• 제목/요약/키워드: Insulation Paper

검색결과 1,586건 처리시간 0.034초

설비용 단열재 난연성 평가 현황과 개선 방안 (A Study on Incombustibility of Building Service System Insulation Material)

  • 박종일;김석현;홍진관;이민우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.999-1005
    • /
    • 2006
  • The aim of this paper is to evaluation survey and improvement method of building service system insulation material incombustibility. In Korea, various insulation materials are being used to prevent energy losses. Performance of insulation materials is gradually advanced, and new insulation materials are developed and being used. We don't have prefer test standard of insulation material incombustibility. In this paper we investigate domestic and foreign standard about incombustibility Through the authors will show how we can improve incombustibility test standard in Korea.

  • PDF

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상 (Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF

액체질소에서 절연지 및 mini-model 케이블의 전기절연 특성 (The Electric Insulation Characteristics of the Insulation Paper and Mini-model Cable in Liquid Nitrogen)

  • 곽동순;김영석;정종만;김해종;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.224-227
    • /
    • 2003
  • According to the increasing power demands for the power transmission of major cities, HTS power cables which have large current capacity and low power loss will be needed. In this paper we have studied breakdown voltage properties of paper/liquid composite insulating system for HTS cable insulation. And we measured the dielectric loss(tan$\delta$) of mini-model cable. From results, the insulation paper-ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

국내 섬유질 단열재의 내화성능에 관한 연구 (A Study on the Fire Resistance of Korean Cellulose Insulation)

  • 권영철;황정하;유형규
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

소수력발전기 절연특성분석 (Analysis of Insulation Characteristic for Small Hydro Generator)

  • 오봉근;장정호;이광호;강동식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2008
  • Electrical insulation of small hydro generator stator winding is one of the most important parts in generator facilities. Some stator winding insulation problems can be identified through analysis of insulation diagnostic test. So, Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of small hydro generator. This paper presents case studies of insulation failure in generator stator windings and the results of insulation diagnostic test for small hydro generator stator windings. Especially, Conducting the insulation diagnostic test before the generator installed in site is very important process to keep the good insulation condition in service.

  • PDF

Comparative Study on Conductivity and Moisture Content Using Polarization and Depolarization Current (PDC) Test for HV Insulation

  • Jamail, N.A.M.;Piah, M.A.M.;Muhamad, N.A.;Kamarudin, Q.E.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.7-11
    • /
    • 2014
  • The Polarization and Depolarization Current (PDC) measurement is an efficient and effective diagnostic technique based on time domain measurement, for evaluating the high voltage insulation condition. This paper presents a review and comparison results from several published papers on the application of the PDC method to finding the conductivity and moisture content of various types of insulators. For solid insulation, the study was focused on cable insulation, electric machine stator insulation, and paper insulator in transformer insulation with different conditions. For liquid insulation, the review and comparison was done on biodegradable and mineral transformer oils, with fresh oil condition, and aged condition. The results from previous researchers tests were complied, analyzed and discussed, to evaluate the application of the PDC method to monitor the conductivity and moisture of HV equipment insulation systems. From the review results, the PDC technique successfully gives an indication of the conductivity and moisture level of high voltage insulation.

SOFC용 고온 적층 단열재의 해석적 고찰 (An Analysis Using Numerical Model of Composite Multi-Layer Insulation for SOFC)

  • 최종균;황승식;최규홍
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.540-548
    • /
    • 2019
  • This study was conducted to develop insulation for solid oxide fuel cell (SOFC). The developed insulation is based on the lamination technology and the radiation shielding technology of the satellite insulation. The insulation material is consisting of insulation material for conduction resistance, spacer, and radiation shielding material. The experimental apparatus consisting vacuum bell jar, pump, heater and temperature recording device has developed to verify the performance of the insulation. The experimental values were used as reference data for the modeling development. In this paper, heat transfer is assumed to be one- dimensional phenomena for the prediction of insulation performance and internal temperature distribution in high temperature region of SOFC. The developed model was used to compare the performance difference of insulation types according to composition materials. The analysis result shows that the insulation including spacer and radiation shielding has better heat insulation performance than other cases. In this study, the thickness reduction effect of about 20% was shown compared to the insulation including only conductive material. It is noted that the radiant shielding material should be carefully selected for durability, because SOFC insulation should be used for a long time at high temperature.

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.

배관감육 관리를 위한 고정식 및 탈착식 보온재 설치 경제성 분석 (Economic Analysis of Installing Fixed and Removable Insulation for Pipe Wall Thinning Management)

  • 황경모;윤훈
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.320-325
    • /
    • 2016
  • To perform ultrasonic testing (UT) thickness measurement of the secondary side piping installed in nuclear power plants, the insulation for preventing heat loss should be removed. The type of insulation can be divided into fixed and removable insulation. Fixed and removable insulation have their own strengths and weaknesses. Removable insulation has been installed in the components susceptible to wall thinning caused by FAC and erosion from Shin-Kori unit 1, which commenced its commercial operation in 2011. In this paper, the number of repeated inspections of components and the number of replacements of fixed insulation were estimated and a more economical way was identified based on the manufacturing and installation costs for fixed and removable insulation.