• Title/Summary/Keyword: Insulation Design

Search Result 897, Processing Time 0.028 seconds

Three-Dimensional Insulation Design Algorithm Using NURB Surface and Its Application (NURB곡면을 이용한 3차원 절연설계 알고리즘과 그 응용)

  • Lee, B.Y.;Myung, S.H.;Han, I.S.;Park, J.K.;Kim, E.S.;Min, S.W.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1684-1687
    • /
    • 1997
  • In this paper, a three-dimensional algorithm for the insulation design of the high-voltage equipment is presented. In general, the insulation design consists of two steps. They are electric field calculation and correction of the shape to be designed. In the proposed algorithm, the combination method of charge simulation and surface charge simulation is used to calculate the three-dimensional electric fields. As for the correction of the shape, indirect control provided by rational B-spline is more useful than direct control. The use of rational B-spline reduces in the number of design variables and garrantees the smooth curvature of the designed shape. The proposed algorithm is applied to the design of the shape of the shield ring which has been designed by the method of trial and error.

  • PDF

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL (초전도 한류기의 턴간 절연특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

Consumer recognition and mechanical property comparison of wetsuit material for diving (다이빙용 웨트수트(wetsuit) 소재에 대한 소비자 인식조사와 물성 비교)

  • Sang, Jeong Seon;Oh, Kyung Wha
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.4
    • /
    • pp.163-174
    • /
    • 2018
  • Consumer and property evaluation of wetsuit materials were conducted to obtain useful data for developing competitive products that meet consumer expectations and improving industrial competitiveness. Data were collected through online surveys of 213 domestic consumers who have experienced wearing wetsuit among marine leisure activities. Five types of commercial wet suit materials by brand and four types of commercial wet suit materials with the same quality by thickness were collected. Then, their physical properties, salt water resistance and thermal insulation rate were evaluated and compared. As a result, the most commonly used wetsuit material is 3 to 5 mm thick, and the basic jersey material is bonded on both sides. As a processing for imparting functionality, processing for improving warmth and reducing surface resistance are most frequently used. Consumers often feel uncomfortable when wearing a wetsuit, such as wearing comfort, weight, ease of movement, stretchability, and clothing pressure, which are different from those of casual wear. Also, mechanical strength and warmth were considered to be the most important criteria for selection of wetsuit material for purchase or rental. The mechanical properties of brand A and B were better than those of brand C, D, and E. Resilience and thermal shrinkage were better in brand C, D, and E. On the other hand, there was no significant difference in the physical properties due to the difference in thickness of the material at the same quality. Also, it was found that the thicker the material, the more stable it is in the heat. Brand A and B had superior salt water resistance than brand C, D, and E. In the thermal insulation test, brand A and B showed better insulation characteristics than brand C, D, and E, but the types of bonded fabric and surface finishing of materials were thought to have affected. In comparison of the thickness, the thicker the materials, the better the salt resistance and the thermal insulation.

Analysis of Heat Transfer Characteristics Based on Design Factors for Determining the Internal Geometry of Metal Insulation in Nuclear Power Plant (원전용 금속단열재의 내부 형상결정을 위한 설계인자 별 열전달 특성 분석)

  • Song, Ki O;Yu, Jeong Ho;Lee, Tae Ho;Jeon, Hyun Ik;Ha, Seung Woo;Cho, Sun Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1175-1181
    • /
    • 2015
  • A heat insulating material used in the industrial site normally derives its heat insulating performance by using a low thermal conductivity material such as glass fiber. In case of the metal insulation for nuclear power plant, in contrast, only TP 304 stainless steel foil having high thermal conductivity is the only acceptable material. So, it is required to approach in structural aspect to ensure the insulation performance. In this study, the design factors related to the metal insulation internal structure were determined considering the three modes of heat transfer, i.e., conduction, convection, and radiation. The analysis of heat flow was used to understand the ratio of the heat transfer from each factor to the overall heat transfer from all the factors. Based on this study, in order to minimize the convection phenomenon caused by the internal insulation, a multiple foil was inserted in the insulation. The increase in the conduction heat transfer rate was compared, and the insulation performance under the three modes of heat transfer was analyzed in order to determine the internal geometry.

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

Effects of Air Velocity on the Thermal Insulation of Winter-padded Clothing Ensembles at 10℃ Air Temperature -Comparison of Human Wear Trials with a Thermal Manikin- (10℃ 환경에서 기류가 겨울철 패딩 의류의 한 벌 보온력에 미치는 영향 -인체 착용 및 서멀마네킹 측정 비교-)

  • Baek, Yoon Jeong;Cho, Kayoung;Hong, Yujin;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.4
    • /
    • pp.703-713
    • /
    • 2021
  • This study was to investigate the thermal insulation of clothing ensembles, including padded jackets with two different filling types. Thermal insulation of the ensemble was measured using a thermal manikin in four conditions (10℃, 30% RH and 20℃, 50% RH with an air velocity of less than 0.15 m·s-1 and 1.5 m·s-1). Ten males participated at 10℃ and 30% RH with an air velocity of less than 0.15 m·s-1 and 1.5 m·s-1. The results showed that the polyester ensemble was warmer than a goose down ensemble in 0.15 m·s-1 conditions and the goose down ensemble had greater thermal insulation than the polyester ensemble at an air velocity of 1.5 m·s-1. Thermal insulation was reduced 5-7% when temperature decreased 10℃ and reduced 40-50% when air velocity reached 1.5 m·s-1 for both ensembles. Thermal insulation of the ensemble in human trials decreased more than a thermal manikin at 10℃, 30% RH with an air velocity of 1.5 m·s-1. Lower temperatures and human trials were effective in identifying the properties of the thermal insulation by filling types even though there were restrictions on the general application because of two types of a clothing ensemble.

Air-containing Multi-functional Jacket Design Utilizing Modular Systems - Focused on Cushioning, Heat Insulation and Portability - (모듈러 시스템을 이용한 공기주입형 다기능 재킷 디자인 - 쿠션, 보온, 휴대 기능을 중심으로 -)

  • Son, Sue-Min
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.2
    • /
    • pp.222-237
    • /
    • 2012
  • Air-containing fashion, which can offer diverse functions through the inflow and outflow of air, is highly relevant in today's mobile society, where people are experiencing a wider range of environments. This study attempts to suggest the possibility of air-containing multi-functional fashion that could continuously be utilized by developing a design for an air-containing jacket using modular systems. In this research, the modular systems in architecture and furniture design were referenced through a review of the literature for the purpose of establishing modular systems in fashion. Functions relevant to the mobility of today's society are derived from the results of advanced research and applied to the design of modules of the jacket. The modules are integrated through the modular systems. The folding and unfolding structure in architecture and furniture is applied as a folding system in fashion, the vertical accumulation structure as a layering system, and the horizontal integration structure as a combining system, and in addition, the containing system has emerged in fashion. Each module is designed to fulfill certain functions, such as cushioning, heat insulation, and portability. The folding system is utilized in designing the cushion module to support the neck and back of a wearer by making its hood and hem fold in the back. The application of a layering system was suggested by making the vest, combined with the neck cushion and back cushion via the combining system, layered with its insulation module. By applying the combining system, the hood that includes the neck cushion, the skirt that includes the back cushion, the body that includes the insulation module, and the sleeves can be connected and separated by a zipper. The applicability of this concept was proven by applying a developed design to an actual item.

Analysis on Freezing Reduction of Road Tunnels with Heat Insulation Method during Winter (단열공법이 적용된 겨울철 도로터널의 동결저감 효과 분석)

  • Son, Hee-Su;Jun, Kyoung-Jea;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.17-27
    • /
    • 2017
  • Gangwon province which is located in northeast of Korea is the coldest region where average daily temperature is below zero during winter while the other regions are above zero. However, there have been insufficient researches on the insulation design and the effect of the insulation on the freezing damages, even though freezing damages were reported consistently in the lining of road tunnel during winter. In this study, to investigate the effect of insulations on the reduction of freezing damages, numerical analysis was performed considering geotechnical and meteorological characteristics in Gangwon province during winter. As a result, it was found that thickness of concrete and shotcrete in lining had negligible effect on the freezing depth while the insulation had significant effect on it. In addition, because the freezing depth is greatly affected by the thermal conductivity of the ground behind the lining in the period of cold weather, these effects should be considered in the estimation of the insulation thickness.

Gender Difference of Self-health Image and Actual Wearing Conditions in University Students (성별에 따른 대학생의 자기 건강 이미지와 착의 실태 차이)

  • Chung, Ihn Hee;Kweon, Soo Ae;Lee, Yun Jung;Lee, Joo-Young;Jeong, Woon Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.1
    • /
    • pp.64-75
    • /
    • 2013
  • This study suggests basic data on optimum thermal insulation for spring wear through an investigation of subjective thermal sensation, self-health image and actual wearing conditions. A survey of university students using a self-administered questionnaire was conducted to collect data on subjective thermal sensation, self-health image, wearing conditions, demographics and physical characteristics. The variable of wearing conditions was measured as the response to the clothing they were wearing. Garment items (26 types for males and 41 types for females) were suggested and the items worn by the students were converted into the thermal insulation values for clothing. The main results are as follows. As for the body type perception, males perceived themselves as not fat while females perceived themselves as not thin. As for the health perception, males perceived themselves healthier than females. As for the climate adaptability perception, females were more sensitive to cold than males. The average thermal insulation of clothing was 0.97clo (0.34-1.95clo) with higher insulation for males than females. Students were more sensitive to the cold when their BMI was lower, their body surface area per body weight was larger, and the more they perceived themselves as not healthy. There was a significant correlation between the self-health image of sensitiveness to cold and the thermal insulation of clothing. The results were synthetically discussed in terms of environmental physiology.