• Title/Summary/Keyword: Interconnected system

Search Result 602, Processing Time 0.033 seconds

Development of GIS Interconnected Corrosion Prediction System for Underground Metallic Structures (기존 GIS에 연계한 지하금속매설물의 부식예측시스템 개발)

  • Ha, Tae-Hyun;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.769-771
    • /
    • 1999
  • In general, the most of GIS is only deal with the material and geometric data which are position, radius, length etc except a corrosion data. In present, the owner of metallic structures having an interest in that my structures do corrode or not and how many life time is there? So, we need the development of GIS interconnected corrosion prediction system on the view point of the efficiency of operation and the protection for big accident. The results of development of its system are described in this paper. It can do life prediction and interference analysis and also newest corrosion data should be updated regularly.

  • PDF

Maximum Transfer Capability Calculating in Interconnected Power System using Monte-Carlo Sinulation (Monte-Carlo Simulation을 이용한 연계계통의 최대수송전력 산정)

  • Nam, Kwang-Woo;Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.360-362
    • /
    • 2000
  • This paper presents a probabilistic method for describing the transfer capability of one area in an interconnected power system. The approach is based on Monte Carlo simulation scheme. The result of this method is the probability distribution of transfer capability. The distribution yield a general framework for probabilistic analysis of STC. IEEE RTS-24 power system is utilized to evaluate the proposed method.

  • PDF

The effective recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources (다수의 분산형 전원이 연계된 배전계통에서 리크로저와 섹셔널라이저의 보호협조 방안)

  • Jung, Hyun-Jun;Choi, Joon-Ho;Nam, Hae-Kon;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.429-431
    • /
    • 2005
  • According to the second plan of the Korean Government about technology development, utilization and popularization of new renewable energy, the continuous growth of distributed resources are expected. Various studies about impact of distributed resource on distribution system have been already accomplished. Rut there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with fault position. The problems of these cases are investigated through simulation.

  • PDF

A Study on Algorithm for Calculating Power Transfer Capability in interconnected Power System using Interior Point Method (Interior Point Method를 이용한 연계계통에서의 수송능력산정 알고리즘개발에 관한 연구)

  • Jo, J.H.;Kim, Y.H.;Lee, Buhm;Choi, S.K.;Nam, K.W.;Moon, H.K.;Jung, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.210-213
    • /
    • 2001
  • This paper presents a efficient algorithm for calculating power transfer capability in interconnected large power system. The approach is based on interior point method. The efficiency of this method is favorable for large systems. IEEE RTS-96 power system is utilized to evaluate the proposed method.

  • PDF

A Study on the Customer Voltage Characteristic of Distribution System with Large Scale PV (대용량 태양광발전이 연계된 배전계통의 수용가 전압 특성해석에 관한 연구)

  • Kim, Byung-Ki;Ryu, Kyung-Sang;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • This paper deals with the analysis of the customer voltage characteristic in distribution system interconnected with large scale PV system. There would be many power quality issues which are caused by reverse power flow of PV system interconnected with distribution system. In order to analyze the effect of PV system on the customer voltage, detailed modeling method of distribution system and modified modelling method of PV system are proposed using PSCAD/EMTDC in this paper. So far, less than dozens KW of PV system can be simulated with the existing modelling method. Therefore, a new modeling method which can simulate the large scale PV system is proposed by considering the relationship equation on the phase and voltage in the current control algorithm. From the simulation result of proposed modelling method, it is confirmed that an optimal operation method in distribution system is suggested by analyzing the effect of PV system on customer voltage.

Network Operation Support System on Graph Database (그래프데이터베이스 기반 통신망 운영관리 방안)

  • Jung, Sung Jae;Choi, Mi Young;Lee, Hwasik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.22-24
    • /
    • 2022
  • Recently, Graph Database (GDB) is being used in wide range of industrial fields. GDB is a database system which adopts graph structure for storing the information. GDB handles the information in the form of a graph which consists of vertices and edges. In contrast to the relational database system which requires pre-defined table schema, GDB doesn't need a pre-defined structure for storing data, allowing a very flexible way of thinking about and using the data. With GDB, we can handle a large volume of heavily interconnected data. A network service provider provides its services based on the heavily interconnected communication network facilities. In many cases, their information is hosted in relational database, where it is not easy to process a query that requires recursive graph traversal operation. In this study, we suggest a way to store an example set of interconnected network facilities in GDB, then show how to graph-query them efficiently.

  • PDF

Supervisory Protection System of Microgird Interconnected to Low Voltage Grids (저압계통 연계형 마이크로그리드의 보호감시 시스템)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • This paper mainly proposes the protective coordination scheme of the microgrid system. The microgrid protection is identical to the conventional protection system separating the normal part and contingency part to reduce damage when the contingency occur at power cables, facilities. But they are different in the protection type. The conventional protection system only considers unidirectional current. However the microgrid protection should be considered not only unidirectional current but also backfeed current because various microsources and loads are installed in the microgrid system. In case the contingency occurs in microsource, when microgrid is interconnected to grid, the protection system should be configured to not separate microgrid from grid before the microsource is isolated to microgrid. And in case of fault occur in power system, the microsources should not isolated to microgrid before the static switch at PCC is tripped to separate from power system. Considering these characteristic of microgird, this paper proposes the protective coordination scheme of microgrid and implemented the on-line real time monitoring system. Especially in case the microgrid is connected to low voltage distribution system with 220/380V voltage level, the proposed protection method with power IT technology can solve the problems when the existing protective devices only applied to the microgrid system.

Implementation of the 50kW Utility Interconnected PV System Simulator and the Study of Financial Analysis (50kw급 PV시스템 시뮬레이터의 구현 및 경제성 분석에 관한 연구)

  • Lee, K.Y.;Kim, Y.G.;Shin, S.D.;Kim, H.G.;Chun, H.S.;Kim, B.C.;Min, W.K.;Kim, N.O.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11b
    • /
    • pp.157-159
    • /
    • 2008
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination, developed simulation results and financial analysis. The performance of photovoltaic system has been evaluated, analyzed with simulation and financial analysis results. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

  • PDF

Soft-switching Current Source inverter for Power System Interconnection (소프트 스위칭 전류원 인버터를 이용한 계통연계형 전력변환기)

  • 이준기
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.392-395
    • /
    • 2000
  • This paper proposes a soft-switching current -source inverter with a sitched-capacitor module The system operation was analyzed by a theoretical approach with equivalent circuits and verified by a computer simulation with ISPICE software. The proposed system could be effectively applied for the power converter of photovoltaic power generation interconnected with the power system.

  • PDF

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.