• 제목/요약/키워드: Integrated Type Case

검색결과 206건 처리시간 0.024초

건물 적용 유형별 BIPVT 집열기 열적 실험성능 비교 (The Thermal Performance Comparison of BIPVT Collector Applied on Roofs and Facades)

  • 강준구;김진희;김준태
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 추계학술대회
    • /
    • pp.269-272
    • /
    • 2009
  • The temperature of PV modules that integrated into building facades or roof increases that could reduce the electrical efficiency of the PV system. In order to incresae PV system's efficiency it is very important to remove the heat from the PV modules. For this purpose, hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The solar collector utilizing this thermal effect is called photovoltaic-thermal(PVT) solar collector. This paper compares the experimental performance of building-integrated PVT collectors that applied on building roof and facade. There are two different case: a roof-integrated PVT type and a facade-integrated PVT type. The experimental results show that the collected thermal energy of the roof-integrated type was 24% higher, compared to that of the facade-integrated.

  • PDF

토션 바 스프링을 적용한 일체형 도어체커 개폐력 해석 (Door Effort Analysis for Door Checker of Integrated Type with Torsion Bar Spring)

  • 윤상민;강성종
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.86-91
    • /
    • 2012
  • Door effort was calculated for a new door checker with torsion bar spring and integrated checker case by FE analysis. A hybrid checker arm which has peaks and valleys only on the upper surface was adopted to reduce noise in operation and make operation with more distinctive steps. The checker arm was modeled using shell elements to estimate both the longitudinal and the lateral resistance force by checker arm. By combining the checker arm resistance force obtained from analysis and the door self-closing force by the theoretical calculation, door effort was predicted to show the good correlation with test results. In addition the unrolling effect of roller model was investigated and a new roller type for more smooth rolling was studied.

철도 사고 및 장애의 인적오류 유형 분석 (An Analysis of Human Error Mode and Type in the Railway Accidents and Incidents)

  • 고종현;정원대;김재환
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.66-71
    • /
    • 2007
  • Human error is one of the major contributors to the railway accidents or incidents. In order to develop an effective countermeasure to remove or reduce human errors, a systematic analysis should be preferentially performed to identify their causes, characteristics, and types of human error induced in accidents or incidents. This paper introduces a case study for human error analysis of the railway accidents and incidents. For the case study, more than 1,000 domestic railway accidents or incidents that happened during the year of 2004 have been investigated and a detailed error analysis was performed on the selected 90 cases, which were obviously caused by human error. This paper presents a classification structure for human error analysis, and summarizes the analysis results such as causes of the events, error modes and types, related worker, and task type.

한반도 겨울철 강수 유형에 따른 전지구 수치모델(GRIMs) 예측성능 검증 (Evaluation of Predictability of Global/Regional Integrated Model System (GRIMs) for the Winter Precipitation Systems over Korea)

  • 연상훈;서명석;이주원;이은희
    • 대기
    • /
    • 제32권4호
    • /
    • pp.353-365
    • /
    • 2022
  • This paper evaluates precipitation forecast skill of Global/Regional Integrated Model system (GRIMs) over South Korea in a boreal winter from December 2013 to February 2014. Three types of precipitation are classified based on development mechanism: 1) convection type (C type), 2) low pressure type (L type), and 3) orographic type (O type), in which their frequencies are 44.4%, 25.0%, and 30.6%, respectively. It appears that the model significantly overestimates precipitation occurrence (0.1 mm d-1) for all types of winter precipitation. Objective measured skill scores of GRIMs are comparably high for L type and O type. Except for precipitation occurrence, the model shows high predictability for L type precipitation with the most unbiased prediction. It is noted that Equitable Threat Score (ETS) is inappropriate for measuring rare events due to its high dependency on the sample size, as in the case of Critical Success Index as well. The Symmetric Extreme Dependency Score (SEDS) demonstrates less sensitivity on the number of samples. Thus, SEDS is used for the evaluation of prediction skill to supplement the limit of ETS. The evaluation via SEDS shows that the prediction skill score for L type is the highest in the range of 5.0, 10.0 mm d-1 and the score for O type is the highest in the range of 1.0, 20.0 mm d-1. C type has the lowest scores in overall range. The difference in precipitation forecast skill by precipitation type can be explained by the spatial distribution and intensity of precipitation in each representative case.

Cold facade형 BIPV시스템의 발전성능 분석 (Analysis of Performance of Building Integrated PV System of Cold Facade type)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF

업무생산성 향상을 위한 종합정보업무환경 구축에 관한 연구 (A Study on the Development of Integrated Information Work Environment for Improving Work Productivity)

  • 성태경;조창현
    • Asia pacific journal of information systems
    • /
    • 제9권3호
    • /
    • pp.127-142
    • /
    • 1999
  • There have been strong arguments that the best organizational type for the information society is a network organization which is intelligent and learning-oriented as well as has problem solving capacities rather than a traditional passive organization which strictly follows standard operating procedures. In this perspective, integrated information work environment emerges as attractive work environment for the 21st century. Integrated information work environment is defined as an integrated electronic environment that is available to and readily accessible be each employee and is structured to provide immediate, individualized on-line access to the full range of information, software, guidance, advice and assistance, data, images, tools, and assessment and monitoring systems to permit job performance with minimal support and intervention by others. Case study was performed to measure the productivity improvement by implementing integrated information work environment in life insurance company. The results show that there is a number of indications of strong work productivity improvements.

  • PDF

복공판과 주형을 일체화한 가설교량에 대한 합성효과 검토 사례연구 (A Case study on Effect of Compositeness for Temporary Bridge Integrated Lining Board and Girder)

  • 윤우현;정지승;이종순;윤용석;양성돈
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.34-41
    • /
    • 2012
  • In this study, it has been proposed the new type of temporary bridge which is structural performance maximization to integrated cover plate and girder as well as roll of lining board. Of all temporary bridge integrated cover plate and main girder in the form of a new type of structure is advantageous for the judge, but to the field of transport difficulties and challenges due to high altitude operations to take advantage of this challenge and deliver a structured, easy transport, and the synthesis of lining board possible was proposed. Lining board proposed in this study through experimental synthesis and analysis of the factors that influence the effectiveness of the construction and economic development in the construction method was superior, compared to the conventional lining board.

Multi-criteria Vertical Handoff Decision Algorithm Using Hierarchy Modeling and Additive Weighting in an Integrated WLAN/WiMAX/UMTS Environment- A Case Study

  • Bhosale, Sahana;Daruwala, Rohin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권1호
    • /
    • pp.35-57
    • /
    • 2014
  • Multi-criteria decision making (MCDM) algorithms play an important role in ensuring quality of service in an integrated HetNets (Heterogeneous Networks). The primary objective of this paper is to develop a multi-criteria vertical handoff decision algorithm (VHDA) for best access network selection in an integrated Wireless Local Area Network (WLAN)/Universal Mobile Telecommunications System (UMTS)/Worldwide Interoperability for Microwave Access (WiMAX) system. The proposed design consists of two parts, the first part is the evaluation of an Analytic Hierarchy Process (AHP) to decide the relative weights of handoff decision criteria and the second part computes the final score of the weights to rank network alternatives using Simple Additive Weighting (SAW). SAW ranks the network alternatives in a faster and simpler manner than AHP. The AHP-SAW mathematical model has been designed, evaluated and simulated for streaming video type of traffic. For other traffic type, such as conversational, background and interactive, only simulation results have been discussed and presented in brief. Simulation results reveal that the hierarchical modelling and computing provides optimum solution for access network selection in an integrated environment as obtained results prove to be an acceptable solution to what could be expected in real life scenarios.

STEP을 이용한 해양건축물의 통합구조설계 기법 (Integrated Structural Design of Oceanic Buildings using STEP)

  • 송화철
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.77-86
    • /
    • 2000
  • The planning process of complex projects in oceanic architectural engineering is characterized by the cooperation of many involved specialists and by a high degree of information exchange. In order to improve the quality of the structural design of oceanic buildings, information of different involved partners in the planning process has to be integrated. This paper aims to introduce a concept of the integrated structural design for the floating-type oceanic building using STEP(Standard for the Exchange of Product Model Data). STEP(ISO 10303) is an international standard for the computer-interpretable representation and exchange of product data and it provides a consistent data exchange format and application interfaces between different application systems. In this paper, the structural design process and information of oceanic buildings is analyzed and product models are preposed fir the exchange of the structural design information between superstructure and floating structure. The entities for calculating wind loads, metacenter and restoring forces are represented by Express. As a case study a floating hotel is applicated to describe the STEP physical file.

  • PDF

지붕재 일체형 태양전지 모듈의 개발에 따른 내구성 평가 (조립식 건축시스템을 중심으로) (A Study on the Development of Roof Integrated PV Module (Focused on the Prefab Building System))

  • 이소미;노지희;이응직
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.17-24
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. Architecture considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully refelected from the early stage of BIPV module design. Trial product of BIPV module are manufactured and sample construction details for demonstration building are purposed. Therefore, this paper intends to advanced its practical use by proposing how to get integrated PV system which can be applied to prefab building material, and how to apply it.