• 제목/요약/키워드: Invasive procedures

Search Result 399, Processing Time 0.026 seconds

Hemodynamic Evaluation of Acute Mitral Valve Insufficiency Model induced by Chordae Tendinae Rupture in Normal Dogs (개에서 건삭파열로 유발한 급성 이첨판 폐쇄부전 모델의 혈류역학적 평가)

  • Kim, Sehoon;Kim, Nam-Soo;Lee, Ki-Chang;Kim, Jong Min;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.367-370
    • /
    • 2014
  • The study was to observe hemodynamic alterations of cardiac function to design a model of canine mitral valve insufficiency (MVI) based on chordae tendinae rupture (CTR). Ten healthy beagles with normal heart function were used in this study. To measure hemodynamics, the patient monitor was equipped for invasive blood pressure and a Swan-Ganz catheter. Hemodynamic alterations were checked promptly during CTR procedures. MVI model was made by transection of the chordae tendinae with small arthroscopy hook knife through $5^{th}$ intercostal open chest. Color Doppler at the level of the mitral valve showed high-velocity regurgitant flow immediately after CTR at intraoperative echocardiography. In hemodynamic measurements, pulmonary capillary wedge pressure (PCWP) was significantly increased, while mean arterial pressure (MAP), venous pressure (VP), pulmonary arterial pressure (PAP), cardiac output (CO) and cardiac index (CI) were significantly decreased after CTR. It was known that the left atrium was overloaded by regurgitant volume from the left ventricle. In conclusion, the MVI model induced by CTR technique in this study should be used as suitable one for the effective research of canine mitral valve disease. Further study should be needed to measure the chronic alternation of mitral valve in the model.

Paraspinal Muscle Sparing versus Percutaneous Screw Fixation: A Prospective and Comparative Study for the Treatment of L5-S1 Spondylolisthesis

  • Jang, Kun-Soo;Kim, Heyun-Sung;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.3
    • /
    • pp.163-166
    • /
    • 2011
  • Objective : Both the paraspinal muscle sparing approach and percutaneous screw fixation are less traumatic procedures in comparison with the conventional midline approach. These techniques have been used with the goal of reducing muscle injury. The purpose of this study was to evaluate and to compare the safety and efficacy of the paraspinal muscle sparing technique and percutaneous screw fixation for the treatment of L5-S1 spondylolisthesis. Methods : Twenty patients who had undergone posterior lumbar interbody fusion (PLIF) at the L5-S1 segment for spondylolisthesis were prospectively studied. They were divided into two groups by screw fixation technique (Group I : paraspinal muscle sparing approach and Group II: percutaneous screw fixation). Clinical outcomes were assessed by Low Back Outcome Score (LBOS) and Visual Analogue Scale (VAS) for back and leg pain at different times after surgery. In addition, modified MacNab's grading criteria were used to assess subjective patients' outcomes 6 months after surgery. Postoperative midline surgical scarring, intraoperative blood loss, mean operation time, and procedure-related complications were analyzed. Results : Excellent or good results were observed in all patients in both groups 6 months after surgery. Patients in both groups showed marked improvement in terms of LBOSs all over time intervals. Postoperative midline surgical scarring and intraoperative blood loss were lower in Group II compared to Group I although these differences were not statistically significant. Low back pain (LBP) and leg pain in both groups also showed significant improvement when compared to preoperative scores. However, at 7 days and 1 month after surgery, patients in Group II had significantly better LBP scores compared to Group I. Conclusion : In terms of LBP during the early postoperative period, patients who underwent percutaneous screw fixation showed better results compared to ones who underwent screw fixation via the paraspinal muscle sparing approach. Our results indicate that the percutaneous screw fixation procedure is the preferable minimally invasive technique for reducing LBP associated with L5-S1 spondylolisthesis.

A Comparative Study of Endotracheal Aspirates and Protected Specimen Brush in the Quantitative Cultures of the Ventilator-Associated Pneumonia (기계호흡기 관련 폐렴환자의 정량적 배양에 있어서 Endotracheal Aspirates과 Protected Specimen Brush의 비교 관찰)

  • Roo, Kyoung-Ryeol;Kim, Min-Gu;Kim, Gi-Yang;Jung, Ho-Gyeong;Park, Young-Ho;Kang, Byeng-Sun;Kim, Ho-Chul;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.737-743
    • /
    • 1995
  • Background: Pneumonia is a frequent complication in patients undergoing mechanical ventilation, Quantitative culture of protected specimen brush(PSB) have shown satisfactory diagnostic accuracy for the diagnosis of ventilator-associated pneumonia. However PSB method is invasive, expensive, and require a bronchoscopic procedure. But endotracheal aspiration(EA) is simple and less expensive. The purpose of our study was to investigate the diagnosic value of EA quantitative cultures. Method: We studied 15 cases of ventilator-associated pneumonia(for >72h of mechanical ventilation) patients. Patients were divided into two diagnostic categories. Group I was the patients who were suspicious of clinical pneumonia, Group II was the patients for control. The obtained samples by EA and PSB were homogenized for quantitative culture with a calibrated loop method in all patients. Result: Using $10^3cfu/ml$, $10^5cfu/ml$ as threshold in quantitative culture of PSB, EA respectively, we found that EA quantitative cultures represented a relatively sentive(70%) and relatively specific (60%) method to diagnose the ventilator-associated pneumonia. Conclusion: Although EA quantitative cultures are less specific than PSB for diagnosing ventilator-associated pneumonia. EA quantitative cultures correlated with PSB quantitative culture in patients with clinical pneumonia and may be used to treat these patients when bronchoscopic procedures are not available.

  • PDF

Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading (상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.423-439
    • /
    • 2012
  • This case report described a technique utilizing a computer-aided design (CAD)/computer-aided machining (CAM) - guided surgical implant placement and prefabricated temporary fixed prosthesis for an immediately loaded restoration. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla received 8 implants in maxilla using CAD/CAM surgical templates. Prefabricated provisional maxillary implant supported fixed prosthesis were connected immediately after implant installation. Provisional prosthesis was evaluated for aesthetics, function during 6 months. Definitive implant supported fixed porcelain fused metal bridges were fabricated.

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Thoracic Sympathetic Ganglionectomy for Primary Hyperhidrosis (본태성 다한증의 흉부 교감신경절 절제술)

  • 김일현;김광택;이인성;김형묵;김학제
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.519-524
    • /
    • 1998
  • From January 1996 to December 1996, we performed 137 thoracic sympathetic ganglionectomies with VATs for primary hyperhidrosis in the department of thoracic and cardiovascular surgery at Anam hospital, Korea university medical center. There were 83 men and 54 women whose ages ranged from 13 to 63 years old(mean age: 25years). Of these patients, 128 patients had complained of palmar hyperhidrosis and 26 of facial hyperhidrosis. Thoracoscopic sympathetic ganglionectomies procedures included lower 1/3 Stellate ganglionectomies in 4 patients; lower 1/3 Stellate ganglionectomies and T2-sympathetic ganglionectomies in 18 patients; T2-sympathetic ganglionectomies in 86 patients; T2 and T3 sympathetic ganglionectomies in 10 patients; and T2, T3 and T4 sympathetic ganglionectomies in 19 patients. The mean operating time was 59 minutes(range: 25 to 162 minutes), and the mean hospital stay was 3.8 days(range: 2 to 8 days). Common complications were compensatory hyperhidrosis(109 patients) and causalgia(18 patients). At the end of the follow-up period(mean: 8 months) ninety-seven percent of the patients reported satisfactory results. Thoracic sympathetic ganglionectomy with VATs is an efficient, safe, and minimally invasive surgical procedure for primary hyperhidrosis.

  • PDF

Use of radiotherapy in patients with palliative double bypass for locally advanced pancreatic adenocarcinoma

  • Glinka, Juan;Diaz, Federico;Alva, Augusto;Mazza, Oscar;Claria, Rodrigo Sanchez;Ardiles, Victoria;Santibanes, Eduardo de;Pekolj, Juan;Santibanes, Martin de
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.210-217
    • /
    • 2018
  • Purpose: Pancreatic cancer (PC) has not changed overall survival in recent years despite therapeutic efforts. Surgery with curative intent has shown the best long-term oncological results. However, 80%-85% of patients with these tumors are unresectable at the time of diagnosis. In those patients, first therapeutic attempts are minimally invasive or surgical procedures to alleviate symptoms. The addition of radiotherapy (RT) to standard chemotherapy, ergo chemoradiation, in patients with locally advanced pancreatic cancer (LAPC) is still controversial. The study aims to compare outcomes in patients with a double bypass surgery due to LAPC treated or not with RT. Materials and Methods: A retrospective cohort study of patients with double bypass for LAPC were registered and divided into two groups: treated or not with postoperative RT. Baseline characteristics, postoperative complications, those related to RT and their relation to the main event (mortality) were compared. Results: Seventy-four patients were included. Surgical complications between the groups did not offer significant differences. Complications related to RT were mostly mild, and 86% of patients completed the treatment. Overall survival at 1 and 2 years for patients in the exposed group was 64% and 35% vs. 50% and 28% in the non-exposed group, respectively (p = 0.11; power 72%; hazard ratio = 0.53; 95% confidence interval, 0.24-1.18). Conclusion: We observed a tendency for survival improvement in patients with postoperative RT. However, we've not had enough power to demonstrate this difference, possibly due to the small sample size. It is indispensable to develop randomized and prospective trials to guide more specific treatment lines in this patients.

Clinical and Radiological Outcomes of Foraminal Decompression Using Unilateral Biportal Endoscopic Spine Surgery for Lumbar Foraminal Stenosis

  • Kim, Ju-Eun;Choi, Dae-Jung;Park, Eugene J.
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.439-447
    • /
    • 2018
  • Background: Since open Wiltse approach allows limited visualization for foraminal stenosis leading to an incomplete decompression, we report the short-term clinical and radiological results of unilateral biportal endoscopic foraminal decompression using $0^{\circ}$ or $30^{\circ}$ endoscopy with better visualization. Methods: We examined 31 patients that underwent surgery for neurological symptoms due to lumbar foraminal stenosis which was refractory to 6 weeks of conservative treatment. All 31 patients underwent unilateral biportal endoscopic far-lateral decompression (UBEFLD). One portal was used for viewing purpose, and the other was for surgical instruments. Unilateral foraminotomy was performed under guidance of $0^{\circ}$ or $30^{\circ}$ endoscopy. Clinical outcomes were analyzed using the modified Macnab criteria, Oswestry disability index, and visual analogue scale. Plain radiographs obtained preoperatively and 1 year postoperatively were compared to analyze the intervertebral angle (IVA), dynamic IVA, percentage of slip, dynamic percentage of slip (gap between the percentage of slip on flexion and extension views), slip angle, disc height index (DHI), and foraminal height index (FHI). Results: The IVA significantly increased from $6.24^{\circ}{\pm}4.27^{\circ}$ to $6.96^{\circ}{\pm}3.58^{\circ}$ at 1 year postoperatively (p = 0.306). The dynamic IVA slightly decreased from $6.27^{\circ}{\pm}3.12^{\circ}$ to $6.04^{\circ}{\pm}2.41^{\circ}$, but the difference was not statistically significant (p = 0.375). The percentage of slip was $3.41%{\pm}5.24%$ preoperatively and $6.01%{\pm}1.43%$ at 1-year follow-up (p = 0.227), showing no significant difference. The preoperative dynamic percentage of slip was $2.90%{\pm}3.37%$; at 1 year postoperatively, it was $3.13%{\pm}4.11%$ (p = 0.720), showing no significant difference. The DHI changed from $34.78%{\pm}9.54%$ preoperatively to $35.05%{\pm}8.83%$ postoperatively, which was not statistically significant (p = 0.837). In addition, the FHI slightly decreased from $55.15%{\pm}9.45%$ preoperatively to $54.56%{\pm}9.86%$ postoperatively, but the results were not statistically significant (p = 0.705). Conclusions: UBEFLD using endoscopy showed a satisfactory clinical outcome after 1-year follow-up and did not induce postoperative segmental spinal instability. It could be a feasible alternative to conventional open decompression or fusion surgery for lumbar foraminal stenosis.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.