• Title/Summary/Keyword: Internal leakage

Search Result 331, Processing Time 0.037 seconds

Improved Integrated Monitoring System Design and Construction (개선된 통합모니터링 시스템 설계 및 구축)

  • Jeon, Byung-Jin;Yoon, Deok-Byeong;Shin, Seung-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.1
    • /
    • pp.25-33
    • /
    • 2017
  • In order to prevent information leakage, companies are monitoring the information leakage by internal staff by building individual security system and integrated monitoring system of firewall and DLP function. Especially, many log data of the integrated monitoring system cause time and money, and it is difficult to detect information leak of fast malicious personnel due to system slowdown. It is necessary to speed up the system by digitizing large log data for each day and person for fast information leakage detection and there is a need to develop and manage a continuous monitoring program for the information leakage indications personnel. Therefore, we propose an improved integrated monitoring system using log data by date and individual data.

Countermeasure for Preventing a Secondary Damage of Information Leakage using Financial ISAC (금융 ISAC을 활용한 정보유출 2차피해 방지 방안)

  • Jeong, Gi Seog
    • Convergence Security Journal
    • /
    • v.14 no.5
    • /
    • pp.31-36
    • /
    • 2014
  • As security management center of financial area, financial ISAC monitors financial corporations and provides security services. Financial ISAC minimizes damage by responding quickly to external attack such as hacking, virus but it is poor at handling internal attack. For the efficient management and stable operation of information source, also to respond jointly to online hacking, the necessity of information sharing system increases day by day in and outside country. This paper proposes financial ISAC that can prevent a secondary damage of leakage information as well as providing security services. The proposed financial ISAC provides new password to financial corporation in which the same ID and password as leakage information are used and in case of financial information leakage it warns customers against phishing etc.

Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer (십이지장 궤양 천공 단순 봉합수술 후 완전 피막형 자가확장 금속 스텐트 삽입술로 치료된 봉합 부위 누출)

  • Yoo, Young Jin;Lee, Yong Kang;Lee, Joong Ho;Lee, Hyung Soon
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.262-266
    • /
    • 2018
  • Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.

Wind induced internal pressure overshoot in buildings with opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • v.16 no.1
    • /
    • pp.1-23
    • /
    • 2013
  • The wind-induced transient response of internal pressure following the creation of a sudden dominant opening during the occurrence of high external pressure, in low-rise residential and industrial buildings was numerically investigated. The values of the ill-defined parameters namely the flow contraction coefficient, loss coefficient and the effective slug length were calibrated by matching the analytical response with the computational fluid dynamics predictions. The effect of a sudden i.e., "instantaneously created" windward opening in the Texas Technical University (TTU) test building envelope was studied for two different envelope flexibility-leakage combinations namely: (1) a quasi-statically flexible and non-porous envelope and (2) a quasi-statically flexible and porous envelope. The responses forced by creating the openings at different time leads/lags with respect to the occurrence of the peak external pressure showed that for cases where the openings are created in close temporal proximity to the peak pressure, the transient overshoot values of internal pressure could be higher than the peak values of internal pressure in the pre-sequent or subsequent resonant response. In addition, the influence of time taken for opening creation on the level of overshoot was also investigated for the TTU building for the two different envelope characteristics. Non-dimensional overshoot factors are presented for a variety of cavity volume-opening area combinations for (1) buildings with rigid/quasi-statically flexible non-porous envelope, and (2) buildings with rigid/quasi-statically flexible and porous envelope (representing most low rise residential and industrial buildings). While the factors appear slightly on the high side due to conservative assumptions made in the analysis, a careful consideration regarding the implication of the timing and magnitude of such overshoots during strong gusts, in relation to the steady state internal pressure response in cyclonic regions, is warranted.

A study on the performance and internal flow of inline Francis turbine

  • Chen, Chengcheng;Inagaki, Morihito;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1225-1231
    • /
    • 2014
  • This paper presents the performance characteristic of a Francis hydro turbine with an inline casing. This turbine is designed for city water supply system. Due to large changes in ground elevation with high points and low points, some systems may experience larger-than-normal required pressures in areas with low ground elevations. One way to dissipate these excess pressures is by the use of an inline-turbine instead of an inline-pressure reducing valve. For best applicability and minimal space consumption, the turbine is designed with an inline casing instead of the common spiral casing. As a characteristic of inline casing, the flow accesses to the runner in the radial direction, showing a low efficiency. The installation of vanes improves the internal flow and gives the positive encouragement to the output power. For the power transmission to the outside of the turbine casing from the runner axis, a belt passage is designed in the inline casing, as its influence, the region after the belt passage shows a relatively low output power. The clearance gap in the runner side space is considered, in which a small volume of flow is contracted into the clearance gap, forming the leakage flow. The leakage flow leads to a decrease in the efficiency.

A USB DLP Scheme for Preventing Loss of Internal Confidential Files (내부 기밀파일 유출 방지를 위한 USB DLP 기법)

  • Shin, Gyu Jin;Jung, Gu Hyun;Yang, Dong Min;Lee, Bong Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2333-2340
    • /
    • 2017
  • Recently industry is suffering severe losses of important internal information, and most of the leaks result from the insiders. Thus, various technological counter measures are being studied in order to protect private organization information. In this paper, among various internal information leakage path protection mechanisms, we propose a technique for preventing files which are defined as confidential from being copied or moved through USB. The implemented confidential file loss prevention system is composed of both signature insert manager and confidential file detect manager. The signature insert manager allows a system administrator to insert a special pattern specifying a classified confidential file, while the confidential file detect manager protects confidential file leakage when a user attempts to move or copy a confidential file to the USB memory. This results would be contributed to reducing the damage caused by leakage of confidential files outside of the company via USB.

Ultra-Structures And $^{14}C$-Mannitol Transport Study of Human Nasal Epithelial Cells Using ALI Culture Technique (ALI 배양법 이용한 비강 점막 상피세포의 미세구조와 $^{14}C$-mannitol 투과도)

  • Kwak, Kyung-Rok;Hwang, Jee-Yoon;Lee, Ji-Seok;Park, Hye-Kyung;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew;Kim, Yoo-Sun;Roh, Hwan-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.205-212
    • /
    • 2001
  • Background : The information on nasal transport and the metabolism of peptides have been obtained from pharmacokinetic investigations in experimental animals. However, there are no transport and metabolic studies of human nasal epithelial cells. In this study, the permeability characteristics and the metabolic properties of in vitro human nasal cell monolayers were investigated. Material and Methods : Normal human inferior nasal conchal tissue samples were obtained from patients undergoing endoscopic nasal cavitary surgery. The specimens were cultured in a transwell using an air-liquid Interface (ALI) culture, and the transepithelial electrical resistance (TEER) value of the blank filter and confluent cell monolayers were measured. To determine the % leakage of mannitol, $4{\mu}mol%$ $^{14}C$-labelled mannitol was added and the % leakage was measured every 10 minute for 1 hour. Result : Human nasal epithelial cells in the primary culture grew to a confluent monolayer within 7 days and expressed microvilli. The tight junction between the cells was confirmed by transmission electron microscopy. The TEER value of the blank filter, fifth day and seventh day reached $108.5\;ohm.cm^2$, $141\;ohm.cm^2$ and $177.5\;ohm.cm^2$, respectively. Transcellular % leakage of the $^{14}$-mannitol at 10, 20, 30, 40, 50 and 60 minutes was $35.67{\pm}5.43$, $34.42{\pm}5.60$, $32.75{\pm}5.71$, $31.76{\pm}4.22$, $30.96{\pm}3.49$ and $29.60{\pm}3.68\;%$, respectively. Conclusion : The human nasal epithelial monolayer using ALI culture techniques is suitable for a transcellular permeability study. The data suggests that human nasal epithelial cells In an ALI culture technique shows some promise for a nasal transport and metabolism study.

  • PDF

Log Analysis Method of Separate Security Solution using Single Data Leakage Scenario (단일 정보유출 시나리오를 이용한 개별 보안솔루션 로그 분석 방법)

  • Park, Jang-Su;Lee, Im-Yeong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • According to recent statistics published by the National Industrial Security Center, former and current employees are responsible for 80.4% of companies' technology leakages, and employees of cooperative firms are responsible for another 9.6%. This means that 90% of technology leakages are intentionally or mistakenly caused by insiders. In a recent incident, a credit card company leaked private information, and the person responsible was an employee of a cooperative firm. These types of incidents have an adverse effect not only on a company's assets but also on its reputation. Therefore, most institutions implement various security solutions to prevent information from being leaked. However, security solutions are difficult to analyze and distinguish from one another because their logs are independently operated and managed. A large number of logs are created from various security solutions. This thesis investigates how to prevent internal data leakage by setting up individual scenarios for each security solution, analyzing each scenario's logs, and applying a monitoring system to each scenario.

Study on the Anti-inflammatory, Analgesic and Anti-thrombotic Effects of Shintongchugeotang in the Experimental Animals (신통축어탕(身痛逐瘀湯)의 항염(抗炎), 진통(鎭痛) 및 항열전효과(抗血栓效果)에 관(關)한 연구(硏究))

  • Liu, Ji-Yong;Lee, Gi-Sang;Moon, Byung-Soon
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.69-85
    • /
    • 1997
  • This study was designed to elucidate the anti-inflammatory, cardiovascular, anti-thrombotic and analgesic effects of Shintongchugeotang. The anti-inflammatory effect was measured by the method of carragenin induced edema, protein leakage test using CMC-pouch, and the analgesic effect was measured by the acetic acid method and hot plate method, and the effect of Shintongchugeotang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anti-coagurative effect of Shintongchugeotang. The result was as follows : 1. After the administration of Shintongchugeotang extract, Carragenin induced edema and CMC-pouch protein leakage were significantly decreased. 2. The slight analgesic effect of Shintongchugeotang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time. 3. The drug increased the auricular blood flow in rabbit. 4. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 5. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 6. The drug inhibited the platelet aggregation in rat. 7. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable.

  • PDF