• Title/Summary/Keyword: Integrated test

Search Result 2,110, Processing Time 0.028 seconds

Experimental approach to evaluate software reliability in hardware-software integrated environment

  • Seo, Jeongil;Kang, Hyun Gook;Lee, Eun-Chan;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1462-1470
    • /
    • 2020
  • Reliability in safety-critical systems and equipment is of vital importance, so the probabilistic safety assessment (PSA) has been widely used for many years in the nuclear industry to address reliability in a quantitative manner. As many nuclear power plants (NPPs) become digitalized, evaluating the reliability of safety-critical software has become an emerging issue. Due to a lack of available methods, in many conventional PSA models only hardware reliability is addressed with the assumption that software reliability is perfect or very high compared to hardware reliability. This study focused on developing a new method of safety-critical software reliability quantification, derived from hardware-software integrated environment testing. Since the complexity of hardware and software interaction makes the possible number of test cases for exhaustive testing well beyond a practically achievable range, an importance-oriented testing method that assures the most efficient test coverage was developed. Application to the test of an actual NPP reactor protection system demonstrated the applicability of the developed method and provided insight into complex software-based system reliability.

Strain and deformation angle for a steel pipe elbow using image measurement system under in-plane cyclic loading

  • Kim, Sung-Wan;Choi, Hyoung-Suk;Jeon, Bub-Gyu;Hahm, Dae-Gi;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.190-202
    • /
    • 2018
  • Maintaining the integrity of the major equipment in nuclear power plants is critical to the safety of the structures. In particular, the soundness of the piping is a critical matter that is directly linked to the safety of nuclear power plants. Currently, the limit state of the piping design standard is plastic collapse, and the actual pipe failure is leakage due to a penetration crack. Actual pipe failure, however, cannot be applied to the analysis of seismic fragility because it is difficult to quantify. This paper proposes methods of measuring the failure strain and deformation angle, which are necessary for evaluating the quantitative failure criteria of the steel pipe elbow using an image measurement system. Furthermore, the failure strain and deformation angle, which cannot be measured using the conventional sensors, were efficiently measured using the proposed methods.

Empirical Evidence on the Integration of Major Fishery Product Import Markets in South Korea: Focus on Frozen Pollock, Frozen Long Arm Octopus, and Frozen Hairtail (국내 주요 수산물 수입시장의 통합정도 : 냉동명태, 냉동낙지, 냉동갈치 시장을 중심으로)

  • Lim, Eun-Son;Kim, Ki-Soo
    • The Journal of Fisheries Business Administration
    • /
    • v.46 no.3
    • /
    • pp.31-49
    • /
    • 2015
  • This study examines whether or not the South Korean major fishery product import markets; Frozen Pollock, Frozen Long Arm Octopus, and Frozen Hairtail are integrated. We are utilizing the Multivariate and Bivariate Johansen Co-integration test to see if the law of one price(LOP) holds in each market or not. The empirical results show that even though import prices from different countries affect each other in each South Korean major fishery product import market, there is no evidence of LOP in any fishery product import market, which means that none of the markets are integrated. Based on these results, we could expect that the three major fishery product import markets show monopolistic competition among import countries. we would also see whether or not any country plays the role of a price leader in any of the markets. Based on weak exogeneity test results, we might expect that the United States and Malaysia are price leaders in the South Korean Frozen Pollock Import Market and Frozen Long Arm Octopus Import Market, respectively; however, we need to study more on this in the future.

Analysis of Air Current Characteristics for Installing Wind Turbines Between Buildings (건물 사이에 풍력발전기를 설치하기 위한 기류특성분석)

  • Park, Min-Woo;You, Jang-Youl;Sohn, Young-Moo;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.117-125
    • /
    • 2018
  • Recently, various building integrated wind power (BIWP) approaches have been used to produce energy by installing wind power generators in high-rise buildings constructed in urban areas. BIWP has advantages in that it does not require support to position the turbine up to the installation height, and the energy produced by the wind turbine can be applied directly to the building. The accurate evaluation of wind speed is important in urban wind power generation. In this study, a wind tunnel test and computational fluid dynamics (CFD) analysis were conducted to evaluate the wind speed for installing wind turbines between buildings. The analysis results showed that the longer the length of the buildings, which had the same height, the larger the wind speed between the two buildings. Furthermore, the narrower the building's width, the higher the wind velocity; these outcomes are due to the increase in the Venturi effect. In addition, the correlation coefficient between the results of the wind tunnel test and the CFD analysis was higher than 0.8, which is a very high value.

Seismic performance of hybrid isolation plate-shell integrated concrete LSS

  • Lei Qi;Xuansheng Cheng;Shanglong Zhang;Yuyue Bu;Bingbing Luo
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.57-67
    • /
    • 2024
  • To assess the seismic performance of Plate-Shell Integrated Concrete Liquid-Storage Structure (PSICLSS), a scaled test model was constructed. This model incorporated a hybrid isolation system, which combined shape memory alloy (SMA), lead-cored rubber isolation bearing (LRB) and sliding isolation bearing (SB). By conducting shaking table test, the dynamic responses of both non-isolated and hybrid-isolated PSICLSS were analyzed. The results show that the hybrid isolation system can effectively reduce the acceleration and displacement responses of the structure. However, it also results in an increase in local hydrodynamic pressure and liquid sloshing height. Under extreme earthquake action, the displacement of isolation layer is small. When vertical ground motion is taken into account, the shock absorption rate of horizontal acceleration decreases. The peak hydrodynamic pressure increases significantly, and the peak hydrodynamic pressure position also changes. The maximum displacement of isolation layer increases, the residual displacement decreases.

Effects of integrated obesity management program on obese elementary school children (초등학교 비만아동을 위한 통합비만관리프로그램의 효과)

  • Cho, In-Sook;Ryu, Hyun-Sook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1378-1389
    • /
    • 2020
  • The purpose of this study was to develop a integrated obesity management program and measure the effects of the program on obesity, life style, dietary self-efficacy and exercise self-efficacy among obese elementary school children. The integrated obesity management program was provided for the experimental group of 4~6th grade elementary school students for 8 weeks. The program included obesity related health educations based on behavior modification and self-efficacy once a week, exercise classes three times a week. Method: There were 30 children with obesity in the experimental and 28 in the control groups. The collected data were analyzed by the 𝑥2-test, independent t-test and repeated measure ANOVA. Results: After 8weeks of participation in the program, the experimental group showed significantly lower body mass index (p<.01), percent body fat(p<.05) and obesity index(p<.01), significantly higher life style (p<.05)), dietary self-efficacy(p<.001), exercise self-efficacy(p<.05) than those in the control group. Conclusion: This study provides evidence that integrated obesity management program is effective nursing intervention for managing child obesity.

A Study on Processor Monitoring for Integration Test of Flight Control Computer equipped with A Modern Processor (최신 프로세서 탑재 비행제어 컴퓨터의 통합시험을 위한 프로세서 모니터링 연구)

  • Lee, Cheol;Kim, Jae-Cheol;Cho, In-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.10
    • /
    • pp.1081-1087
    • /
    • 2008
  • This paper describes limitations and solutions of the existing processor-monitoring concept for a military supersonics aircraft Flight Control Computer (FLCC) equipped with modern architecture processor to perform the system integration test. Safecritical FLCC integration test, which requires automatic test for thousands of test cases and real-time input/output test condition generation, depends on the processor-monitoring device called Processor Interface (PI). The PI, which relies upon on the FLCC processor's external address and data-bus data, has some limitations due to multi-fetching capability of the modern sophisticated military processors, like C6000's VLIW (Very-Long Instruction Word) architecture and PowerPC's Superscalar architecture. Several techniques for limitations were developed and proper monitoring approach was presented for modem processor-adopted FLCC system integration test.

ETRI Protocol Test Architecture and Its Application to CCS Network Service Part Protocols (ETRI 프로토콜 검증구조와 CCS망 서비스부 프로토콜에의 응용)

  • Gang, Yeong-Man;Cheon, Dae-Nyeong;Cha, Yeong-Hwan;Baek, Yeong-Sik;Choe, Yang-Hui
    • ETRI Journal
    • /
    • v.10 no.2
    • /
    • pp.3-12
    • /
    • 1988
  • Several ISDN (Integrated Services Digital Network) protocols have implemented at ETRI (Electronics and Telecommunications Research Institute) in an experimental network so that functional characteristics of the protocols under test could be certified against their protocol specifications with the help of the ETRI protocol test facilities. This paper describes ETRI protocol test architecture and its application to testing the NSP (Network Service Part) protocols : MTP (Message Transfer Part) level 3 and SCCP (Signalling Connection Control Part) of the CCITT CCS (Common Channel Signalling ) system No. 7 The test architecture presented here allows tests for two different protocol classes : peer-to-peer and multipeer protocolos. Some extensions are made to the conventional test architectures, namely the test coordination, test result transfer and network state observation method.

  • PDF

COMS DATS Implementation and Test (통신해양기상위성 데이터 송수신 서브시스템의 구축 및 시험)

  • Park, Durk-Jong;Kim, Su-Jin;Ahn, Sang-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.459-470
    • /
    • 2008
  • DATS which is one of three subsystems of IDACS is responsible to receive Sensor Data, LRIT and HRIT in L-Band and transmit LRIT and HRIT in S-Band from/to COMS satellite. This paper shows detailed test procedures used to verify the performance and functionality of DATS after its implementation was completely finished. As a part of efforts to verify key DATS performance, G/T and EIRP were measured by using solar flux density as radio source. Regarding the verification of DATS functionality, RF loop-back test was conducted to validate if there is no BER degradation excepting MODEM/BB implementation loss occurred in the integrated DATS. Integrated with 13m antenna, DATS successfully restored image from received MTSAT-1R broadcasting data, LRIT and HRIT, of which frequencies are all L-Band. S-Band transmission was also verified through test antenna placed away from 13m antenna by measuring real LRIT and HRIT spectrum in S-Band. From those test results, DATS is determined to be fully ready to communicate with COMS in L-Band and S-Band.

Development of System Integration Laboratory for the Verification of UAV Avionics System Requirements (무인기 항공전자시스템 요구도 검증을 위한 통합시험환경 개발)

  • Jo, Young-Wo;Kim, Bong-Gyu;Park, Jae-Sung;Lee, Jae-Uk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.5
    • /
    • pp.446-453
    • /
    • 2012
  • As part of the integration phases in developing a UAV, a System Integration Laboratory (SIL) has been developed to provide integrated test capability for the verification of avionics system requirements. The SIL has realized primary functions that are common in manned aircraft SIL's, and specialized laying stress on test data visualization and test automation under the closed-loop structure of the ground control simulation, aircraft simulation and flight simulation components. Those design results have led to easy and sure verification of lots of complex requirements of the UAV avionics system. The functions and performances of the SIL have been proved in four gradational test steps and checked to operate successfully in aircraft System Integration Test Environment for the integration of UAV ground station and aircraft.