• 제목/요약/키워드: Intensity of Reflected Light

검색결과 81건 처리시간 0.026초

산란광속측정에 의한 연삭가공 표면 거칠기 측정방법 (A Method for Measurement of Roughness of Ground Surfaces by Using Fluxes of Scattered Lights)

  • 홍성욱;김현수
    • 한국정밀공학회지
    • /
    • 제12권4호
    • /
    • pp.46-54
    • /
    • 1995
  • This paper presents a simple method for measurenemt of roughness of ground surfaces. The present method utilizes fluxes of scattered lights condensed through lenses aligned along the specular direction. A theoretical analysis is preformed for the purpose of investigating the possibility of the method as well as determining the experimental condition. Experiments are also performed to show the effectiveness and robustness of the proposed method. The theoretical and experimental results show that the proposed method is simple enouth to implement and has a potential to identify a wide range of roughness of ground surfaces.

  • PDF

광 항적경로 모델을 이용한 피하조직에서의 광 특성에 관한 연구 (A Study on Optical Properties in Biological Tissue Using A Photon Path Diffusion Model)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권3호
    • /
    • pp.265-274
    • /
    • 1994
  • This paper proposes a method of noninvasive reflectance light to measure the blood fractional volume (Vb) and oxygen saturation ($SO_2$) of biological tissue. We chose the red light of 660nm and infrared light of 880nm. In Vivo reflectance data were obtained by the physiological changes front the surface of the skin over the calf in human subject. The reflected light intensity from different layers within a biological tissue was measured by specially designed reflectometer to apply photon path diffusion model. The collected data represent the changes of blood (ractional volume and oxygen saturation at each reflected light wavelengths. The data evaluation was assessed by examining the slopes of the plotted indices for the changes in oxygen saturation and blood (ractional volume. The results presented in this paper claim that light reflectance can separately discriminate the change of blood volume and that of oxygenation in muscle and also in skin.

  • PDF

Multistage Operation of Airlift Photobioreactor for Increased Production of Astaxanthin from Haematococcus pluvialis

  • Choi, Yoon-E;Yun, Yeoung-Sang;Park, Jong-Moon;Yang, Ji-Won
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권10호
    • /
    • pp.1081-1087
    • /
    • 2011
  • An internally radiating photobioreactor was applied for the production of astaxanthin using the unicellular green alga Haematococcus pluvialis. The cellular morphology of H. pluvialis was significantly affected by the intensity of irradiance of the photobioreactor. Small green cells were widespread under lower light intensity, whereas big reddish cells were predominant under high light intensity. For these reasons, growth reflected by cell number or dry weight varied markedly with light conditions. Even under internal illumination of the photobioreactor, light penetration was significantly decreased as algal cells grew. Therefore, we employed a multistage process by gradually increasing the internal illuminations for astaxanthin production. Our results revealed that a multistage process might be essential to the successful operation of a photobioreactor for astaxnthin production using H. pluvialis.

원형관로 영상을 이용한 관로주행 로봇의 자세 추정 (Robot Posture Estimation Using Circular Image of Inner-Pipe)

  • 윤지섭;강이석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권6호
    • /
    • pp.258-266
    • /
    • 2002
  • This paper proposes the methodology of the image processing algorithm that estimates the pose of the inner-pipe crawling robot. The inner-pipe crawling robot is usually equipped with a lighting device and a camera on its head for monitoring and inspection purpose of defects on the pipe wall and/or the maintenance operation. The proposed methodology is using these devices without introducing the extra sensors and is based on the fact that the position and the intensity of the reflected light from the inner wall of the pipe vary with the robot posture and the camera. The proposed algorithm is divided into two parts, estimating the translation and rotation angle of the camera, followed by the actual pose estimation of the robot . Based on the fact that the vanishing point of the reflected light moves into the opposite direction from the camera rotation, the camera rotation angle can be estimated. And, based on the fact that the most bright parts of the reflected light moves into the same direction with the camera translation, the camera position most bright parts of the reflected light moves into the same direction with the camera translation, the camera position can be obtained. To investigate the performance of the algorithm, the algorithm is applied to a sewage maintenance robot.

점접촉 탄성 유체 윤활에서의 띠 무의 강도에 의한 유막 두께 측정 (Measurement of Film Thickness by Fringe Intensity Analysis in Point Contact Elastohydrodynamic Lubrication)

  • 장시열;최언진
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제30회 추계학술대회
    • /
    • pp.103-113
    • /
    • 1999
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by the image processing method for the monochromatic incident light. Interference between the reflected lights both on Cr coating of glass disk and on super finished ball makes circular fringes, which are regarded as film thickness together with numbering of fringe order. In this study, we developed technology to measure the film thickness by analyzing dark and bright intensity waves which results from monochrome green light. Two typical fringe patterns only with intensity values 3re examined for the measurement of point contact EHL film thickness. We expect that this technology will give valuable clue to improve color image processing analysis for high resolution of EHL film thickness with white incident light.

  • PDF

Light Field 기술개발 동향 (Trends in the Technology Development of Light Field)

  • 전황수;한미경;장종현
    • 전자통신동향분석
    • /
    • 제33권2호
    • /
    • pp.56-63
    • /
    • 2018
  • A light field (LF) is a field for expressing the intensity and direction of light reflected from a subject in a 3D space. Dual LF cameras are equipped in smart phones in Korea, mainly those by Samsung and LG. Lytro, Apple, Nvidia, MIT Media Lab, Magic Lip, and NHK are also developing LF camera technologies. LF displays are being researched by ETRI, Samsung Electronics, KIST, KAIST, SNU, MIT Media Lab, USC, HP, Apple, Microsoft, SeeReal, Musion Eyeliner, Dimenco, and Holografika.

Monochromatic Image Analysis of Elastohydrodynamic Lubrication Film Thickness by Fringe Intensity Computation

  • Jang, Siyoul
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1704-1713
    • /
    • 2003
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by image processing method for the images from an optical interferometer with monochromatic incident light. Interference between the reflected lights both on half mirror Cr coating of glass disk and on super finished ball makes circular fringes depending on the contact conditions such as sliding velocity, applied load, viscosity-pressure characteristics and viscosity of lubricant under ambient pressure. In this situation the film thickness is regarded as the difference of optical paths between those reflected lights, which make dark and bright fringes with monochromatic incident light. The film thickness is computed by numbering the dark and bright fringe orders and the intensity (gray scale image) in each fringe regime is mapped to the corresponding film thickness. In this work, we developed a measuring technique for EHL film thickness by dividing the image patterns into two typical types under the condition of monochromatic incident light. During the image processing, the captured image is converted into digitally formatted data over the contact area without any loss of the image information of interferogram and it is also interpreted with consistency regardless of the observer's experimental experience. It is expected that the developed image processing method will provide a valuable basis to develop the image processing technique for color fringes, which is generally used for the measurement of relatively thin films in higher resolution.

자동차용 광원의 광도분포 측정장치(배광측정기)제작 (Construction of a Distribution Photometer System for Automobile Light Sources)

  • 김용완;김홍기;이인원;이완순;이상원
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권4호
    • /
    • pp.53-61
    • /
    • 1996
  • 광원에 대하여 서로 다른 여러 각도방향에서 광원을 바라볼 때 관측되는 광도 분포 및 재귀반사성능을 측정하기 위해 광도 분포 측정장치(배광측정기)를 제작하였다. 이 장치는 광원을 좌우로 360도, 상하로 $\pm$30도 회전 시킬수 있는 광원회전장치, 광검출기로 광전자증배관(PM Tube)을 쓰는 수광부 및 재귀반사성능 측정용 투광기와 제어 및 표시부로 구성되어 있다. 광도측정범위는 0.01~199900cd, 관측각범위는 0.2~1.5도 이고 광도의 측정오차는 $\pm$3%이다. 제작된 장치의 구조와 성능평가결과가 제기되었다.

  • PDF

혼탁매질에서 광분포에 관한 Monte Carlo 시뮬레이션 (Monte Carlo Simulation on Light Distribution in Turbid Material)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.11-20
    • /
    • 1998
  • The propagation of light radiation in a turbid medium is an important problem that confronts dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. Scattered light is measured as a function of the position(distance r, depth z) between the axis of the incident beam and the detection spot. Turbid sample yields a very forward-directed scattering pattern at short range of position from source to detector, whereas the thicker samples greatly attenuated the on-axis intensity at long range of position. The portions of scattered light reflected from or transmitted throughphantom depend upon internal reflectance and absorption properties of the phantom. Monte Carlo simulation method for modelling light transport in tissue is applied. It uses the photon is moved a distance where it may be scattered, absorbed, propagated, internally reflected, or transmitted out of tissue. The photon is repeatedly moved until it either escape from or is absorbed by the phantom. In order to obtain an optimum therapeutic ratio in phantom material, optimum control the light energy fluence rate is essential. This study is to discuss the physical mechanisms determining the actual light dose in phantom. Permitting a qualitative understanding of the measurements. It may also aid in designing the best model for laser medicine and application of medical engineering.