• Title/Summary/Keyword: Insulation level

Search Result 342, Processing Time 0.022 seconds

Comparison of Insulation Coordination Between ±800kV and ±1100kV UHVDC Systems

  • Wang, Dong-ju;Zhou, Hao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1773-1779
    • /
    • 2015
  • Insulation coordination is a key problem in UHVDC systems in terms of safety and cost. Although high-voltage ±1100kV UHVDC projects are being planned in China, the characteristics and key points of high-voltage systems have not yet been analyzed. This study aims to improve the safe, effective operation of these high-voltage power transmission systems. First, we analyzed two typical insulation coordination schemes used in ±800kV UHVDC systems in China. Next, we used the two typical ±800kV insulation coordination schemes as a reference to analyze the ±1100kV UHVDC system. Finally, we compared these schemes and proposed an effective insulation coordination solution, as well as developing principles for ±1100kV UHVDC systems. Our findings indicate that the points enduring the highest voltage in the system should be protected separately by special arresters. Our analysis of the insulation coordination of ±800kV and ±1100kV UHVDC systems concluded that, in ±1100kV UHVDC systems, the main goal of insulation coordination is to lower the insulation level of points enduring the highest voltage. However, in a ±800kV UHVDC system, the main goal is to reduce the cost of manufacture for arresters, as well as the space occupation in the valve hall, with an acceptable insulation level.

A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing (공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구)

  • 손철수
    • Journal of the Korean housing association
    • /
    • v.11 no.1
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

A Consideration on the Establishment of Standard level for Floor Impact Sound Insulation (바닥충격음 차단성능 기준설정 고찰)

  • 송민정;기노갑;장길수;김흥식;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.226-229
    • /
    • 2001
  • Recently the impact sound insulation performance is regarded as one of the most import factors in determining the quality of housing environment. In order to reduce the impact sound level transmitted through the floors and structures, establishing the standard level of impact sound insulation performance is needed. In this consideration, The effecting facts for the standard insulation level is reviewed.

  • PDF

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex (공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사)

  • Seong, Yo-Han;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

A Study on the Sound Insulation performance Survey Estimation in Apartment house (공동주택의 소음성능 실측평가에 관한 연구)

  • 함진식;박명길
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test (실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구)

  • Kim, Hang;Park, Hyeon Ku;Ku, Hee Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance (바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구)

  • 장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF

A Study on the Evaluation of Sound Insulation Performance of Double Skin Facade -Focus on the Multi-story type of Double Skin Facade- (이중외피시스템의 차음성능 평가에 관한 연구 -전면형 이중외피시스템을 중심으로-)

  • 석호태;차민철
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • The purpose of this study is to evaluate the sound insulation performance and present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-story type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.