• Title/Summary/Keyword: Interface shear strength

Search Result 492, Processing Time 0.024 seconds

Effects of Hybrid Coat on shear bond strength of five cements: an in-vitro study

  • Guo, Yue;Zhou, Hou-De;Feng, Yun-Zhi
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.447-452
    • /
    • 2017
  • PURPOSE. To evaluate the sealing performance of Hybrid Coat and its influence on the shear bond strength of five dentin surface cements. MATERIALS AND METHODS. Six premolars were pretreated to expose the dentin surface prior to the application of Hybrid Coat. The microscopic characteristics of the dentinal surfaces were examined with scanning electron microscopy (SEM). Then, 40 premolars were sectioned longitudinally, and 80 semi-sections were divided into a control group (untreated) and a study group (treated by Hybrid Coat). Alloy restoration was bonded to the teeth specimen using five different cements. Shear bond strength was measured by the universal testing machine. The fracture patterns and the adhesive interface were observed using a stereomicroscope. RESULTS. SEM revealed that the lumens of dentinal tubules were completely occluded by Hybrid Coat. The Hybrid Coat significantly improved the shear bond strength of resin-modified glass ionomer cement (RMGIC) and resin cement (RC) but weakened the performance of zinc phosphate cement (ZPC), zinc polycarboxylate cement (ZPCC) and glass ionomer cement (GIC). CONCLUSION. Hybrid Coat is an effective dentinal tubule sealant, and therefore its combined use with resin or resin-modified glass ionomer cements can be applied for the prostheses attachment purpose.

Shear behavior of reinforced HPC beams made of a low cement content without shear reinforcements

  • Tang, Chao-Wei;Chen, Yu-Ping;Chen, How-Ji;Huang, Chung-Ho;Liu, Tsang-Hao
    • Computers and Concrete
    • /
    • v.11 no.1
    • /
    • pp.21-37
    • /
    • 2013
  • High-performance concrete (HPC) usually has higher paste and lower coarse aggregate volumes than normal concrete. The lower aggregate content of HPC can affect the shear capacity of concrete members due to the formation of smooth fractured surfaces and the subsequent development of weak interface shear transfer. Therefore, an experimental investigation was conducted to study the shear strength and cracking behavior of full-scale reinforced beams made with low-cement-content high-performance concrete (LcHPC) as well as conventional HPC. A total of fourteen flexural reinforced concrete (RC) beams without shear reinforcements were tested under a two-point load until shear failure occurred. The primary design variables included the cement content, the shear span to effective depth ratio (a/d), and the tensile steel ratio (${\rho}_w$). The results indicate that LcHPC beams show comparable behaviors in crack and ultimate shear strength as compared with conventional HPC beams. Overall, the shear strength of LcHPC beams was found to be larger than that of corresponding HPC beams, particularly for an a/d value of 1.5. In addition, the crack and ultimate shear strength increased as a/d decreased or ${\rho}_w$ increased for both LcHPC beams and HPC beams. This investigation established that LcHPC is recommendable for structural concrete applications.

A Study on the Properties in Friction Weldability of Ni-Cr-Mo and SM45C (Ni-Cr-Mo과 SM45C의 마찰용접특성(摩擦熔接特性)에 관한 연구(硏究))

  • Lim, Hyung-Taek;Min, Taeg-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.29-36
    • /
    • 2007
  • The present study examined the mechanical properties of the friction welding of Ni-Cr-Mo to SM45C. Friction welding was conducted at welding conditions of 2,000 rpm, friction pressure of 100MPa, friction time of 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 seconds, upset pressure of 150MPa, and upset time of 3.0 seconds. When the friction time was 1.6 seconds, the maximum tensile strength of the friction weld happened to be 1,020MPa, which is 120% of the base material's tensile strength(850MPa). At the same condition, the maximum shear strength was 438MPa, which is equivalent to 103% of the base material's shear strength(425MPa). At the same condition, the maximum vickers hardness was Hv490 at Ni-Cr-Mo nearby weld interface, which is higher Hv40 than condition of the friction time 0.8 seconds, and the maximum vickers hardness was Hv305 from weld interface of SM45C, which is higher Hv12 than condition of the friction time 0.8 seconds. The results of microstructure analysis show that the structures of two base materials have fined and rearranged along a column due to heating and axial force during friction, which has affected in raising hardness and tensile strength.

Evaluation of Slant Shear Strength of Recycled Asphalt Mixture with Different Tack Coat Applications (Tack Coat 使用條件에 따른 再活用 아스팔트 混合物의 附着剪斷 性能評價)

  • 김낙석
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.32-41
    • /
    • 2001
  • Bond shear strengths of recycled asphalt concrete were evaluated under different tack coat applications. Regardless of the new and old mixtures, the bond shear strengths at $30^{\circ}C$ were increased by 10-20% than those at 1$0^{\circ}C$. The bond shear strengths of recycled asphalt concrete without tack coat showed very low ones. These are the main reasons for the frequent longitudinal interface crack in the field. The effect of tack coat curing time on bond shear strengths was inferior to the tack coat construction temperature.

  • PDF

Flexural Strength Evaluation of Steel Plate Concrete Shear wall subject to Monotonic Loading (단조하중을 받는 SC 전단벽의 휨강도 평가)

  • Kwon, Min-Ho;Kim, Jin-Sup;Seo, Hyun-Su;Lim, Jeong-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.9-14
    • /
    • 2013
  • In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.

Back analysis on shear failure of compacted soil liner in composite liner system (역해석을 통한 복합차수시스템의 점토차수재 사면파괴 사례 연구)

  • Lee, Chul-Ho;Min, Sun-Hong;Choi, Hang-Seok;Stark, Timothy D.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1315-1323
    • /
    • 2010
  • This paper deals with a case study on a unique slope failure in a liner system of a municipal solid waste containment facility during construction because the sliding interface is not the geomembrane/compacted low permeability soil liner (LPSL) but a soil/soil interface within the LPSL. From the case study, it is concluded that compaction of the LPSL should ensure that each lift is kneaded into the lower lift so a weak interface is not created in the LPSL, and the LPSL moisture content should be controlled so it does not exceed the specified value, .e.g., 3% - 4% wet of optimum, because it can lead to a weak interface in the LPSL. In addition, drainage materials should be placed over the geomembrane from the slope toe to the top to reduce the shear stresses applied to the weakest interface, and equipment should not move laterally across the slope if it is unsupported but along the slope while placing the cover soil from bottom to top.

  • PDF

Investigation of rate dependent shear bond properties of concrete masonry mortar joints under high-rate loading

  • John E. Hatfield;Genevieve L. Pezzola;John M. Hoemann;James S. Davidson
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.519-533
    • /
    • 2024
  • Many materials including cementitious concrete-type materials undergo material property changes during high-rate loading. There is a wealth of research regarding this phenomenon for concrete in compression and tension. However, there is minimal knowledge about how mortar material used in concrete masonry unit (CMU) construction behaves in high-rate shear loading. A series of experiments was conducted to examine the bond strength of mortar bonded to CMU units under high-rate shear loading. A novel experimental setup using a shock tube and dynamic ram were used to load specially constructed shear triplets in a double lap shear configuration with no pre-compression. The Finite Element Method was leveraged in conjunction with data from the experimental investigation to establish if the shear bond between concrete masonry units and mortar exhibits any rate dependency. An increase in shear bond strength was observed when loaded at a high strain rate. This data indicates that the CMU-mortar bond exhibits a rate dependent strength change and illustrates the need for further study of the CMU-mortar interface characteristics at high strain rates.

Concentration Effect of Silane Coupling Agents with Chloropropyl End Group on the Interfacial Characteristics of Glass/Nylon 6 Composites (유리섬유/나일론 6 복합재료의 계면특성에 미치는 Chloropropyl 말단기를 가진 실란결합체 농도의 영향)

  • Cho, Donghwan;Yun, Suk Hyang;Bang, Dae-Suk;Kim, Junkyung;Lim, Soonho;Park, Min
    • Journal of Adhesion and Interface
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2004
  • In this work, glass fiber/nylon 6 and woven glass fiber/nylon 6 composites have been fabricated using glass fiber reinforcements sized with 3-chloropropyltrimethoxysilane(CTMS) having a chloropropyl organo-functional group in the molecular chain end. The interfacial shear strength of glass fiber/nylon 6 composite was measured using a single fiber microbonding test and the interlaminar shear strength and the storage modulus of woven glass fabric/nylon 6 composites were measured using a short-warn shear test and a dynamic mechanical analysis, respectively, informing the effect of the concentration of CTMS on the properties. With increasing CTMS concentration, the interfacial properties of the composites were improved. The results on the interfacial shear strength, interlaminar shear strength, interlaminar failure pattern, and storage modulus with varying the CTMS concentration agree with each other.

  • PDF

Interfacial Reaction and Mechanical Property of BGA Solder Joints with LTCC Substrate (LTCC기판과 BGA 솔더접합부의 계면반응 및 기계적 특성)

  • Yoo, Choong-Sik;Ha, Sang-Su;Kim, Bae-Kyun;Jang, Jin-Kyu;Seo, Won-Chan;Jung, Seung-Boo
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.3
    • /
    • pp.202-208
    • /
    • 2009
  • The effects of aging time on the microstructure and shear strength of the Low Temperature Co-fired Ceramic (LTCC)/Ag pad/Electroless Nickel Immersion Gold (ENIG)/BGA solder joints were investigated through isothermal aging at $150^{\circ}C$ for 1000 h with conventional Sn-37Pb and Sn-3Ag-0.5Cu. $Ni_3Sn_4$ intermetallic compound (IMC) layers was formed at the interface between Sn-37Pb solder and LTCC substrate as-reflowed state, while $(Ni,Cu)_3Sn_4$ IMC layer was formed between Sn-3Ag-0.5Cu solder and LTCC substrate. Additional $(Cu,Ni)_6Sn_5$ layer was found at the interface between the $(Ni,Cu)_3Sn_4$ layer and Sn-3Ag-0.5Cu solder after aging at $150^{\circ}C$ for 500 h. Thickness of the IMC layers increased and coarsened with increasing aging time. Shear strength of both solder joints increased with increasing aging time. Failure mode of BGA solder joints with LTCC substrate after shear testing revealed that shear strength of the joints depended on the adhesion between Ag metallization and LTCC. Fracture mechanism of Sn-37Pb solder joint was a mixture of ductile and pad lift, while that of Sn-3Ag-0.5Cu solder joint was a mixture of ductile and brittle $(Ni,Cu)_3Sn_4$ IMC fracture morphology. Failure mechanisms of LTCC/Ag pad/ENIG/BGA solder joints were also interpreted by finite element analyses.

A study on the Measurement of Interface Friction between Soils and Fibers (흙과 섬유의 상호마찰 특성의 측정에 관한 연구)

  • 장병욱;서동욱;박영곤
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.467-472
    • /
    • 1998
  • The interface friction angle between soil and fibers is important to evaluate improvement of the shear strength on fiber mixed soils. Direct shear test and pullout tort conducted by an apparatus made specially for the purpose of this study, was analyzed to know how fiber and soils affect on interface friction angle. By the results, The value of interface friction angle of sandy soils is larger than that of clayey soils. As a diameter of fiber is large, the value of friction coefficient of sandy soil is increase and that of clayey soil is decrease. An interface friction angle of well graded soil is larger value than that of uniform graded soil

  • PDF