• Title/Summary/Keyword: Integral Controller

Search Result 726, Processing Time 0.025 seconds

Gain Tuning of a Fuzzy Logic Controller Superior to PD Controllers in Motor Position Control

  • Kim, Young-Real
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.3
    • /
    • pp.188-199
    • /
    • 2014
  • Although the fuzzy logic controller is superior to the proportional integral derivative (PID) controller in motor control, the gain tuning of the fuzzy logic controller is more complicated than that of the PID controller. Using mathematical analysis of the proportional derivative (PD) and fuzzy logic controller, this study proposed a design method of a fuzzy logic controller that has the same characteristics as the PD controller in the beginning. Then a design method of a fuzzy logic controller was proposed that has superior performance to the PD controller. This fuzzy logic controller was designed by changing the envelope of the input of the of the fuzzy logic controller to nonlinear, because the fuzzy logic controller has more degree of freedom to select the control gain than the PD controller. By designing the fuzzy logic controller using the proposed method, it simplified the design of fuzzy logic controller, and it simplified the comparison of these two controllers.

Fuzzy PD plus I Controller of a CSTR for Temperature Control

  • Lee, Joo-Yeon;So, Hye-Rim;Lee, Yun-Hyung;Oh, Sea-June;Jin, Gang-Gyoo;So, Myung-Ok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.563-569
    • /
    • 2015
  • A chemical reaction occurring in CSTR (Continuous Stirred Tank Reactor) is significantly affected by the concentration, temperature, pressure, and reacting time of materials, and thus it has strong nonlinear and time-varying characteristics. Also, when an existing linear PID controller with fixed gain is used, the performance could deteriorate or could be unstable if the system parameters change due to the change in the operating point of CSTR. In this study, a technique for the design of a fuzzy PD plus I controller was proposed for the temperature control of a CSTR process. In the fuzzy PD plus I controller, a linear integral controller was added to a fuzzy PD controller in parallel, and the steady-state performance could be improved based on this. For the fuzzy membership function, a Gaussian type was used; for the fuzzy inference, the Max-Min method of Mamdani was used; and for the defuzzification, the center of gravity method was used. In addition, the saturation state of the actuator was also considered during controller design. The validity of the proposed method was examined by comparing the set-point tracking performance and the robustness to the parameter change with those of an adaptive controller and a nonlinear proportional-integral-differential controller.

A New Improved Integral Variable Structure Systems for Uncertain Systems (새로운 개선된 적분 가변구조제어기)

  • 이정훈
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.253-257
    • /
    • 2000
  • A new improved variable structure controller is designed to drive uncertain linear systems to any given point by using a sliding surface with an integral of state error for removing any reaching phases. Predetermination or prediction of output response is feasible for all the persistent disturbances. The usefulness of the proposed algorithm is verified through an illustrative example.

  • PDF

Speed Control of Induction Motor Using Anti-windup Integral-Proportional Controller (반포화 적분-비례제어기를 이용한 유도전동기의 속도제어)

  • 정재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.215-218
    • /
    • 2000
  • The windup phenomenon appears and degrades control performance when a controller with integrating action is used and the plant input is limited. An anti-windup integral -proportional(IP) controller is proposed for the variable-speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated (PWM) voltage source inverter(VSI). Although the operating conditions like motor load and speed command is changed under the limited plant input it is experimentally verified that the speed response has much improved performance such as no overshoot and fast settling time and the maximum plant input is also effectively utilized.

  • PDF

Effect of feedback on PID controlled active structures under earthquake excitations

  • Nigdeli, Sinan Melih
    • Earthquakes and Structures
    • /
    • v.6 no.2
    • /
    • pp.217-235
    • /
    • 2014
  • In this paper, different feedback control strategies are presented for active seismic control using proportional-integral-derivative (PID) type controllers. The parameters of PID controller are found by using an numerical algorithm considering time delay, maximum allowed control force and time domain analyses of shear buildings under different earthquake excitations. The numerical algorithm scans combinations of different controller parameters such as proportional gain ($K_p$), integral time ($T_i$) and derivative time ($T_d$) in order to minimize a defined response of the structure. The controllers for displacement, velocity and acceleration feedback control strategies are tuned for structures with active control at the first story and all stories. The performance and robustness of different feedback controls on time and frequency responses of structures are evaluated. All feedback controls are generally robust for the changing properties of the structure, but acceleration feedback control is the best one for efficiency and stability of control system.

Design of a Position Control System for Electro-hydraulic Motors (전기유압식 모터용 위치제어 시스템의 설계)

  • 박진길;진강규;노영오;한봉주;정주윤;박재식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.30-41
    • /
    • 1992
  • For the state feedback controller which measures only partial state variables, a state observer can be used to give the estimates of unmeasurable states. In this paper, the delayed state feedback method instead of the state observer for desingning a tracking controller of electro-hydraulic control system is presented. The controller design is based on augmenting the original system by one additional integral and proportional element which compensates for the effect of the integral control and on feeding back the measurable state variables and their delayed values. The performance of the proposed position control system is compared with both that of the full state feedback control system and that of the digital PID control system tuned by the Ziegler-Nichols method and by the parameter readjustment through the computer simulation. And then robustness against unmeasurable constant disturbace and parameter variations during operations is also checked.

  • PDF

The Robust Servo Controller Design of Magnetic Levitation System Considering Pole Assignment Region (극 배치영역을 고려한 자기 부상계의 로버스트 서보제어기 설계)

  • Kim, C.H.;Jeong, H.J.;Yang, J.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.84-91
    • /
    • 2000
  • This paper describes a state feedback controller design method of the integral type magnetic levitation servo system which satisfies the design objectives. The design objective is a $H_{\infty}$ performance, asymptotic disturbance rejection and a robust pole assignment in linear matrix inequality(LMI) region. To the end, we investigated the validity of the designed controller which considering a robust pole assignment region, through results of simulation.

  • PDF

A New Robust Output Feedback Variable Structure Controller for Uncertain More Affine Nonlinear Systems with Mismatched Uncertainties and Matched Disturbance

  • Lee, Jung-Hoon
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.206-213
    • /
    • 2014
  • In this note, a new robust nonlinear output feedback variable structure controller is first systematically and generally designed for the output control of more affine uncertain nonlinear systems with mismatched uncertainties and matched disturbance. A transformed integral output feedback sliding surface with a most simple form is applied in order to remove the reaching phase problems. The closed loop exponential stability and the existence condition of the sliding mode on the integral output feedback sliding surface is investigated with a corresponding output feedback control input in Theorem 1. For practical application the continuous implementation of the control input is made by the modified saturation function. The effectiveness of the proposed controller is verified through a design example and simulation study.

Temperature Control of Superheater Steam in Thermal Power Plant (화력발전소의 과열기증기의 온도제어)

  • Shin, Hwi-Beom;Lee, Soon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2006-2011
    • /
    • 2010
  • The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.

Nonlinear Friction Compensation using the Information of Integral Controller (적분 제어기 정보를 이용한 비선형 마찰보상)

  • 송진일;최용훈;유지환;권동수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.110-119
    • /
    • 2000
  • This paper presents simple and effective nonlinear friction compensation methods. When the direction of position command reverses, the integrator output of the PID controller does not change the sign of its output instantaneously, due to friction at zero velocity, i.e. stiction resulting tracking errors, that results in continuous push even though the command direction has been changed. To overcome this problem, we attempt to reverse the sign of the integrator output as the sign of velocity changes. The effectiveness of this approach is demonstrated by experiments on a 3-PRPS (Prismatic-Revolute-Prismatic-Shperical joints) in-parallel 6-D.O.F manipulator. The control strategy has been analyzed for stability. Also discussed are disturbance observer and velocity observer approaches for friction compensation.

  • PDF