• Title/Summary/Keyword: Insulation method

Search Result 1,176, Processing Time 0.047 seconds

Other Changes in Bond Strength due to External Insulation Method (외단열 고정 방법에 따른 부착강도 변화)

  • Kim, Tae-Jun;Park, Wan-Goo;Park, Jin-Sang;Oh, Jung-Hwan;Bae, Ki-Sun;Oh, Sang Geun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.132-133
    • /
    • 2013
  • External Insulation Method is to place the insulation on the outside of concrete. External Insulation Method is better than Internal Insulation Method to the protection of structure. However, The phenomenon that External Insulation falling from the structure occurs frequently. Apply method of External Insulation is divided Wet Construction, Dry Construction and Wet & Dry Construction. The purpose of this study is to test Bonding Strength of External Insuation. Furthermore, on the basis of this study, External Insulation Method determines the effective development will be made.

  • PDF

Problem Analysis of Sandwich Insulation Wall System (중단열 시스템의 문제점 분석)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.166-167
    • /
    • 2015
  • Because of energy crisis at all around the world, there is many method and system which for improving energy efficiency has appeared in construction industry. And then, 20% of entire building energy loss is emissed to exterior of buildings, that is important to building's entire energy efficiency. So, many research has been conducted for imporve exterior energy efficiency and generally it called insulation of wall. Method for wall insulation can be classified interior system and exterior system which defined installation place of insulation board whether interior or exterior of structural wall. However, interior system has thermal problem such as thermal-bridge which can be necessarily occur condensation. and exterior system has constructional problem such as difficult to construction because exterior and finish work so expensive construction cost than other insulation method. Thus, sandwich insulation wall system has been appeared for solving these problems. Sandwich insulation system must using wall connecting things because both side walls is divided by center insulation. At this, Through the heat at wall connecter, it can be occured thermal-bridge and broken insulation board when under construction will be bring negative effect by reducing wall thickness and insulation deficit. At this study, we were compared previous sandwich insulation system and analysis these system's problem for develop the improving constructability and performance of sandwich insulation system.

  • PDF

A Study on the domestic power plant roof waterproofing system & insulation efficiency (국내 발전소 지붕방수설계 시스템 및 단열 성능에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • As the development of construction technology and new materials, building requirements has been varied gadually. Comfortable environment and serviceability of production activity and energy conservation are being dealt with very seriously. Recently localization of engineering technology of Power Plant, however, construction materials and domestic technology are being developed forcingly. According to above topics this thes is going to study roof waterproofing, thermal insulation and evaluate adiabatic performance and evaluation of properties of waterproofing materials and energy conservation. The results of studying and evaluating of roof waterproofing, thermal insulation and adiabatic performance of Power Plant are as follows. 1. Sheet waterproofing method is better than that of asphalt waterproofing method in that adaptability of wearhertight, thermal resistant, contraction and expansion. 2. It is required to replace polyurethane or ethylene used as thermal insulation with rock wool which is noncombustible materials. 3. It is recommended to usd outer insulation method than inner insulation method due to superioty of outer insulation method. Efficiency of insulation materials used in power plant is generally good except perlite mortar used in the power plant(YGN 1-2, GRI 1-2).

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF

An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window (현장에서의 창의 차음성능 측정방법에 관한 실험적 연구)

  • Lee, Ok-Kyun;Park, Hyeon-Ku;Choi, Hyung-Wook;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method (동적 시정수 기반 고성능 절연 저항 계산 기법)

  • Son, Gi-Beom;Hong, Jong-Phil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.8
    • /
    • pp.1058-1063
    • /
    • 2020
  • This paper presents a new insulation resistance calculation technique to prevent electric shock and fire accidents due to the dielectric breakdown in the primary insulation section of the IT ground system. The solar power generation market is growing rapidly due to the recent expansion of renewable energy and energy storage systems, but as the insulation is destroyed and fire accidents frequently occur, a device for monitoring the insulation resistance state is indispensable to the IT grounding method. Compared to the conventional algorithm that use a method of multiplying a time constant to a fixed coefficient, the proposed insulation resistance calculation method has a fast response time and high accuracy over a wide insulation resistance range by applying a different coefficient according to the values of the insulation impedance. The proposed dynamic time constant based insulation resistance calculation technique reduces the response time by up to 39.29 seconds and improves the error rate by 20.11%, compared to the conventional method.

Insulation Performance Evaluation of Apartment Housing Using Infra-red Camera (적외선 열화상을 이용한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.718-723
    • /
    • 2009
  • The purpose of this study is to present an in-site evaluation method for building insulation performance using Infra-red camera. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature & heat flow pattern analyze method. By establishing the in-site evaluation method building insulation performance using infra-red camera, it is expected that 1) building envelope repair market will be activated by using developed method in ESCO and remodeling companies, 2) the method developed in this research will contribute to reduce national energy consumption by promoting old building insulation remodeling.

  • PDF

Insulation Performance Evaluation for Waterproofing Materials that Uses Air Cap Sheet (에어캡시트를 이용한 단열 보완형 방수공법의 단열성 평가)

  • Ma, Seung Jae;Lee, Jong Yong;Choi, Sung Min;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.175-176
    • /
    • 2015
  • Insulation in buildings are one of the crucial factors for energy reduction, and depending on the application areas and properties of the insulation requirements, various different types of insulation materials are being developed, produced, and used. Amongst these is the aircaps often used as packing materials. Because of their porous nature, they are highly efficient in preventing heat and are consequently used overseas often as insulation materials and as part of cold water concrete insulation curing method. This paper studies the recently developed usage of aircaps in waterproofing materials and evaluated their performance as supplementary insulation materials.

  • PDF

Strength Properties of Multi-layered Insulation according to the Type of Configuration (다층형 단열재의 구성 형식에 따른 강도 특성 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF

A Research on Suggestion of Proper Adhesion Strength about conjugation Method of outside Insulation. (외단열 고정 방법에 따른 적정 접착강도 제안에 관한 연구)

  • Park, Wan-Goo;An, Ki-Won;Park, Jin-Samg;Park, Ku-Byoung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.93-94
    • /
    • 2012
  • Recently outside insulation is applied on the building. Adhesion mortar and anchor are used fixing method of outside insulation. However, a research on proper Adhesion Strength is not performed. So outside insulation exfoliate from building in rainy with winds. Therefore, this research suggest proper adhesion strength about conjugation method of outside insulation. As a result, adhesion way using the adhesive mortar + anchor is best. And proper adhesion strength is over 1,065 N.

  • PDF