• Title/Summary/Keyword: Integral Time Absolute Error

Search Result 28, Processing Time 0.017 seconds

Control of a pressurized light-water nuclear reactor two-point kinetics model with the performance index-oriented PSO

  • Mousakazemi, Seyed Mohammad Hossein
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2556-2563
    • /
    • 2021
  • Metaheuristic algorithms can work well in solving or optimizing problems, especially those that require approximation or do not have a good analytical solution. Particle swarm optimization (PSO) is one of these algorithms. The response quality of these algorithms depends on the objective function and its regulated parameters. The nonlinear nature of the pressurized light-water nuclear reactor (PWR) dynamics is a significant target for PSO. The two-point kinetics model of this type of reactor is used because of fission products properties. The proportional-integral-derivative (PID) controller is intended to control the power level of the PWR at a short-time transient. The absolute error (IAE), integral of square error (ISE), integral of time-absolute error (ITAE), and integral of time-square error (ITSE) objective functions have been used as performance indexes to tune the PID gains with PSO. The optimization results with each of them are evaluated with the number of function evaluations (NFE). All performance indexes achieve good results with differences in the rate of over/under-shoot or convergence rate of the cost function, in the desired time domain.

Optimization of PI Controller Gain for Simplified Vector Control on PMSM Using Genetic Algorithm

  • Jeong, Seok-Kwon;Wibowo, Wahyu Kunto
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.86-93
    • /
    • 2013
  • This paper proposes the used of genetic algorithm for optimizing PI controller and describes the dynamic modeling simulation for the permanent magnet synchronous motor driven by simplified vector control with the aid of MATLAB-Simulink environment. Furthermore, three kinds of error criterion minimization, integral absolute error, integral square error, and integral time absolute error, are used as objective function in the genetic algorithm. The modeling procedures and simulation results are described and presented in this paper. Computer simulation results indicate that the genetic algorithm was able to optimize the PI controller and gives good control performance of the system. Moreover, simplified vector control on permanent magnet synchronous motor does not need to regulate the direct axis component current. This makes simplified vector control of the permanent magnet synchronous motor very useful for some special applications that need simple control structure and low cost performance.

Decentralized $H_{\infty}$ Control of Multiple Magnetic Levitation System (다중 자기부상 시스템의 분산형 $H_{\infty}$ 제어)

  • Kim Jong-Moon;Lee Sang-Hyuk;Choi Young-Kiu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.12
    • /
    • pp.689-697
    • /
    • 2005
  • In this paper, an application of a decentralized $H_{\infty}$ controller(DHC) to multiple controlled-permanent magnet(CMAG) magnetic levitation(Maglev) systems is presented. The designed DHC using two Riccati equations iteratively has simpler structure and needs less computational loads than conventional centralized $H_{\infty}$ controller. A target plant is a hybrid-type CMAG system with permanent magnet and coil, and its mathematical model is firstly derived to design the DHC. To implement the designed algorithm, a real Maglev vehicle system including digital controller, chopper, sensor, etc., is manufactured. To compare the performances of the DHC method with an observer-based state feedback control(OSFC), the input tracking and disturbance rejection characteristics are experimentally tested. As performance indices(PI), integral of squared error(ISE), integral of absolute error(IAE), integral of time multiplied by absolute error(ITAE) and integral of time multiplied by squared error(ITSE) are used. From the experimental results, it can be seen that the input tracking and disturbance rejection performances of the DHC are better than those of the conventional controller.

Reduction of Fuzzy Rules and Membership Functions and Its Application to Fuzzy PI and PD Type Controllers

  • Chopra Seema;Mitra Ranajit;Kumar Vijay
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.4
    • /
    • pp.438-447
    • /
    • 2006
  • Fuzzy controller's design depends mainly on the rule base and membership functions over the controller's input and output ranges. This paper presents two different approaches to deal with these design issues. A simple and efficient approach; namely, Fuzzy Subtractive Clustering is used to identify the rule base needed to realize Fuzzy PI and PD type controllers. This technique provides a mechanism to obtain the reduced rule set covering the whole input/output space as well as membership functions for each input variable. But it is found that some membership functions projected from different clusters have high degree of similarity. The number of membership functions of each input variable is then reduced using a similarity measure. In this paper, the fuzzy subtractive clustering approach is shown to reduce 49 rules to 8 rules and number of membership functions to 4 and 6 for input variables (error and change in error) maintaining almost the same level of performance. Simulation on a wide range of linear and nonlinear processes is carried out and results are compared with fuzzy PI and PD type controllers without clustering in terms of several performance measures such as peak overshoot, settling time, rise time, integral absolute error (IAE) and integral-of-time multiplied absolute error (ITAE) and in each case the proposed schemes shows an identical performance.

Compensation of Position Error due to Amplitude Imbalance in Resolver Signals

  • Hwang, Seon-Hwan;Kwon, Young-Hwa;Kim, Jang-Mok;Oh, Jin-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.748-756
    • /
    • 2009
  • This paper presents a compensation algorithm for position error due to an amplitude imbalance between resolver output signals. Resolvers are typically used to obtain absolute position information for motor drive systems in severe environments. Position error is caused by an amplitude imbalance of the resolver output signals. As a result, the d- and q-axis currents of synchronous reference frame have periodic ripples in the stator fundamental frequency in permanent magnet synchronous motor (PMSM) drive systems. Therefore, this paper proposes a compensation algorithm to reduce the position error generated by the amplitude imbalance. The proposed method does not require any additional hardware, and reduces computation time with a simple integral operation according to rotor position. In addition, the position error can be directly compensated for by the estimated position error. The effectiveness of the proposed compensation algorithm is verified through several simulations and experiments.

Auto - tuning of PID Controllers with IMC Structure (IMC 구조를 갖는 PID 제어기의 자동 동조)

  • Cho, Joon-Ho;Hwang, Hyung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.8-14
    • /
    • 2009
  • In this paper, it is proposed that the design of the PID controller with the internal model control structure for improved performance. Internal model was identification that is second-order plus dead time structure using final-value theorem and genetic algorithm The parameters of Controller are determined to minimize IAE(Integral of the Absolute value of the Error) and ITAE(Integral of the Time multiplied by the Absolute value of the Error) of performance index by internal model and numerical method. Simulation examples are given to show the better performance of the proposed method than conventional methods.

An adaptive control algorithm for the speed control of hydraulic-servo system (유압 서보 시스템의 속도 제어를 위한 적응제어기의 설계에 관한 연구)

  • Yun, Ji-Seop;Jo, Hyeong-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.1
    • /
    • pp.29-39
    • /
    • 1986
  • An adaptive controller which is robust to the unknown load disturbance is developed for electro-hydraulic speed control systems. Since the load disturbance degrades the performance of the controller such as a steady state error and rise time in the conventional control system, appropriate adjustment of the controller is necessary in order to obtain the desired performances. The adaptation mechanism was designed to tune the feedforward gain, based upon minimization of ITAE (integral of time-multiplied absolute error) performance. The unknown load distrubance was identified by using an analog computer from the relationship between the velocity of the hydraulic motor and the load pressure. To evaluate the performance of the controller a series of simulations and experiments were conducted for various load conditions. Both results show that the proposed adaptive controller shows abetter performance than the conventional controller in terms of the steady state error and rise time.

  • PDF

Two-Parameter Optimization of CANDU Reactor Power Controller

  • Park, Jong-Woon-;Kim, Sung-Bae-
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.146-149
    • /
    • 1994
  • A nonlinear dynamic optimization has been performed for reactor power control system of CANDU 6 nuclear power plant considering xenon, fuel and moderator temperature feedback effects. Integral-of-Time-multiplied Absolute-Error (ITAE) criterion has been used as a performance index of the system behavior. Optimum controller gain are found by searching algorithm of Sequential Quadratic Programming (SQP). System models are referenced from most recent literatures. Signal flow network construction and optimization have been done by using commercial computer software package.

  • PDF

Optimization of a PI Controller Design for an Oil Cooler System with a Variable Rotating Speed Compressor (가변속 압축기를 갖는 오일쿨러의 최적 PI 제어기 설계)

  • Kwon, Taeeun;Jeong, Taeyoung;Jeong, Seokkwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.502-508
    • /
    • 2016
  • An optimized PI controller design method is presented to promote the control performance of an oil cooler system for high precision machine tools. First, a transfer function model of the oil cooler system with a variable rotating speed compressor was obtained by the perturbation method as the first order system with a negligible dead time. Then, the closed-loop control system was described as the second order system with a zero. Its dynamic behaviors are mostly governed by characteristic parameters, the damping ratio, and the natural frequency which is incorporated in PI gains. Next, an optimum integral of the time-weighted absolute error (ITAE) criterion was applied to the second order system. The characteristic parameters can be determined by the given design specifications, percent overshoots and settling times and comparisons with the ITAE criterion. Hence, the PI gains were plainly identified in a deterministic way. Finally, the PI gains were fine-tuned to obtain desirable dynamics in real systems, considering the zero effect and parameter variations. The validity of the proposed method was proven by computer simulations and real experiments for selected cases.

Design of Advanced Multi-loop PI Controller for Multi-delay Processes (다중 시간지연 공정을 위한 개선된 다중루프 PI 제어기 설계)

  • Vu, Truong Nguyen Luan;Lee, Moon-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2010
  • An analytical method for robust design of the multi-loop proportional-integral (PI) controller is proposed for various types of multi-delay processes. On the basis of the direct synthesis and generalized IMC-PID approach, the analytical tuning rules of the multi-loop PI controller are firstly derived for achieving the desired closed-loop response, and the structured singular value synthesis is then utilized for the tradeoffs between the robust stability and performance by adjusting only one design parameter (i.e., the closed-loop time constant). To verify the superiority of the proposed method, the simulation studies have been conducted on a wide variety of multivariable processes. The multi-loop PI controller designed by the proposed method shows a fast, well-balanced and robust response with the minimum integral absolute error (IAE) in compared with other renowned methods.