은 특성을 나타냈다.

단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구 (A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2002
  • 블록을 사용한 부정형 전자선 조사면에서의 선량율(relative output factor, ROF)을 계산하는 전자선 알고리듬을 개발하고, 측정값과 계산값을 비교하여 알고리듬을 평가하였다. 전자선의 선량은 산란판, 전자선 cone 등 모든 요소를 고려한 1차선 부분과 블럭에 의한 2차선의 합으로 표시할 수 있다고 가정하였으며, 1차선은 가우스 분포를, 2차선은 거리역제곱 법칙만을 따른다고 가정하였다. 2차선 블럭 산란에 의한 각 분포는 고려하지 않았다. 이런 방법으로 전자선의 ROF를 유효 SSD, 1차선 분포 표준편차, 2차선 발생율 등 3가지의 인자만을 이용하여 선량율을 계산할 수 있는 단순한 방식을 고안하였다. 6, 9, 12, 16, 20 MeV의 전자선을 사용하여 이 모델을 검증하였다. 측정은 항상 개방 조사면의 선량 최대지점 깊이에서 실시하였으며 다양한 정사각형 치료면 측정으로 3개의 인자를 구할 수 있었다 직사각형 조사면과 부정형 조사면에 대하여 이 모델을 이용한 계산값과 측정값의 차이는 평균 1.0%이내였으며, 최대 2.1%를 넘지 않았다. 본 연구에서 개발한 알고리듬은 필요한 인자가 3개이면서 매 전자선 콘마다 5∼6회 측정으로 구할 수 있어서 임상 적용에 편리하며, 계산 결과가 정확하여 특이 오차를 보이는 유형에 관한 보완 연구를 수행하면 임상에 사용할 수 있음을 보였다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF