• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.036 seconds

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Aging Properties from Forest-fire Simulated Acceleration of Porcelain Insulators for Transmission Line (송전용 애자의 산불 복합가속열화 특성)

  • Han, Se-Won;Choi, In-Hyuk;Lee, Dong-Il;Lee, Won-Kyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.114-114
    • /
    • 2010
  • 산불에 노출되는 경우 열충격으로 작용하는 패턴과 특성을 검토하여 가속열화시험에 반영하는 것이 필요하다. 본 연구에서는 산불환경을 모의하여 복합열화시험을 실시하기위해 복합가속열화 챔버를 구축하였다. 온도는 주로 $200^{\circ}C$에서 최대 $1000^{\circ}C$까지 변화를 주면서 예비시험과 본시험 실하였다.

  • PDF

Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation (전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Joe, Sung-Hoon;Yoon, Jae-Hoon;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

The Study on the Character of Pyrolysis of Polymeric Insulators (폴리머 애자의 열분해 특성에 관한 연구)

  • Park, Chul-Bae;Chun, Sung-Nam;Lee, Byung-Sung;Min, Dong-Ye
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.84-85
    • /
    • 2009
  • 전력기술의 발전함에 따라 절연소재 또한 급속한 발전을 가져왔다. 특히, 오랫동안 사용해온 자기재 절연물에서 시공의 용이성, 경량성, 내오염성 등과 같은 장점을 가진 폴리머 절연물로 대체 되어 사용되어져 왔다. 폴리머 애자는 1980년대 말에 최초로 사용되기 시작 하여 2007년 한 해 동안 약 100만여개의 폴리머 애자가 배전선로에 사용되고 있다. 이러한 폴리머 절연재료는 그 수명이 20년 으로 보고되어지는바, 그 수명이 종기인 현재 폐기되는 폴리머양은 점차적으로 증가할 것으로 보여진다. 본 논문에서는 이러한 폴리머 폐기물의 처리를 위한 열분해 특성에 관한 것으로 향후에 효율적인 폴리머 절연폐기물의 처리를 위한 기초 자료로 활용하고자 한다.

  • PDF

Development of a Measuring Instrument of Current and Voltage on Power-Transmission Lines for the Construction of Energy-Network

  • Park, Kyi-Hwan;Jiang, Zhongwei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.107.2-107
    • /
    • 2001
  • We propose portable equipment that monitors a current and potential on high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to a hollow insulator that supports a power transmission line: A current on a power line is detected by an air-core solenoidal coil clamped to the line and the detected current signal is transmitted to the ground station by using optical data link, A potential on a power transmission line is detected by a high resistance element, zinc oxide (ZnO) that acts as a potential divider between the power line and the ground. The equipment does not require high potential insulators and magnetic cores which. This leads to the following advantages of the equipment: (a) It is easily installed owing to its small size and its simple structure; (b) It operates in low ...

  • PDF

Conditional Event Matching Prediction of Nonlinear Phenomena of Insulator Pollution in Coastal Substations Based on Actual Database

  • Nakamura, Masatoshi;Goto, Satoru;Katafuchi, Tatsuro;Taniguchi, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.157-160
    • /
    • 1999
  • A prediction method of conditional event matching pre-diction (EMP) for a purpose of predicting nonlinear phenomena of insulator pollution was proposed in this paper. The EMP was used if the conditional probability for increase of insulator pollution exceeded a threshold value. A performance of the EMP was strongly related to selection of database of events and a closeness function. By use of the prediction of the insulator pollution based on the conditional EMP, reliable decision making for the washing timing of the polluted insulators was e-valuated based on actual data in Kasatsu substation, Japan.

  • PDF

Low Temperature Synthesis of Willemite Powder (Willemite 분말의 저온합성)

  • Son, Se-Gu;Lee, Ji-Hyeon;Lee, Jeong-Mi;Kim, Young-Do
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.7
    • /
    • pp.401-404
    • /
    • 2008
  • Willemite ($Zn_2SiO_4$) are a wide range of applications such as a phosphor host and an important crystalline phase in glass ceramics, electrical insulators, glazes, and pigments. In this study, Willemite precursors were synthesized with zinc silicate gels from mixture of zinc nitrate solution and various sodium silicate solution by the geopolymer technique. To examine the crystallization behavior, precursors were have been monitored by the XRD. A pure willemite phase was obtained at $900^{\circ}C$. TEM investigations revealed that the sample with 50 nm particle size was obtained via heat-treated at $900^{\circ}C$ for W-3.

Characteristics of Sulfide Treated GaAs MISFETs with Photo-CVD Grown $P_3$$N_5$ Gate Insulators (유화처리와 광CVD법 질화인막을 이용한 GaAs MISFET 특성)

  • 최기환;조규성;정윤하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.9
    • /
    • pp.72-77
    • /
    • 1994
  • GaAs MISFETs, with photo-CVD grown P$_{3}$N$_{5}$ gate insulator and sulfide treatment, have been fabricated and showed the instability of drain current reduced less than 22 percent for the period of 1.0s~1.0${\times}10^{4}s$. The effective electron mobility and extrinsic transconductance of the device are about 1300cm$^{2}$/V.sec and 1.33mS at room temperature. The C-V characteristics of GaAs MIS Diode and AES analysis are also discussed with respect to effect of sulfide treatment conditions.

  • PDF

The aging test method of insulator and development prospect of polymer insulator (배전용애자의 경년시험방법과 폴리머애자의 개발 동향)

  • Song, I.K;Kim, S.J.;Kim, J.Y.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1791-1793
    • /
    • 1996
  • This paper describes Thermal-Mechanical performance and Ultimate Mechanical-Strength test for the purpose of aging analysis of suspension insulator. The temperature difference of insulator surface according to the aging of suspension insulator brought out about $2^{\circ}C$ to $7-8^{\circ}C$ difference comparing with the atmospheric temperature. Quality standard and Mechanical-Strength of used suspension insulator deteriorate more remarkably than that of new suspension insulator. It is required that Thermal-Mechanical performance test standard be revised in the future. And it is described about the development prospect of polymer insulators

  • PDF