• 제목/요약/키워드: Insulators

Search Result 652, Processing Time 0.034 seconds

Electrical Characteristics of Pentacene-based TFTs with Stacked Gate Dielectrics

  • Kang, Chang-Heon;Park, Jae-Hoon;Lee, Yong-Soo;Kim, Yeon-Ju;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.653-655
    • /
    • 2003
  • Using stacked organic gate insulators and active layer of pentacene deposited at elevated temperatures, pentacene-based organic thin-film transistors(OTFTs) with improved electrical characteristics have been fabricated. Stacked PVP(Polyvinylphenol)-polystyrene gate insulators could compensate the demerits and take advantage of the merits of each other [1]. Also, for the better device performance, moderate substrate heating and high deposition rate of pentacene active layer was adopted [2, 3].

  • PDF

Properties of Poly-Si TFT's using Oxide-Nitride-Oxide Films as Gate Insulators (Oxide-Nitride-Oxide막을 게이트 절연막으로 사용하여 제조한 다결정실리콘 박막트랜지스티의 특성)

  • 이인찬;마대영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1065-1070
    • /
    • 2003
  • HTO(High Temperature Oxide) films are mainly used as a gate insulator for polysilicon thin film transistors(Poly-Si TFT's). The HTO films, however, show the demerits of a high leakage current and a low electric breakdown voltage comparing with conventional thermal oxides even though they have a better surface in roughness than the thermal oxides. In this paper, we propose an ONO(Oxide-Nitride-Oxide) multilayer as the gate insulator for poly-Si TFT's. The leakage current and electric breakdown voltage of the ONO and HTO were measured. The drain current variation of poly-Si TFT's with a variety of gate insulators was observed. The thickness optimization in ONO films was carried out by studying I$\_$on/I$\_$off/ ratio of the poly-Si TFT's as a function of the thickness of ONO film adopted as gate insulator.

Pollution Cycle Method with NSDD Contaminant (불용성 오손물을 이용한 오손주기시험법)

  • Lee, Won-Yeong;Choi, Nam-Ho;Park, Gang-Sik;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1481-1483
    • /
    • 2001
  • There is a wide climatic difference between Korea and foreign countries. Thus, the pollution cycle method, based on the climatic condition of Korea, is needed to evaluate the electrical properties of outdoor insulators. We make a analysis on the cycle methods of foreign countries, climatic conditions of Korea and failure data to make the cycle method. From the result, we can design a good pollution cycle method to evaluate the electrical properties of outdoor insulators.

  • PDF

Information Propagation Neural Networks for Reduction of Power-Loss (전력손실 감소를 위한 정보전파응용구조 신경회로망)

  • Kim, Jong-Man;Kim, Won-Sup;Lim, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2546-2549
    • /
    • 2004
  • For Reduction of Power-Loss, a new Lateral Information Propagation Networks(LIPN) has been proposed. Damaged insulator is reduced the rate of insulation extremely, and taken the results dirty and injured. It is necessary to be actions that detect the damaged insulator and exchange the new one. And thus, we have designed the LIPN to be detected that insulators by the real time computation method through the inter-node diffusion. In the network, a node corresponds to a state in the quantized input space. Each node is composed of a processing unit and fixed weights from its neighbor nodes as well as its input terminal. Information propagates among neighbor nodes laterally and inter-node interrelation is achieved. Through the results of simulation experiments, we difine the ability of real-time detecting the damaged insulators.

  • PDF

Analysis on the Degradation of Insulators using Corona Camera (코로나 카메라를 이용한 불량애자 검출사례 분석)

  • Kim, H.S.;Kim, P.H.;You, Y.K.;Koo, K.W.;Kim, H.J.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

The Development of Gas Bushing for 72.5kV/1200 GCB and GIS (72.5kV/1200A 차단기 및 GIS용 개스 붓싱 개발)

  • Kim, J.B.;Song, W.P.;Lee, C.H.;Noh, C.W.;Choi, J.Y.;Jang, W.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.249-252
    • /
    • 1993
  • On Concerning to the Bushing for the High Voltage Transformer and GCB & GIS which we have imported of all type owing to the insufficiency of internal production facilities and the want of technology, our research team succeeded in the development of the 72.5kV/1200A Gas Bushing for GCB & GIS. We carried out the dimensions & visual tests and the mechanical & electrical tests, and we have got the favorable test-results.

  • PDF

Selection of Sound Insulation Structure of Air-conditioner Compressor by Measurement of Sound Power (음향파워 측정에 의한 에어컨 컴프레서의 차음 구조 결정)

  • 이진교;김진섭;모진용;박득용;김봉준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.197-202
    • /
    • 2001
  • The compressor is one of major noise sources in air conditioner outdoor units, especially deteriorating the sound quality. Therefore, the sound insulation materials layered with sound absorption materials are applied around compressors. In this study, the performance of the sound insulators is examined by measuring the insertion losses in power base and the effects of sound absorption materials, method of application and the shape of the insulators are also investigated. The importance of minimizing the opening is revealed well.

  • PDF

Suspension insulator development of Epoxy casting Bar-Type (에폭시 BAR-TYPE 배전용 현수애자 개발)

  • Kim, J.Y.;Song, I.K.;Kim, S.J.;Kwon, D.J.;Kim, S.K.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1529-1531
    • /
    • 1996
  • Porcelain suspension insulators have teen used for a long time in distribution line. However, Puncture breakdowns in porcelain insulators caused by weaking cement between metal fitting nad porcelain material. There is little puncture breakdown in Epoxy casting insulator. This paper presents electrical test results for the development of suspension insulator used Cycloaliphatic Epoxy resin. Items of test results are as follow - Power Arc test - Aging test - Impulse flashover voltage tests - Puncture tests et.al.

  • PDF

A Study on the Breakage Causes of Toughened Glass Stem Insulators (유리애자 파손원인에 대한 고찰)

  • Jung, Jong-Wook;Jung, Jin-Soo;Shong, Kil-Mok;Kim, Young-Seok;Kim, Sun-Gu;Lim, Dong-Hoon;Ryu, Young-Tae;Jeon, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1201-1202
    • /
    • 2008
  • This paper describes what causes the breakage of the toughened glass stem insulators. Several plausible hypotheses were proposed by surveying the field, hearing evidence, analyzing the broken specimens, etc. The hypotheses were classified into a couple of patterns and the hypotheses were selected and listed in order of the possibility. As a result, the most convincing cause of the breakage was the resonance of the vibrations incoming from the H-frame side and the feeder side. In addition, the collision of ballasts and the impurities in the toughened glass could be also the causes.

  • PDF

Surface Discharge and Materials Analysis of Polymer Insulators Due to Accelerated Deterioration (가속열화에 의한 폴리머애자의 연면방전과 재료분석)

  • Shong, Kil-Mok;Kim, Jong-Min;Jung, Jin-Su;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1372-1373
    • /
    • 2008
  • This study investigated the detection of corona discharge on polymer insulators at 13.2kV. Also, It will be analyzed by variety analyzers such as FT-IR, TA, and so on. It carried out an experiment and an actual measurement about corona detection using a UV-camera. This experiment and inspection would need to respect the above criteria. It was required to verify various experimental conditions and on-site inspection afterwards, but it was believed to minimize the measurement error by data-basing research results in a continuous manner and it was necessary to establish diagnosis technologies and standards in various electrical power facilities.

  • PDF