• Title/Summary/Keyword: Insulation property

Search Result 272, Processing Time 0.032 seconds

Electrical and Mechanical Properties for Micro-and-Nano Mixture Composites using Electric Field Dispersion Technique (전기장 분산기술을 이용한 에폭시 마이크로-나노 입자가 혼합된 콤포지트의 전기적 그리고 기계적특성)

  • Cho, Dae-Lyoung;Han, Jin-Hee;Kim, Jung-Joong;Kim, Jung-Hoon;Yoo, Byoung-Bok;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.98-98
    • /
    • 2010
  • A epoxy/multilayered silicate nanocomposite was prepared by a new AC electric application method and micro silica particle was poured into the nanocomposite in order to prepare epoxy/micro-and-nano- mixed composites (EMNC). Electric insulation breakdown strength was measured in a sphere-sphere electrode system designed for the prevention of edge breakdown and the data were estimated by Weibull plot. As the exfoliated silicate nano-plates were homogeniously dispersed in the micro silica particles, the insulation property was higher.

  • PDF

A Study on Thermal Properties for Epoxy Micro-and-Nano Mixture Composites(EMNC) (에폭시 마이크로-나노 입자가 혼합된 콤포지트의 열적특성에 관한연구)

  • Lee, Chang-Hoon;Kim, Kuk-Jin;Kim, Suk-Man;Kang, Do-Hoon;Yeon, Da-Som;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.83-83
    • /
    • 2010
  • This study investigates the thermal and mechanical properties of insulation elements through mixing epoxy based micro- and nano particles. Regarding thermal properties, DSC and DMA were used to calculate crosslinking densities for various types of insulation elements. In a mechanical property of bending strength, shape and scale parameters were obtained using the Weibull plot. This study obtained the most excellent results of scale parameters, such as Vol 3.2%, in the bending strength of EMNCs.

  • PDF

Heat Insulation Properties of Lightweight Magnesia Matrix According to Mixing Ratio of Anthracite (안트라사이트 치환율에 따른 경소마그네시아 경화체의 단열특성)

  • Pyeon, Su-jeong;Gwon, Oh-han;Kyoung, In-soo;Lee, Dong-hoon;Lee, Sang-soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.113-114
    • /
    • 2017
  • Recently, Subway workers have died from lung cancer. According to the Epidemiological Survey of the Welfare Corporation Institute of Pulmonary Disease of the Welfare Corporation, the family members applied for industrial accidents. The radon concentration in the subway work area was found to exceed 10 times the recommended standard value of 148 becquerels (Bq/㎥) in domestic multipurpose facilities. In addition, as a result of the national indoor radon concentration survey conducted by the Ministry of Environment in 2010 and 2013, housing was found to be over 100 becquerels (Bq/㎥) in 41% of the surveyed subjects. In addition, it was found that in 2012, 16.3% of villages exceeded the radon standard value in the survey on natural radioactive materials containing groundwater.

  • PDF

Stimulus transfer properties of Au/Arac. acid/Al structure (Au/Arac. acid/Al 구조의 자격전달특성)

  • 송진원;최영일;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.491-494
    • /
    • 1999
  • We have examined the electrical properties of arachidic acid Langmuir (L) films by using a displacement current measuring technique with pressure stimulation. We give pressure stimulation into organic thin films and detect the Induced displacement current. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers are 17, 19 and 21. Also, we then examined of the MIM device by means of I-V The I-V characteristic of the device is measured from 0 to +1[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

Analysis of dielectric and insulation characteristics of elastic epoxy resin according to elastomer contents for power machines (전력용 탄성형 에폭시의 유전 및 절연 특성 해석)

  • Kim, Seok-Jae;Park, Seong-Hee;Lim, Kee-Joe;Lee, Ki-Tae;Kang, Seong-Hwa;Park, Dea-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.230-232
    • /
    • 2004
  • In this paper, we investigated dielectric and insulation characteristics of epoxy resin which includes elastomers to improve mechanical property, as varied additive elastomer contents with 5[phr], 10[phr], 15[phr], and 20[phr]. We measured permittivity and tan $\delta$ at 1kHz of signal frequency and room temperature. And we also measured BVD(break-down voltage) and volume resistivities. According to the experimental results, it is appeared that when the additive elastomer contents are increasing, permittivity, volume resistivity, BVD and volume resistance are decreasing because elastomer remains inferior to epoxy resin on electrical properties.

  • PDF

Effects of Freshwater Flooding on the Properties of the Accelerated Thermally Aged CSPE (가속열화 된 CSPE의 특성에 미치는 담수침지의 영향)

  • Kang, Myeong-Gyun;Lee, Jung-Hoon;Lee, Seung-Hoon;Jeon, Jun-Soo;Kim, In-Yong;Shin, Yong-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.367-370
    • /
    • 2014
  • The accelerated thermal aging of a CSPE were carried out for 0, 80.82, 161.63 days at $100^{\circ}C$, which are equal to 0, 40 and 80 years, respectively. The volume electrical resistivities of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were $9.620{\times}10^{12}{\sim}1.246{\times}10^{13}{\Omega}{\cdot}cm$, $5.066{\times}10^{12}{\sim}7.576{\times}10^{12}{\Omega}{\cdot}cm$ and $7.195{\times}10^{12}{\sim}9.208{\times}10^{12}{\Omega}{\cdot}cm$ at room temperature, respectively. The dielectric constant of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were 3.355~4.030, 2.996~3.963 and 3.020~4.776 at room temperature, respectively. After seawater and freshwater flooding, the volume electrical resistivity of the CSPE trend slightly upward according to drying day at room temperature. After seawater flooding, the dielectric constant of the accelerated thermally aged CSPE were not measured. After seawater flooding, bright open pores of the accelerated thermally aged CSPE were partly transferred to dark close pores due to salinity. After freshwater flooding, dark close pores of the accelerated thermally aged CSPE were partly transferred to bright open pores because salinity of them is decreased. An insulation property of a cable in NPPs was decreased because of the seawater flooding, and an insulation property of them was recovered through the freshwater flooding. As a result, it is considered that an insulation property of a contaminated cable through Tsunami can be recovered if it is cleaned quickly.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Characterizations on the Thermal Insulation of SiC Coated Carbon-Carbon Composites (탄화규소로 코팅된 탄소-탄소 복합재료의 단열 특성)

  • Seo, Hyoung-IL;Lim, Byung-Joo;Sihn, Ihn Cheol;Bae, Soobin;Lee, Hyung-Ik;Choi, Kyoon;Lee, Kee Sung
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.101-107
    • /
    • 2020
  • This study investigates the characterization on the thermal insulation properties of silicon carbide coating on the Cf-C composites. The silicon carbide coatings by chemical vapor deposition on the C/C composites are prepared to evaluate thermal resistance. Firstly, we perform the basic insulation test by thermal shock at 1350℃ in air on the C/C composite and SiC-coated C/C composite. We also performed the burner tests on the surface of the composites at high temperatures such as 1700 and 2000℃, and the weight change after burner tests are measured. The damages on the surface of C/C composite and SiC-coated composite are observed. As a result, the SiC coating is beneficial to protect the C/C composite from high temperature even though damages such as defoliation, crack and voids are observed during burner test at 2000℃.

A Study on the Improvement of Cold Protective Clothing for Mailman (우편배달원 방안복 개선을 위한 연구)

  • Kwon, Myoung-Sook;Seok, Hye-Jung
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.8
    • /
    • pp.14-23
    • /
    • 2007
  • The purpose of this study was to investigate the present condition of cold protective clothing for mailman, to improve its design in movement, fitness, and other functions, and supply basic data for its performance evaluation. The results are as follows : The 46.60% of those questioned did not satisfy current clod protective clothing fer mailman. Especially, they considered dissatisfactory in properties such as waterproof, comfort, activity, and sweat absorption. The newly developed cold protective clothing is two-piece style composed of jacket and pants. Both jacket and pants are composed of inner and outer clothing individually. In both jacket and pants, their outer clothing's material was waterproof, windproof, and breathable shell fabric on which PTFE film laminated and their inner clothing's material was 100% polyester Polar polis to have better insulation property. The jacket has attachable cap which can be used as rain gear and set-in sleeve with stand collar. It also had big outside patch pockets and side seam pockets to ensure enough storage space. The pants have knee pads to give free movement to knees and slant side pockets. Inner clothing of both jacket and pants can be worn during working inside without out clothing. Insulation of the newly developed cold protective clothing was not better than current one except right hand, left hand and left foo. It is considered that is because thickness of material is the most important factor to influence insulation.

A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges (공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구)

  • Kim, Dong Su;Yoon, Jong Ho;Shin, U Cheul;Kwak, Hee Yul
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.