• Title/Summary/Keyword: Integrated load analysis

Search Result 251, Processing Time 0.023 seconds

A Hybrid Correction Technique of Missing Load Data Based on Time Series Analysis

  • Lee, Chan-Joo;Park, Jong-Bae;Lee, Jae-Yong;Shin, Joong-Rin;Lee, Chang-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.254-261
    • /
    • 2004
  • Traditionally, electrical power systems had formed the vertically integrated industry structures based on the economics of scale. However, power systems have been recently reformed to increase their energy efficiency. According to these trends, the Korean power industry underwent partial reorganization and competition in the generation market was initiated in 2001. In competitive electric markets, accurate load data is one of the most important issues to maintaining flexibility in the electric markets as well as reliability in the power systems. In practice, the measuring load data can be uncertain because of mechanical trouble, communication jamming, and other issues. To obtain reliable load data, an efficient evaluation technique to adjust the missing load data is required. This paper analyzes the load pattern of historical real data and then the tuned ARIMA (Autoregressive Integrated Moving Average), PCHIP (Piecewise Cubic Interpolation) and Branch & Bound method are applied to seek the missing parameters. The proposed method is tested under a variety of conditions and also tested against historical measured data from the Korea Energy Management Corporation (KEMCO).

A Correction Technique of Missing Load Data Based on ARIMA Model (ARIMA 모형에 기초한 수요실적자료 보정기법 개발)

  • 박종배;이찬주;이재용;신중린;이창호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.405-413
    • /
    • 2004
  • Traditionally, electrical power systems had the vertically-integrated industry structures based on the economics of scale. However power systems have been recently reformed to increase the energy efficiency of the power system. According to these trends, Korean power industry has been partially restructured, and the competitive generation market was opened in 2001. In competitive electric markets, correct demand data are one of the most important issue to maintain the flexible electric markets as well as the reliable power systems. However, the measuring load data can have the uncertainty because of mechanical trouble, communication jamming, and other things. To obtain the reliable load data, an efficient evaluation technique to adust the missing load data is needed. This paper analyzes the load pattern of historical real data and then the turned ARIMA (Autoregressive Integrated Moving Average) model, PCHIP(Piecewise Cubic Interporation) and Branch & Bound method are applied to seek the missing parameters. The proposed method is tested under a variety of conditions and tested with historical measured data from the Korea Energy Management Corporation (KEMCO).

Blast Analysis of Concrete Structure using Arbitrary Lagrangian-Eulerian Technique (Arbitrary Lagrangian-Eulerian기법을 적용한 콘크리트 구조물의 폭발해석)

  • Yi, Na-Hyun;Kim, Sung-Bae;Nam, Jin-Won;Lee, Sung-Tae;Kim, Jang-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.269-272
    • /
    • 2008
  • Blast load, an impulsive load with extremely short time duration with very high pressure, is effected by ground and air condition, weight of charge, shape and location of structure. In this study, a blast dynamic analysis for the air-structural integrated model considering dynamic properties of materials and simulation of complex blast wave propagation by Arbitrary Lagrangian- Eulerian technique is suggested to perform an accurate blast analysis of concrete structures. For the verification of the proposed blast analysis method, which is the air-structure integrated model using ALE technique, the comparison of analysis and experimental results is performed. The verification confirms that the simulation of realistic behavior of RC wall structures is possible using ALE method. Also, the example cases which have been analyzed using this method show that the estimation to the structural failure criterion for blast load failure can be represented by energy absorbtion procedure.

  • PDF

Application of a Multidisciplinary Design Optimization Algorithm to Design of a Belt Integrated Seat Considering Crashworthiness (충돌을 고려한 안전띠 일체형 의자의 다분야 통합최적설계)

  • Shin Moon-Kyun;Kang Byung-Soo;Park Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.395-402
    • /
    • 2005
  • Recently Multidisciplinary Design Optimization Based on Independent Subspaces (MDOIS), an MDO (multidisciplinary design optimization) algorithm, has been proposed. In this research, an MDO problem is defined for design of a belt integrated seat considering crashworthiness, and MDOIS is applied to solve the problem. The crash model consists of an airbag, a belt integrated seat (BIS), an energy absorbing steering system, and a safety belt. It is found that the current design problem has two disciplines - structural nonlin- ear analysis and occupant analysis. The interdisciplinary relationship between the disciplines is identified and is addressed in the system analysis step in MDOIS. Interdisciplinary variables are belt load and stiffness of the seat, which are determined in system analysis step. The belt load is passed to the structural analysis subspace and stiffness of the seat back frame to the occupant analysis subspace. Determined design vari- ables in each subspace are passed to the system analysis step. In this way, the design process iterates until the convergence criterion is satisfied. As a result of the design, the weight of the BIS and Head Injury Crite- rion (HIC) of an occupant are reduced with specified constraints satisfied at the same time. Since the system analysis cannot be formulated in an explicit form in the current example, an optimization problem is formu - lated to solve the system analysis. The results from MDOIS are discussed.

Analysis of Door Height Difference and Door Flatness Difference of Built-in Side-by-Side Refrigerator Using Cabinet-Door Integrated Model (캐비닛-도어 통합모델을 이용한 빌트인 양문형 냉장고의 도어 상하단차와 앞뒤단차 해석)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.76-83
    • /
    • 2018
  • A cabinet-door integrated finite element model was constructed for a built-in side-by-side refrigerator with an ice dispenser, and its deformation was analyzed using the ANSYS finite element software. As loads, the food load needed to fill in the cabinet and doors and the thermal load occurring during normal operation conditions were taken into consideration. The door height difference (DHD) and door flatness difference (DFD) between the two doors of the freezing and refrigerating compartments were derived. The DHD and DFD under the assembled condition without applied loads satisfied the acceptance criteria specified by the refrigerator manufacturer. It appeared that the food load increases the DFD slightly. The thermal load tends to increase the differences because of the thermal deformation, especially the DFD, of the cabinet and doors.

Analysis and Design of a Separate Sampling Adaptive PID Algorithm for Digital DC-DC Converters

  • Chang, Changyuan;Zhao, Xin;Xu, Chunxue;Li, Yuanye;Wu, Cheng'en
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2212-2220
    • /
    • 2016
  • Based on the conventional PID algorithm and the adaptive PID (AD-PID) algorithm, a separate sampling adaptive PID (SSA-PID) algorithm is proposed to improve the transient response of digitally controlled DC-DC converters. The SSA-PID algorithm, which can be divided into an oversampled adaptive P (AD-P) control and an adaptive ID (AD-ID) control, adopts a higher sampling frequency for AD-P control and a conventional sampling frequency for AD-ID control. In addition, it can also adaptively adjust the PID parameters (i.e. $K_p$, $K_i$ and $K_d$) based on the system state. Simulation results show that the proposed algorithm has better line transient and load transient responses than the conventional PID and AD-PID algorithms. Compared with the conventional PID and AD-PID algorithms, the experimental results based on a FPGA indicate that the recovery time of the SSA-PID algorithm is reduced by 80% and 67% separately, and that overshoot is decreased by 33% and 12% for a 700mA load step. Moreover, the SSA-PID algorithm can achieve zero overshoot during startup.

Development of a Web-based Integrated System for Flow of Agricultural Products (Web 기반의 농산물 유통분석 통합 시스템 개발)

  • Suh, Kyo;Lee, Jeong-Jae;Kim, Tae-Gon
    • Journal of Korean Society of Rural Planning
    • /
    • v.11 no.2 s.27
    • /
    • pp.1-8
    • /
    • 2005
  • This study is to develop a web-based integrated system for flow of agricultural products based on recent researches with engineering approach. The system stands on the basis of web for accessibility and usability. Three parts of the system consist of analysis of regional shipping characteristics using tank model, estimation of pallet load efficiency with Monte Carlo Simulation, a long term prediction of market price with reliability analysis. Besides a decision support module for selecting optimal shipping market is added through synthesizing techniques and spatial analysis using GIS and applied to Chinese cabbage of Pyeongchang in 2004.

A Study on a Methodology of Determining an Appropriate Load Power Factor Effectively by the Use of Reactive Power Sensitivity and Load Duration Curve (무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구)

  • Lee, Byung Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1782-1790
    • /
    • 2012
  • In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.

Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System (전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구)

  • Choi, Gyeong-Seok;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

Conceptual Design and Wind Load Analysis of Tall Building

  • Lee, S.L.;Swaddiwudhipong, S.
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • The paper describes the conceptual design, structural modelling and wind load analysis of tall buildings. The lateral stiffness of the building can be obtained economically through the interaction of core walls with peripheral frame tube and/or bundle of frame tubes and integrated design of the basement. The main structural components should be properly distributed such that the building will deflect mainly in the direction of the applied force without inducing significant response in other directions and twist. The cost effectiveness can be further enhanced through close consultation between architects and engineers at an early stage of conceptual design. Simplified structural modelling of the building and its response in three principal directions due to wind load are included. Effects of the two main structural components on the performances of a 70-story reinforced concrete building in terms of peak drift and maximum acceleration under wind load are discussed.

  • PDF