Study on the propagation mechanism of stress wave in underground mining

  • Liu, Fei;Li, Lianghui
    • Computers and Concrete
    • /
    • 제25권2호
    • /
    • pp.145-154
    • /
    • 2020
  • For the influence of the propagation law of stress wave at the coal-rock interface during the pre-blasting of the top coal in top coal mining, the ANSYS-LS/DYNA fluid-solid coupling algorithm was used to numerical calculation and the life-death element method was used to simulate the propagation of explosion cracks. The equation of the crushing zone and the fracturing zone were derived. The results were calculated and showed that the crushing radius is 14.6 cm and the fracturing radius is 35.8 cm. With the increase of the angles between the borehole and the coal-rock interface, the vibration velocity of the coal particles and the rock particles at the interface decreases gradually, and the transmission coefficient of the stress wave from the coal mass into the rock mass decreases gradually. When the angle between the borehole and the coal-rock interface is 0°, the overall crushing degree is about 11% and up to the largest. With the increase of the distance from the charge to the coal-rock interface, the stress wave transmission coefficient and the crushing degree of the coal-rock are gradually decreased. At the distance of 50 cm, the crushing degree of the coal-rock reached the maximum of approximately 12.3%.

열분석 방법을 이용한 AISI 5160스프링강의 용접시 Heat Affected Zone에서의 결합규명과 수소취성에 관한 연구 (A study on the identification of the weld defects and hydrogen embrittlement in heat affected zone of AISI 5160 spring steel using thermal analysis technique)

  • 김민태;이재영
    • Journal of Welding and Joining
    • /
    • 제5권1호
    • /
    • pp.34-41
    • /
    • 1987
  • To explore the possible application of thermal analysis technique as a probe for finding weld defects, Hydrogen trapping phenomena in Heat Affected Zone (HAZ) of the AISI 5160 spring steel were investigated. HAZ was divided into five parts, which were used as thermal analysis specimens. Two types of trap sites were found in HAZ, ferrite/cementin interface and microvoid. The thermal analysis peak due to the ferrite/cementite interface increased its height toward the weld deposit. The thermal analysis peak due to the microvoid was the highest where the grain size was the smallest. The correspondence between the cold cracking and hydrogen trap nature is also discussed.

  • PDF

전단시험 중 모래입자의 변형에 관한 연구 (Study on the Evolution of Sand Structure during Shearing)

  • 이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.289-296
    • /
    • 2000
  • This paper summarizes the results of a study which has quantified the evolution of the structure of sands adjacent to geomembranes of varying roughness at different stages of shearing. The results show that the structure evolution, and hence shear mechanisms for rounded uniform sands adjacent to geomembranes, are directly influenced by the surface roughness of the geomembranes. For smooth geomembranes, the shear mechanism predominantly involves sliding of sand particles and only affects the sand structure within two particle diameters of the geomembrane. For slightly textured geomembranes, the effects of interlocking and dilation of sand particles extends the zone of evolution to four particles diameters from the interface. For moderately/heavily textured geomembranes, the interlocking and dilation of sand particles is fully developed and results in large dilation in the interfacial zone, which extends up to six particle diameters from the interface. By understanding how the structure of the sand adjacent to geomembranes of different roughness changes during shearing, it may be possible to identify alternative geomembrane roughening procedures and patterns that can lead to more efficient interface designs.

  • PDF

스마트 팩토리 디지털 트윈(Digital Twin)을 위한 IIoT 통신 기반 ZMP(Zone Master Platform) 설계 (A Design on The Zone Master Platform based on IIoT communication for Smart Factory Digital Twin)

  • 박선희;배종환
    • 사물인터넷융복합논문지
    • /
    • 제6권4호
    • /
    • pp.81-87
    • /
    • 2020
  • 본 논문은 스마트 팩토리(Smart Factory) 디지털 트윈(Digital Twin) 구축을 위해서 다양한 산업용 센서(IoT/비 IoT)로부터 센서데이터를 획득하기 위한 표준 노드(Node)를 생성하고 그룹별/공정별 존(Zone)을 연동하여 상호호환적인 데이터의 교환 기능을 제공함으로써 데이터의 안정성을 확보하고 스마트 팩토리의 디지털 트윈(Digital Twin)을 위한 효과적인 존 마스터(Zone Master) 플랫폼 구축 방안을 제시하였다. 존 마스터(Zone Master) 플랫폼의 Process는 독립된 시스템 간의 센서 객체 및 센서 상호작용이 어떻게 수행하는지를 정의해 주기 위한 인터페이스 명세를 포함하고 있으며 고유의 데이터 교환 규칙에 대한 개별 정책들을 수행하고 있다. 존 마스터 플랫폼 프로세서의 실행 통제를 위한 인터페이스는 시스템관리, 자료교환의 협상(publish-subscribe)을 위한 선언 관리, 센서 객체의 등록 및 상태 정보를 통신하기 위한 객체 관리, 속성 소유권 공유를 위한 소유권 관리, 데이터 동기화를 위한 시간 관리, 데이터 교환에 대한 Route 정보를 위한 자료 분배 관리를 제공한다.

엔진밸브 시트 표면의 오버레이층 특성에 미치는 용접법의 영향 (Effect of the Welding Methods on the Characteristics of Overlaying Seat-surfaces of Engine Valves)

  • 이병영;최병길
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.517-524
    • /
    • 2002
  • An overlaying of the seating surfaces of engine valves by OAW, GTAW or PTA weldings are common practice. The OAW method of a lower torch energy density compared to GTAW and PTA methods produces smoother deposits but the pain size at the vicinity of the interface is increased remarkably up to $30~50{\mu\textrm{m}}$ (that of base metal is about $10\mu\textrm{m}$). It's grain coarsening and the solute dilution are related to the decarburizing during OAW could be minimized by reducing the preheating temperature and by maintaining the carbide precipitates in base metal prior to welding. The formation of columnar structures and carbide precipitation zone in the vicinity of the GTAW welded interface, because of the high heat concentration, causes weakened zone on the valve seat face. The width of the reaction boundary zone is about $50\mu\textrm{m}$ for PTA and GTAW overlaying, and about $150\mu\textrm{m}$ for OAW welding. The smaller width of the reaction boundary zone is the less the solute-dilution rate. Thereby PTA welding may be recommended for overlaying of the seating surfaces.

SM45C 중실축의 마찰용접 기계적 특성에 관한 연구 (A Study on the Mechanical Properties of the Friction Welding with Solid Shaft of SM45C)

  • 구건섭
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.932-937
    • /
    • 2012
  • In the presented study, SM45C carbon steel parts were joined by friction welding. The welding process was carried out under optimized conditions using statistical approach. The study of SM45C is conducted with various combinations of process parameters. Parameter optimization, microstructure and mechanical property correlation are the major contribution of the study. The welded joints were produced by varying spindle revolution speed, friction pressure, upset pressure and burn-off length. Tension tests were applied to welded parts to obtain the strength of the joints. Fracturs properties were additionally obtained experimentally under fluctuated tensile loads. Microstructures using microphotographs were examined in the weld interface and weld region and heat affected zone and base metal and flash zone of welded parts. Finally, Hardness variations in welding zone and base metal were also obtained. Through these tests, the optimum conditions of parameters for ${\phi}20$ SM45C in friction welding were obtained when the friction spindle revolution was 1,950 rpm, the friction pressures was 30 MPs, upset pressures was 50 MPs.

직접 에너지 적층방식으로 제조된 V과 17-4PH 스테인리스강 이종재료의 접합계면 분석 (Joint Interface Observation of V and 17-4PH Stainless Steel Dissimilar Materials Manufactured by Direct Energy Deposition)

  • 이세환;김호범;김정한
    • 한국분말재료학회지
    • /
    • 제29권1호
    • /
    • pp.8-13
    • /
    • 2022
  • In this study, we have prepared a Ti-6Al-4V/V/17-4 PH composite structure via a direct energy deposition process, and analyzed the interfaces using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The joint interfaces comprise two zones, one being a mixed zone in which V and 17-4PH are partially mixed and another being a fusion zone in the 17-4PH region which consists of Fe+FeV. It is observed that the power of the laser used in the deposition process affects the thickness of the mixed zone. When a 210 W laser is used, the thickness of the mixed zone is wider than that obtained using a 150 W laser, and the interface resembles a serrated shape. Moreover, irrespective of the laser power used, the expected σ phase is found to be absent in the V/17-4 PH stainless steel joint; however, many VN precipitates are observed.

Microstructural observations of shear zones at cohesive soil-steel interfaces under large shear displacements

  • Mamen, Belgacem;Hammoud, Farid
    • Geomechanics and Engineering
    • /
    • 제25권4호
    • /
    • pp.275-282
    • /
    • 2021
  • Failure mechanism which can affect geotechnical infrastructures (shallow foundations, retaining walls, and piles) constitutes one of the most encountered problems during the design process. In this respect, the shear behavior of interfaces between grained soils and solid building materials, as well as those between cohesive soils should be investigated. Therefore, a range of ring shear tests with different cohesive soils and stainless-steel interfaces have been carried out through the Bromhead apparatus that allows simulating large displacements along a failure surface. The effects of steel rings roughness and soil type on the residual friction coefficient and the shear zone features (structure, thickness, and texture orientation angle) have been investigated using the Scanning Electron Microscopy. The obtained results indicate that the residual friction coefficient and the structural characteristics of the shear zone vary according to the surface roughness and the soil type. Scanning electron microscopy reveals that the particles inside the shear zone tend to be re-oriented. Also, the shear failure mechanism can be identified along with the interface, within the soil, or simultaneously at the interface and within the soil specimen.

Evaluation on the Mechanical Performance of Low-Quality Recycled Aggregate Through Interface Enhancement Between Cement Matrix and Coarse Aggregate by Surface Modification Technology

  • Choi, Heesup;Choi, Hyeonggil;Lim, Myungkwan;Inoue, Masumi;Kitagaki, Ryoma;Noguchi, Takafumi
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.87-97
    • /
    • 2016
  • In this study, a quantitative review was performed on the mechanical performance, permeation resistance of concrete, and durability of surface-modified coarse aggregates (SMCA) produced using low-quality recycled coarse aggregates, the surface of which was modified using a fine inorganic powder. The shear bond strength was first measured experimentally and the interface between the SMCA and the cement matrix was observed with field-emission scanning electron microscopy. The results showed that a reinforcement of the interfacial transition zone (ITZ), a weak part of the concrete, by coating the surface of the original coarse aggregate with surface-modification material, can help suppress the occurrence of microcracks and improve the mechanical performance of the aggregate. Also, the use of low-quality recycled coarse aggregates, the surfaces of which were modified using inorganic materials, resulted in improved strength, permeability, and durability of concrete. These results are thought to be due to the enhanced adhesion between the recycled coarse aggregates and the cement matrix, which resulted from the improved ITZ in the interface between a coarse aggregate and the cement matrix.

대형 터빈발전기 고정자 권선의 미세구조 분석 (Microstructure Analysis of Large Turbine Generator Stator Insulations)

  • 김희동;주영호;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1452-1454
    • /
    • 2002
  • Large turbine generator(rated 22kV) has failed in the stator winding area during normal operation. The capacitance and tan${\delta}$ were measured by Schering bridge in the zone 1, 2 and zone 3-6 stator windings. The capacitance and tan${\delta}$ in the zone 1, 2 of stator winding were higher than those of zone 3-6 in the stator winding. Experiments on microstructure property were conducted in the zone 1, 2 and zone 3-6 insulations, which were drawn out from stator windings of the large turbine generator. Microstructure analysis was characterized using scanning electron microscope(SEM). SEM results indicated that several isolated delaminations occurred at the interface of mica/epoxy insulations. Both thermal and mechanical aging cause the delamination.

  • PDF