• 제목/요약/키워드: Intensity Factors

검색결과 1,963건 처리시간 0.027초

Evaluation of Stress Intensity Factors and T-Stress Using a Conservation Integral (보존적분을 이용한 응력강도계수와 T-응력의 계산)

  • 범현규;엄윤용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제18권1호
    • /
    • pp.121-126
    • /
    • 1994
  • A mutual integral, which has the conservation property, is applied to the problem of a crack in an isotropic elastic material. The stress intensity factors $K_{I}, K_{II}, K_{III}$ and T-stress for the problem in an infinite medium are easily obtained by using the mutual integral without solving the boundary value problem. The auxiliary solutions necessary in the proposed method are taken from the known asymptotic solutions. This method is amenable to numerical evaluation of the stress intensity factors and T-stress if the crack in a finite medium is considered.

Computation of mixed-mode stress intensity factors in functionally graded materials by natural element method

  • Cho, J.R.
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.43-51
    • /
    • 2019
  • This paper is concerned with the numerical calculation of mixed-mode stress intensity factors (SIFs) of 2-D isotropic functionally graded materials (FGMs) by the natural element method (more exactly, Petrov-Galerkin NEM). The spatial variation of elastic modulus in non-homogeneous FGMs is reflected into the modified interaction integral ${\tilde{M}}^{(1,2)}$. The local NEM grid near the crack tip is refined, and the directly approximated strain and stress fields by PG-NEM are enhanced and smoothened by the patch recovery technique. Two numerical examples with the exponentially varying elastic modulus are taken to illustrate the proposed method. The mixed-mode SIFs are parametrically computed with respect to the exponent index in the elastic modulus and external loading and the crack angle and compared with the other reported results. It has been justified from the numerical results that the present method successfully and accurately calculates the mixed-mode stress intensity factors of 2-D non-homogeneous functionally graded materials.

The Effects of Different Intensity of Aerobic Exercise for Four Weeks on Cardiovascular Risk Factors, Reactive Oxygen, and Antioxidant Enzymes in Old Mice (4주 유산소 운동의 운동강도가 노령 생쥐의 심혈관질환위험인자, 활성산소, 항산화효소에 미치는 효과)

  • Kim, Ji Hyun;Jeon, Songhee;Jeong, Ha Jin;Jeon, Mi Yang
    • Journal of Korean Biological Nursing Science
    • /
    • 제22권2호
    • /
    • pp.139-147
    • /
    • 2020
  • Purpose: The purpose of this study was to determine the effects of different intensity of aerobic exercise for four weeks on cardiovascular risk factors, reactive oxygen, and antioxidant enzymes in old mice. Methods: Eighteen male C57BL/6 mice age 18 months were randomly classified into the control group (n= 6), the moderate intensity exercise group (n= 6), and the low intensity exercise group (n= 6). The training groups performed the aerobic exercise twice daily for 20 minutes, five days weekly for four weeks. Data were analyzed using descriptive statistics, analysis of variance (ANOVA), the Chi-square test, and the Tukey's test with the SPSSWIN 21.0 program. Results: In this study, among the risk factors of cardiovascular disease, blood sugar (BS) (p= .023) and total cholesterol (TC) (p= .001) were significantly different between the moderate intensity exercise group and the control group. Additionally, there were significant differences in the reactive oxygen malondialdehyde (MDA) (p= .001), the antioxidant enzymes superoxide dismutase (SOD) (p< .001) and glutathione reductase (GR) (p= .015) between the moderate intensity exercise group and the control group. Conclusion: This finding suggests that moderate intensity aerobic exercise promotes the activity of antioxidant enzymes and lowers cardiovascular risk factors in older mice.

Analysis of Crack Growth in the Stiffened Panels by using Finite Element Method (유한요소법을 이용한 보강판의 균열거동해석)

  • 이환우;전원석
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제17권4호
    • /
    • pp.197-202
    • /
    • 2000
  • A simple numerical procedure is presented to determine the stress intensity factors for crack in a stiffened panel subjected to a uniaxial uniform stress normal to the crack. Two types of stiffened panels are analyzed by the finite element method for various values of crack lengths, stiffness ratios, and stiffener spacings. From the finite element solution, the stress intensity factors were determined by using hybrid extrapolation method. Results are presented in graphical forms for upper mentioned parameters.

  • PDF

Anaysis of the Interfacial Stress Intensity Factors and Fatigue Crack Growth Behaviour for the Edge Interface Crack in the Dissimilar Materials (이종재료 접합재의 편측접합계면균열의 응력확대계수 해석 및 피로균열성장 해석)

  • 이갑래;최용식
    • Journal of the Korean Society of Safety
    • /
    • 제6권2호
    • /
    • pp.5-13
    • /
    • 1991
  • In this paper, the interfacial stress intensity factors( $K_{i}$$K_1$+i $K_2$) for the edge interface crack in the dissimilar materials(isotropic-isotropic materials, isotropic-composite materials) were analysed by BEM(Boundary Element Method). The fatigue crack growth behaviour was investigated by load constant fatigue test. From the experimental results, the relationship between da/dN and interfacial stress intensity facto, ( $K_{i}$ or $K_1$) can be expressed by Paris'law for homogeneous materials.s.s.

  • PDF

Evaluation of Stress Intensity Factors for an Electrostrictive Crack with an Electric Yielding Zone (전기적 항복영역을 갖는 전왜균열에 대한 응력강도계수 계산)

  • 범현규;정은도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.469-472
    • /
    • 2000
  • a crack with electrically impermeable surfaces in an electrostrictive material subjected to uniform electric loading is analysed. A strip yield zone model is employed to investigate the effect of electric yielding on stress intensity factor. complete forms of electric fields and elastic fields for the crack are derived by using complex function theory. /the stress intensity factors are obtained based on the strip yield zone model.

  • PDF

Determination of Thermal Shock Stress Intensity Factor for Elliptical Crack by Modified Vainshtok Weight Function Method (수정 Vainshtok 가중함수법에 의한 타원균열의 열충격 응력세기계수의 결정)

  • 이강용;김종성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권2호
    • /
    • pp.463-474
    • /
    • 1995
  • Modified Vainshtok weight function method is developed. The thermal shock stress intensity factors for elliptical surface cracks existed in the thin and thick walled cylinders are determined. The present results are compared with previous solutions and shown to be good agreement with them.

비틀림하의 복합원통에 있는 원주 표면균열에 대한 응력 확대 계수

  • Kim, Yeong-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제17권9호
    • /
    • pp.151-157
    • /
    • 2000
  • Stress intensity factors for the circumferential surface crack of a long composite cylinder under torsion is investigated. The problem is formulated as a singular integral equation of the first kind with a Cauchy type kernel using the integral transform technique. The mode III stress intensity factors at the crack tips are presented when (a) the inner crack tip is away from the interface and (b) the inner crack tip is at the interface.

  • PDF

The Effects of Resting Physical Factors on Distance and Intensity of Six-Minute Walk Test in Healthy Female Subjects

  • Kang, Dong-Yeon;Lee, Hye Young
    • The Journal of Korean Physical Therapy
    • /
    • 제29권5호
    • /
    • pp.281-286
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the correlations among the resting physical factors related to a six-minute walk test (6MWT) and to determine the effects of the resting physical factors on the distance and intensity related to the 6MWT in healthy female subjects. Methods: A total of 43 healthy female subjects ($22.84{\pm}3.90yrs$) participated in this study. They performed the 6MWT, and the physical factors related to the 6MWT were assessed. SPSS 20.0 was used to analyze the data, and the mean and standard deviation were calculated, and the collected data were analyzed by the Pearson's correlation coefficient (among physical factors related to 6MWT) and independent t-test (between six-minute walk distance [6MWD] groups and six-minute walk intensity [6MWI] groups). Results: The 6MWD had a significant negative correlation with the resting HR (beat/min) in healthy female subjects (r=-0.49, p<0.05). The 6MWI had a significant negative correlation with the resting systolic blood pressure (SBP) (r=-0.45, p<0.01). A comparison of the 6MWD revealed the long distance group (LDG, 700-799 m) to be significantly higher than the middle distance group (MDG, 600-699 m) in the 6MWI (%), %predicted distance (%), predicted VO2max (mL/kg/min), resting HR (beat/min), and resting SBP (mmHg)(p<0.05). In the comparison of 6MWI, the moderate intensity group (MIG, 64-75%HRmax) was significantly lower than the low intensity group (LIG, 50-63%HRmax) in the resting SBP (mmHg) (p<0.05). Conclusion: These results suggest that the resting physical factors are related to the 6MWD and 6MWI of the 6MWT in healthy females. In particular, SBP is associated with not only the 6MWD but also the 6MWI in 6MWT.

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.